A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Drive Medical Design 14027, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Drive Medical Design 14027 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Drive Medical Design 14027. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Drive Medical Design 14027 should contain:
- informations concerning technical data of Drive Medical Design 14027
- name of the manufacturer and a year of construction of the Drive Medical Design 14027 item
- rules of operation, control and maintenance of the Drive Medical Design 14027 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Drive Medical Design 14027 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Drive Medical Design 14027, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Drive Medical Design service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Drive Medical Design 14027.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Drive Medical Design 14027 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Med- Aire 8” Alternating P ressure Mattress R eplacement System With Low Air Loss Item # 14027 ww w . drivemedical. com OPERA TOR’S MANU AL[...]
-
Page 2
2 T ABLE OF CONTENT S IMPORT ANT SAFEGUARDS............................................................................................................ 3 ST A TEMENTS & SYMBOLS..............................................................................................................4 INTRODUCTION..............................................[...]
-
Page 3
3 IMPORT ANT S AFEGU ARDS When using electrical products, especially when childr en are pr esent, basic safety precautions should always be followed, including the following READ ALL INSTRUCTIONS BEFORE USING DANGER T o r educe the risk of electrocution: • Alwaysunplugthisproductimmediatelyafteruse. • Donotusewh[...]
-
Page 4
4 Note, caution, w ar ning & danger statements NOTE Indicates some tips or some information users should be aware of. CAUTION Indicates correct operatingor maintenance procedure in order to prevent damageto or destructionof theequipmentorotherproperty . W ARNING/DANGER Callsatten[...]
-
Page 5
5 INTRODUCTION This manual should be used for the initial set up of the system and for refer ence purposes. GENERAL The14027seriesisa highqualityandaffor dableair supportsur facesuitablefor mediumandhigh-risk pressur e ulcer tr eatment. It has been specically designed for[...]
-
Page 6
6 P A CKA GE C ONTENT Check inside the package. If any of the following items should be missing or damaged, please contact yourlocaldealerorservicecenterforreplacementimmediately . PUMP Make sure the type of pump is identical to which you pur chased. Functionalitiesvaryfrommodeltomodel. MA TTRESS Cell[...]
-
Page 7
7 PUMP The functions of the pump for the 14027 series are described below . P ower Switc h (1) The switch is at the right side of the pump. T urn ON/OFF the power , the pump will star t/stop operation. Pressure-adjust Knob (2) T urnthesoft/r mknobtosetacomfor tablepr essurelevel. Normal Pressure Indicator (3) [...]
-
Page 8
8 INS T ALLA TION Step 1 Placethemattressatlyonthebedframe. The inationtube should be towar ds the foot endso that it canbe connected to theination nozzles on the pump. Step 2 Y oumayplaceathincottonsheetoverthequiltedmattress?[...]
-
Page 9
9 GROUNDING INS TRUCTIONS Thisproductshouldbegrounded.Inthe eventofan electricalshor tcircuit,gr ounding r educes therisk of electric shock by pr oviding an escape wire for the electric current. This pr oduct is equipped with a cord that contain[...]
-
Page 10
10 OPERA TION Always read the operating instructions befor e use. GENERAL This product is designed to provide maximum comfor t to patients. Make sure that you operate this product in apr oper wayto optimizing itsvalue. Here we provide some generalinformation?[...]
-
Page 11
11 Alwa ys read the operating instructions before use. Please follow instructions below for detailed operating procedur e of each type. Step 1 T urn on the power . The indicator light on the power switch will come on. The pump starts to pump air into the mattress. TheLowPressur eindicator(yelloworred)willcomeonasin?[...]
-
Page 12
12 Alwa ys read the operating instructions before use. CPR FUNCTION When there is an emergency to perform CPR on the patient, pull the CPR strap at the head section of themattresstor eleasetheairquicklyfromthemattr ess. TheCPRstrapislocatedatthefrontright-handsideofthemattr ess[...]
-
Page 13
13 In this section, we describe the procedur es to clean and decontaminate the pump. It is impor tant to follow these procedur es before using the system again. Thecleaningtaskisrequir edatleastonceaweektomaintainpersonalhygiene. PUMP • DONOTimmerseorsoakthepump. • Check[...]
-
Page 14
14 • Laythemattressoutatandupsidedown. • Roll from the foot end towar ds the head end; the foot-end strap can then be stretched around the rolledmattr esstopreventunr olling. • Donotfold,creaseorstackthemattr[...]
-
Page 15
15 Thepumpdoesn’twork 1. Checkiftheplugisinsertedr mlyintotheoutlet. 2. T urn on the power switch again. • If thepower indicatoris ONand the pumpstill doesn’t work, contact your local dealer immediately . • If the power indicator is O[...]
-
Page 16
16 SPECIFIC A TIONS SYSTEM ITEM SPECIFICA TIONS Classication ClassI;IPX0;AP/APGNO;T ypeBF Applied Part Mattress InputRating AC120V60Hz;12W ,1A FuseRating 250V ,T1A Pressur eRange 30~60mmHg Cycle Time 12 min/50Hz, 10 min/60Hz Dimensions(Pump)?[...]
-
Page 17
17 Y our Drive brand product is warranted to be fr ee of defects in materials and workmanship for 12 months of the original consumer purchaser . This device was built to exacting standards and car efully inspected prior to shipment. This12 monthLimited W ar[...]
-
Page 18
18 NO TES[...]
-
Page 19
19 NO TES[...]
-
Page 20
99SeaviewBoulevard Port Washington, NY 11050 Phone:516-998-4600 Fax:516-998-4601 www .drivemedical.com[...]