Go to page of
Similar user manuals
-
Stove
Drolet DB03010
2 pages 0.45 mb -
Stove
Drolet HT-2000
28 pages 0.4 mb -
Stove
Drolet gemini 1500
2 pages 0.22 mb -
Stove
Drolet COMPAK EPA EXEMPT 45109A
19 pages 0.48 mb -
Stove
Drolet HT1200
28 pages 0.61 mb -
Stove
Drolet DB05345
2 pages 0.28 mb -
Stove
Drolet ULC S627
34 pages 0.59 mb -
Stove
Drolet DB03070
2 pages 5.21 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Drolet 2000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Drolet 2000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Drolet 2000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Drolet 2000 should contain:
- informations concerning technical data of Drolet 2000
- name of the manufacturer and a year of construction of the Drolet 2000 item
- rules of operation, control and maintenance of the Drolet 2000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Drolet 2000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Drolet 2000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Drolet service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Drolet 2000.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Drolet 2000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
OWNER`S MANUAL DROLET EPA WOODSTOVES SIBERIAN-1200 SIBERIAN-1600 SIBERIAN-2000 US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVES Vérified and tested following ULC S627 et UL 1482 Standards by: Intertek Testing Services READ AND KEEP THIS MANUAL FOR REFERENCE Manufactured by : STOVE BUILDER INTERNATIONAL INC. . 1700, Léon-Harmel, Qu[...]
-
Page 2
1 TABLE OF CONTENTS INTRODUCTION ............................................................................................................... 2 TECHNICAL SPECIFICATIONS ....................................................................................... 3 ASSEMBLY ...............................................................................[...]
-
Page 3
2 INTRODUCTION SBI INC ., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wishes to help you get maximum satisfaction from your wood stove. In the pages that follow, we will give you advice on wood heating and controlled combustion as well as technica l specifications regarding inst[...]
-
Page 4
3 TECHNICAL SPECIFICATIONS SIBERIAN-1200 SIBERIAN-1600 SIBERIAN-2000 Combustion Type: Wood Wood Wood Recommended Surface 600 à 1 200 ft 2 (56 à 112 m 2 ) 900 à 1 600 ft 2 (84 à 149 m 2 ) 1 000 à 2 000 ft 2 (93 à 186 m 2 ) Heating Capacity : E.P.A : 36 000 BTU/h (10,5kW) 40 000 BTU/h (11,7 kW) 60 200 BTU/h (17,6 kW) Real : 45 000 BTU/h (13,2 k[...]
-
Page 5
ASSEMBLY PEDESTAL AND DECORATIVE SIDEWALL INSTALLATION Figure 1 : SIBERIAN-1200 and 1600 Pedestal Installation : 1. Remove all bricks and insulations in the appliance. 2. Slowly, lay down the stove on his back. 3. Install legs or the pedestal with the supplied nuts and bolts. Stand up the stove and plac e it with the required clearances. Note that [...]
-
Page 6
BRICKS INSTALLATION (SIBERIAN-1200) Figure 3: SIBERIAN-1200 • Refractory bricks are to be installed according to figure 4. • In both stoves, the baffle brick must be pushed as close to the front as possible onto its metallic support. • The upper bricks (2) must lay on the vertical bricks (4) grove • Note that a plain brick is supplied inste[...]
-
Page 7
BRICKS AND INSULATION INSTALLATION (SIBERIAN-1600) 1. Remove from the stove all bricks and insulation. 2. Install all side bricks (12 x 4 1/2" x 9") 3. Install the back bricks (6 x 4 1/2" x 9") 4. Install the bottom bricks (4 x 4 1/2" x 9") + (2 x 6" x 7"). 5. Install the "T" shape support and the b[...]
-
Page 8
BRICK AND INSULATION INSTALLATION (SIBERIAN 2000) The stove is normally supplied with secondary air t ubes in position. To install the baffle bricks and white ceramic insulation, it’s necessary to re move the two front secondary air tubes. First place only one baffle brick and one white ceramic in sulation. Use the same method to put the other ba[...]
-
Page 9
AIR TUBES INSTALLATION (SIBERIAN 2000): The secondary air tubes are painted different co lours . The back tube is yellow, the middle one is red and the front is unpainted. Before inst alling, make sure the locating holes in the tubes (holes near one end of the tube) are on the left side. Insert one tube in the right side air channel and slide it to[...]
-
Page 10
DOOR ADJUSTMENT In order for your stove to operate properly, the door shoul d be adjusted periodically to provide an air tight fit. To adjust: • Remove the lock pin (spring pin) by pulling and turning it using pliers ("wise grip") • Turn the handle counter clock wise one turn to increase pressure • Re-install the lock pin (spring pi[...]
-
Page 11
THE BENEFITS OF INSTALLING A BLOWER A blower can be installed at t he back of your DROLET stove. This option is necessary if you wish to redistribute into a room the heat trapped at the back of your stove. By forcing hot air toward the front, the blower enables you to extend the radiation power of your stove. You can purchase this option through yo[...]
-
Page 12
11 INSTALLATION SAFETY NOTICE • I F THIS STOVE IS NOT PROPERLY INSTALLED , A HOUSE FIRE MAY RESULT . T O REDUCE THE RISK OF FIRE , FOLLOW THE INSTALLATION INSTRUCTIONS . F AILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE , BODILY INJURY , OR EVEN DEATH . • C ONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR F IRE OFFICIALS ABOUT RESTRICTI[...]
-
Page 13
FLOOR PROTECTOR Your wood stove should be placed on a non-com bustible surface. The floor protector should be under the stove, eighteen inches bey ond the front and eight inches beyond each side of the fuel loading and as h removal opening. If there is a horizontal section of chimney connector, the floor protector should go under it and two inches [...]
-
Page 14
CLEARANCES It is of utmost importance that the clearanc es to combustible material be scrupulously respected upon installation of the stove you hav e selected. Refer to the tables below : Figure 8: Clearances to combustibles Single wall pipe / Double w all pipe CANADA A B C D E F SIBERIAN-1200 15/10 8/8 7/6 20.4/15.4 20/20 19.4/18.4 SIBERIAN-1600 1[...]
-
Page 15
14 REDUCED CLEARANCES You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. These heat radiation shields must be installed permanently, and can include sheet metal, a rigid non-co mbustible sheet or a masonry wall. Clearances of not less than 1" (25 mm) and not more than 3" (7[...]
-
Page 16
15 CHIMNEY Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a factory built chimney, it must co mply with UL 103 or ULC S629 standards; therefore it must be a Type HT (2100°F). It is extremely important that it be installed according to the manufacturer's specifications. If you are using a masonry chi[...]
-
Page 17
CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have t he same diameter as the stove outlet. If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draught. The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0.021" or 0.53 m[...]
-
Page 18
TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY: ROOF FLASHING 18" CLEARANCE WALL SUPPORT WALL RADIATION SHIELD RAIN CAP Wall installation CEILING SUPPORT RADIATION SHIEL D Vertical installation 17[...]
-
Page 19
MASONRY CHIMNEY: Cl a y l i n e r Thim b l e C l ean out door 18[...]
-
Page 20
FACTORY BUILT THIMBLE: 19[...]
-
Page 21
BRICK THIMBLE: 20[...]
-
Page 22
21 WOODSTOVE UTILIZATION Your heating unit was designed to burn wood onl y; no other materials should be burnt. Wastes and other flammable materials should not be burnt in your wood stove. Any type of wood may be used in your stove, but specif ic varieties have better energy yields than others. Please consult the following table in order to make th[...]
-
Page 23
22 Smaller pieces of wood will dry faster. All l ogs exceeding 6" in diameter should be split. The wood should not be stored directly on the ground. Air should circulate through the cord. A 24" to 48" air space should be left between each row of logs, which should be placed in the sunniest location possible. The upper layer of wood s[...]
-
Page 24
HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of com bustion you want for each given situation. The wood will burn slowly if the wood stove air intake control is adjusted to reduce the oxygen supply in the combustion chamber to a minimum. On t he other hand, wood will burn q[...]
-
Page 25
24 RELOADING Once you have obtained a good bed of embers, y ou should reload the unit. In order to do so, open the air controls to maximum a few seconds prior to opening the stove's door. Then proceed by opening the door very slowly; open it one or two inches for 5 to 10 seconds, before opening it completely to in crease the draught and t hus [...]
-
Page 26
25 ASH DISPOSAL Ashes should be removed from the stove ever y few days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold, such as in the morning. Always dispose of ashes in a metal container wit h a tight fitting lid. Plac e this container on a non combustible floor or on the ground, well away from all combustible mate[...]
-
Page 27
26 MAINTENANCE Your Drolet stove is a high efficiency stove and therefore require li ttle maintenance. It is important to perform a visual inspection of the stove every time it is emptied, in order to insure that no parts have been damaged, in which case repairs must be performed immediately. GLASS • Inspect the glass regularly in order to detect[...]
-
Page 28
1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e- ma il : te ch @d ro le t. ca we b si te : www. dro le t. ca LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the orig inal consumer purchaser and is not transferable. This warranty covers brand new products only, which have not [...]