Drolet SIT 0.820.634 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Drolet SIT 0.820.634, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Drolet SIT 0.820.634 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Drolet SIT 0.820.634. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Drolet SIT 0.820.634 should contain:
- informations concerning technical data of Drolet SIT 0.820.634
- name of the manufacturer and a year of construction of the Drolet SIT 0.820.634 item
- rules of operation, control and maintenance of the Drolet SIT 0.820.634 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Drolet SIT 0.820.634 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Drolet SIT 0.820.634, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Drolet service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Drolet SIT 0.820.634.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Drolet SIT 0.820.634 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ULTRA FLAME DIRECT VENT GAS STOVE INSTRUCTIONS MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.[...]

  • Page 2

    ULTRA FLAME DIRECT VENT GAS STOVE 1 TABLE OF CONTENTS GENERAL INFORMATION .................................................................................................................................................... 2 WARNING .....................................................................................................................[...]

  • Page 3

    ULTRA FLAME DIRECT VENT GAS STOVE 2 GENERAL INFORMATION The ULTRA FLAME DIRECT VENT GAS STOVE is a high-efficiency gas appliance with a maximum input rating of 30 000 Btu/h (8,8 kW) with natural gas or 26,000 Btu/h (7,6 kW) with propane. It features an adjustable millivolt valve and a constant pilot independent of any electrical source. Your applia[...]

  • Page 4

    ULTRA FLAME DIRECT VENT GAS STOVE 3 TECHNICAL SPÉCIFICATIONS Dimensions TOP VIEW Dimensions Height : 29 in 735 mm Width : 26 in 920 mm Depth : 23 in 585 mm Ceramic Glass F ront : 18 3/16 in x 15 15/16 in 462 mm x 405 mm Sides : 5 1/16 in x 15 15/16 in 129 mm x 405 mm Weight : 140 lbs 64 kg Color : Metallic Black Clearances to Combustibles • Back[...]

  • Page 5

    ULTRA FLAME DIRECT VENT GAS STOVE 4 Burner Natural Gas Propane LP Maximum Input, BTU/h (kW) minimum : maximum : 20 000 (5,9) 30 000 (8,8) 20 000 (5,9) 26 000 (7,6) Inlet Pressure INWC (kPa) minimum : maximum : 5,0 (1,3) 7,0 (1,8) 11,0 (2,8) 14,0 (3,5) Manifold Pressure INWC (kPa) minimum : maximum : 1,8 (0,5) 3,5 (0,9) 7,0 (1,8) 10,0 (2,5) Burner o[...]

  • Page 6

    ULTRA FLAME DIRECT VENT GAS STOVE 5 Available Wall Venting Kits Venting Kit for Direct Installation AC05506 Venting Kit for Corner Installation AC05507 DESCRIPTION • Outer pipe ( ∅ 8 in.) for admission of fuel-air in carbon steel, black 24GA ; • Inner flexible pipe ( ∅ 5 in.) in aluminum allowing the exhaust of the flue ; • Snorkel type v[...]

  • Page 7

    ULTRA FLAME DIRECT VENT GAS STOVE 6 SELECTING TYPICAL INSTALLATION Safety Notice • Improper installation may result in a house fire. Fo llow installation directions. Installation must be done in accordance w ith local building codes or, in the absence of local codes, w ith current CAN/CGA B 149 installation codes for gas appliances (Canada) and c[...]

  • Page 8

    ULTRA FLAME DIRECT VENT GAS STOVE 7 Critical Length of Venting Pipes The following table shows maximum length to be respected while installing your appliance: In conclusion: • If you have no rise (Vertical run= 0 ft) :  The maximum horizontal run is 5 ft ; • If you have a known horizontal run :  Minimum vertical run = Horizontal run – 5[...]

  • Page 9

    ULTRA FLAME DIRECT VENT GAS STOVE 8 K. 72" Clearance to a mechanical air supply inlet L. 84" Clearance above paved sidewalk or a paved driveway lo cated on public property. A vent shall not terminate directly above a sidew alk or paved driveway w hich is located betw een tw o single family dwellings and serves both dwelling M. 36" Cl[...]

  • Page 10

    ULTRA FLAME DIRECT VENT GAS STOVE 9 Installation of Wall Venting Kits Direct Vent Kit VENT TERMINAL RADIATION SHIELD -min 1" -max 60" Direct Vent Direct Vent Details 1. Move the stove to its position; 2. Install temporary a 8 in. section (4) to visualize where the opening to be done thru the wall. Center of the opening should be at about [...]

  • Page 11

    ULTRA FLAME DIRECT VENT GAS STOVE 10 13. Seal around the 8 in. pipe to prevent cold air to get into the house. 14. Seal around the cover slots to avoid water infiltration into the vent terminal; 15. Insert spring spacers into the 5 in. flexible pipe; 16. Put some high temp silicone on the stove’s 5 in. flange. Insert one locking band on the 5 in.[...]

  • Page 12

    ULTRA FLAME DIRECT VENT GAS STOVE 11 8. Secure the 8 in. pipe to vent terminal wall plate with the metal screw; 9. Fix finally the vent terminal wall plate with six 2 ½ in screws (12). 10. Insert the 5 in. flexible pipe (3) into the 8 in. pipe and fix it to the vent terminal casing. Use high temperature silicone and one locking band to secure it i[...]

  • Page 13

    ULTRA FLAME DIRECT VENT GAS STOVE 12 Direct Vent Kit for Basement Installation 1. Move the stove to its position; 2. Install temporary an 8 in. section (4) to visualize where the opening to be done thru the wall. Center of the opening should be at about 23 ½ “above the base of the stove; Note: Horizontal run should have a slope of ¼ in per foot[...]

  • Page 14

    ULTRA FLAME DIRECT VENT GAS STOVE 13 11. Install the vent casing and the cover in place 12. Seal around the terminal to prevent water leakage into the house 13. Seal around the 8 in. pipe to prevent cold air to get into the house. 14. Seal around the cover slots to avoid water infiltration into the vent terminal; 15. Insert spring spacers into the [...]

  • Page 15

    ULTRA FLAME DIRECT VENT GAS STOVE 14 Direct Vent Kit for Floor Installation 1. Move the stove to its position; 2. Install temporarily an 8 in. section (4) to visualize where the opening is to be done thru the wall. Center of the opening should be at about 23 ½‘’ above the base of the stove; Note: Horizontal run should have a slope of ¼ in per[...]

  • Page 16

    ULTRA FLAME DIRECT VENT GAS STOVE 15 11. Install the vent casing and the cover in place 12. Seal around the terminal to prevent water leakage into the house 13. Seal around the 8 in. pipe to prevent cold air to get into the house. 14. Seal around the cover slots to avoid wa ter infiltration into the vent terminal; 15. Insert spring spacers onto the[...]

  • Page 17

    ULTRA FLAME DIRECT VENT GAS STOVE 16 Gas Piping • Move the ULTRA FLAME to the desired position. • Mark the location for the gas inlet pipe and the location where the vent pipes will go through the wall. Remove the appliance. • Route a 3/8" minimum NPT iron pipe gas line to the desired location. • Install a shutoff valve to the gas line[...]

  • Page 18

    ULTRA FLAME DIRECT VENT GAS STOVE 17 Logs Installation 1. Remove the front glass. 2. Locate the log grate in the retainers in the right and left rear corners. 3. Place the rear log (1) against the rear log stop. Make sure grooves under the log line up with the grate. 4. Place logs 2 and 3 against the stops in the middle of the grate. Again see t ha[...]

  • Page 19

    ULTRA FLAME DIRECT VENT GAS STOVE 18 OPERATION OF YOUR STOVE For your safety CAUTION: • A qualified installer must perform installation of the appliance, ve nting, piping and adjustments. • During operation, this stove is hot. Do not touch. Keep children, clothing and flammable materials aw ay • Hot when in operation. Keep children, furnit ur[...]

  • Page 20

    ULTRA FLAME DIRECT VENT GAS STOVE 19 Shut down Instructions To turn the burner OFF • Push in and rotate the gas control knob clockwise 3 to "PILOT" position. Do not force. To turn the pilot OFF • Push in and rotate the gas control knob clockwise 3 to "OFF" position. Do not force. Optional Blower The blower control contains a[...]

  • Page 21

    ULTRA FLAME DIRECT VENT GAS STOVE 20 MAINTENANCE INSTRUCTIONS TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFOR E SERVICING THE APPLIANCE. Yearly maintenance • The venting system and the gas stove should be inspected at least once a year. • Remove the front glass and the logs and clean them if necessary. • The[...]

  • Page 22

    ULTRA FLAME DIRECT VENT GAS STOVE 21 Burner Removing the Burner • Remove the glass front assembly. Lift out the gr ate and hearth insert around burner. Unscrew the burner from the bottom of the combustion chamber, • Slide the burner out from the ventury to wards left. Get it out from the stove. Burner Installation • Get the burner back in pla[...]

  • Page 23

    ULTRA FLAME DIRECT VENT GAS STOVE 22 Pilot Assembly OPTIONS DESCRIPTION Part # Millivolt Wall Thermostat AC05558 Blower AC05529 Direct Vent Kit AC05506 Direct Vent Kit Corner Installation AC05507 Direct Vent Kit Basement Installation AC05509 Direct Vent Kit Floor Installation AC05502 REMPLACEMENT PARTS DESCRIPTION Part # 5 logs set AC05791 Burner ([...]

  • Page 24

    ULTRA FLAME DIRECT VENT GAS STOVE 23 1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : tech@drolet.ca web site : drolet .ca LIMITED WARRANTY The manufacturers warranty extends only to the original consumer purc haser and is not transferable. This warranty covers brand new products only, w hich hav[...]