A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Drolet COMPAK EPA EXEMPT 45109A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Drolet COMPAK EPA EXEMPT 45109A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Drolet COMPAK EPA EXEMPT 45109A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Drolet COMPAK EPA EXEMPT 45109A should contain:
- informations concerning technical data of Drolet COMPAK EPA EXEMPT 45109A
- name of the manufacturer and a year of construction of the Drolet COMPAK EPA EXEMPT 45109A item
- rules of operation, control and maintenance of the Drolet COMPAK EPA EXEMPT 45109A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Drolet COMPAK EPA EXEMPT 45109A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Drolet COMPAK EPA EXEMPT 45109A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Drolet service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Drolet COMPAK EPA EXEMPT 45109A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Drolet COMPAK EPA EXEMPT 45109A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    REA D A ND KEEP THIS MA NUA L FOR REFERENC E 45109A 2010 - 09 - 22 INSTRUCTIONS & OPERATIONS MANUAL DROLET COMPAK EPA EXEMPT US ENVIRONMENTAL PROT ECTION AGENCY 28A CERTIFIED W OODST OVES Verified and tested follow ing UL 1482 Standards by : Manufactured by : S T OVE BUILDER INTERNA T IONA L INC. 1700, Leon -Harm el, Quebec (Quebec) G1N 4R9 Tel[...]

  • Page 2

    1 TA BLE OF CONTENTS INTRODUCTION ................................................................................................................. 2 ASSEMBLY ................................................................ ......................................................... 3 INSTALLA TION ....................................................[...]

  • Page 3

    2 IN TR OD UC TI ON ST OVE BUILDER INTERNATIONAL INC., one of th e most imp ortant wood stove an d fireplace manuf acturers in Canada, congratulates you on your purchase an d wishes to help you get maximum satisf action from your wood stove. In th e pages that f ollow, we will give you ad vice on wood heating and controlled co mbustion as well as t[...]

  • Page 4

    3 A S SE MB LY Legs installation: Position the stove on its back and screw the legs in place with 8 screws, 8 bolts, an d 8 washers; A sh lip Install ation: Screw in place w ith 2 bolts, 2 screws, and 2 washers.[...]

  • Page 5

    4 Cast iron flue collar i nstallation: 1. Peel of f the tape from the back of the gasket and attac h the gasket to the rope groove at the back o f the f lue collar; 2. Mount flue collar on top of the stove. Make sure tha t the damper ho les on each side o f the f lue collar are parallel to th e back of the stove; 3. Fix the flue collar with the har[...]

  • Page 6

    5 IN ST A LLA TIO N SA FETY NOTICE I F THIS S TOVE IS NOT PROPERLY INSTALLED , A HOUSE FIRE MAY RESULT . T O REDUCE THE RISK OF FIRE , FOLLOW THE INSTALLATION INSTRUCTIONS . F AILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE , BODILY INJURY , OR EVEN DEATH . C O NSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS A BOUT RESTRICTIO[...]

  • Page 7

    6 C LE A R A N CE S FR OM C OMB US T IB LE S It is o f outmost importan ce tha t the clearanc es to com bustible m aterials be scrupulously respected up on installation of the stove you have selected. Refer to the t ables below : Single pipe / Double pipe A B C D E F 29” 30” 39” 34- 3/4” 22” 32” Floor to ceiling height m ust be at lea s[...]

  • Page 8

    7 C HI MNE Y Your wood stove may be hooked up with a factory built o r masonry chimney. If you are using a f actory built chimney, it must comply with UL 103 sta ndards; th erefore it must be a Type HT (210 0°F). It is extremely imp ortant that it b e installed according to the manuf acturer's specification s. If you are using a masonry ch im[...]

  • Page 9

    8 C HI MNE Y CO NN E CT OR ( ST OV E PI PE ) The stove pipe must be m ade of aluminized or cold roll steel with a minim um thickness of 0.021" o r 0.53 mm. I t is strictly forbidden to u se galvaniz ed steel. Your smoke pipe should be assembled in such a way th at the mal e section of the pipe faces down. Attach each of the sections to o ne an[...]

  • Page 10

    9 T YP IC A L IN ST A LL A T IO NS FA CTORY BUILT CHIMNEY: ROOF FLASH ING 18 " CL EARAN CE WAL L SU PPORT WAL L RADI AT ION SHIE LD RAIN CAP Wall installa tion CEIL ING SUP PORT RADI AT ION S HIEL D Vertical install ation[...]

  • Page 11

    10 MA SONRY CHIMNEY: Cl a y li ne r T hi m b le Cl e an out door[...]

  • Page 12

    11 FA CTORY BUILT THIMBLE:[...]

  • Page 13

    12 BRICK THIMBLE:[...]

  • Page 14

    13 WO OD S TO VE U TIL IS A TI ON Your h eating unit was designed to b urn wood only; no other m aterials should be b urnt. W aste s and othe r f lammable mate rials should no t be bu rnt in your wood sto ve. Any type of wood may be used in your sto ve, but specif ic varieties have better en ergy yields th an others. Plea se consult the f ollowing [...]

  • Page 15

    14 Smaller piece s of wood will dry faste r. All logs exceeding 6" in diameter should be split. The wood sho uld not be sto red directly on the ground. Air should circulate through the cord. A 24 " to 48" a ir space sh ould be left between each row of logs, which should be placed in the su nniest location possible. Th e u pper lay e [...]

  • Page 16

    15 A SH D IS PO SA L Ashes sh ould be remo ved from the stove every few days or when ashes get to 2 to 3 inches deep . Alway s e mpty the stove when it is cold, such a s in the morning. Always dispose of ashes in a metal containe r with a tight fitting lid. Place this con tainer on a non combustible floo r or on the ground, well a w a y f rom a ll [...]

  • Page 17

    16 A IR C IR CU LA TI ON S YS T EM In order to improve air circulation in the room where the wood sto ve is installed, certain options are a vailable for specific sto ve models. Blowe r: A variable spe ed-control blower is available. T he part numbe r is AC02050. Thermodisc: The thermo disc is installed on th e blower's electrical supply cord,[...]

  • Page 18

    17 WA RNING: N EVERS OPERATE THE STOVE W ITHOUT A GASKET OR W ITH A BROKEN ONE . D AMAGE TO THE STOVE OR EVEN HOUSE FIRE MAY RESULT PA IN T Only clean your stove with a dry soft clothe th at will not harm the paint f inish. If the paint beco mes scrat ched or damaged, it is p ossible to give your wood stove a brand new loo k, by repainting it with [...]

  • Page 19

    18 DR O LE T LI MI TE D LI FE TI ME WA RRA N TY The warranty of the man ufacturer e xtends only to the original consumer purchaser and is not transferable. This w ar ranty covers brand new products only, which have not been alter ed, modified nor repaired since shipmen t from factory. Proof o f purchase (dated bill of sale), model name and ser ial [...]