Drive Medical Design 14027 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Drive Medical Design 14027, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Drive Medical Design 14027 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Drive Medical Design 14027. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Drive Medical Design 14027 should contain:
- informations concerning technical data of Drive Medical Design 14027
- name of the manufacturer and a year of construction of the Drive Medical Design 14027 item
- rules of operation, control and maintenance of the Drive Medical Design 14027 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Drive Medical Design 14027 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Drive Medical Design 14027, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Drive Medical Design service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Drive Medical Design 14027.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Drive Medical Design 14027 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Med- Aire 8” Alternating P ressure Mattress R eplacement System With Low Air Loss Item # 14027 ww w . drivemedical. com OPERA TOR’S MANU AL[...]

  • Page 2

    2 T ABLE OF CONTENT S IMPORT ANT SAFEGUARDS............................................................................................................ 3 ST A TEMENTS & SYMBOLS..............................................................................................................4 INTRODUCTION..............................................[...]

  • Page 3

    3 IMPORT ANT S AFEGU ARDS When using electrical products, especially when childr en are pr esent, basic safety precautions should always be followed, including the following READ ALL INSTRUCTIONS BEFORE USING DANGER T o r educe the risk of electrocution: • Alwaysunplugthisproductimmediatelyafteruse. • Donotusewh[...]

  • Page 4

    4 Note, caution, w ar ning & danger statements NOTE Indicates some tips or some information users should be aware of. CAUTION Indicates correct operatingor maintenance procedure in order to prevent damageto or destructionof theequipmentorotherproperty . W ARNING/DANGER Callsatten[...]

  • Page 5

    5 INTRODUCTION This manual should be used for the initial set up of the system and for refer ence purposes. GENERAL The14027seriesisa highqualityandaffor dableair supportsur facesuitablefor mediumandhigh-risk pressur e ulcer tr eatment. It has been specically designed for[...]

  • Page 6

    6 P A CKA GE C ONTENT Check inside the package. If any of the following items should be missing or damaged, please contact yourlocaldealerorservicecenterforreplacementimmediately . PUMP Make sure the type of pump is identical to which you pur chased. Functionalitiesvaryfrommodeltomodel. MA TTRESS Cell[...]

  • Page 7

    7 PUMP The functions of the pump for the 14027 series are described below . P ower Switc h (1) The switch is at the right side of the pump. T urn ON/OFF the power , the pump will star t/stop operation. Pressure-adjust Knob (2) T urnthesoft/r mknobtosetacomfor tablepr essurelevel. Normal Pressure Indicator (3) [...]

  • Page 8

    8 INS T ALLA TION Step 1 Placethemattressatlyonthebedframe. The inationtube should be towar ds the foot endso that it canbe connected to theination nozzles on the pump. Step 2 Y oumayplaceathincottonsheetoverthequiltedmattress?[...]

  • Page 9

    9 GROUNDING INS TRUCTIONS Thisproductshouldbegrounded.Inthe eventofan electricalshor tcircuit,gr ounding r educes therisk of electric shock by pr oviding an escape wire for the electric current. This pr oduct is equipped with a cord that contain[...]

  • Page 10

    10 OPERA TION Always read the operating instructions befor e use. GENERAL This product is designed to provide maximum comfor t to patients. Make sure that you operate this product in apr oper wayto optimizing itsvalue. Here we provide some generalinformation?[...]

  • Page 11

    11 Alwa ys read the operating instructions before use. Please follow instructions below for detailed operating procedur e of each type. Step 1 T urn on the power . The indicator light on the power switch will come on. The pump starts to pump air into the mattress. TheLowPressur eindicator(yelloworred)willcomeonasin?[...]

  • Page 12

    12 Alwa ys read the operating instructions before use. CPR FUNCTION When there is an emergency to perform CPR on the patient, pull the CPR strap at the head section of themattresstor eleasetheairquicklyfromthemattr ess. TheCPRstrapislocatedatthefrontright-handsideofthemattr ess[...]

  • Page 13

    13 In this section, we describe the procedur es to clean and decontaminate the pump. It is impor tant to follow these procedur es before using the system again. Thecleaningtaskisrequir edatleastonceaweektomaintainpersonalhygiene. PUMP • DONOTimmerseorsoakthepump. • Check[...]

  • Page 14

    14 • Laythemattressoutatandupsidedown. • Roll from the foot end towar ds the head end; the foot-end strap can then be stretched around the  rolledmattr esstopreventunr olling. • Donotfold,creaseorstackthemattr[...]

  • Page 15

    15 Thepumpdoesn’twork 1. Checkiftheplugisinsertedr mlyintotheoutlet. 2. T urn on the power switch again. • If thepower indicatoris ONand the pumpstill doesn’t work, contact your local dealer immediately . • If the power indicator is O[...]

  • Page 16

    16 SPECIFIC A TIONS SYSTEM ITEM SPECIFICA TIONS Classication ClassI;IPX0;AP/APGNO;T ypeBF Applied Part Mattress InputRating AC120V60Hz;12W ,1A FuseRating 250V ,T1A Pressur eRange 30~60mmHg Cycle Time 12 min/50Hz, 10 min/60Hz Dimensions(Pump)?[...]

  • Page 17

    17 Y our Drive brand product is warranted to be fr ee of defects in materials and workmanship for 12 months of the original consumer purchaser . This device was built to exacting standards and car efully inspected prior to shipment. This12 monthLimited W ar[...]

  • Page 18

    18 NO TES[...]

  • Page 19

    19 NO TES[...]

  • Page 20

    99SeaviewBoulevard Port Washington, NY 11050 Phone:516-998-4600 Fax:516-998-4601 www .drivemedical.com[...]