Ducane (HVAC) 2HP14 manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ducane (HVAC) 2HP14, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ducane (HVAC) 2HP14 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ducane (HVAC) 2HP14. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ducane (HVAC) 2HP14 should contain:
- informations concerning technical data of Ducane (HVAC) 2HP14
- name of the manufacturer and a year of construction of the Ducane (HVAC) 2HP14 item
- rules of operation, control and maintenance of the Ducane (HVAC) 2HP14 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ducane (HVAC) 2HP14 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ducane (HVAC) 2HP14, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ducane (HVAC) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ducane (HVAC) 2HP14.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ducane (HVAC) 2HP14 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    2HP14 Features • Durable scroll compressors, with internal pressure relief valves and inherent thermal protection • High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity • Top discharge directs hot air and sound away from living area and shrubbery • All units are factory run tested • A[...]

  • Page 2

    2 HP 14 B 36 P - 1 A Model Number Guide Refrigerant – 2 = R22 AC = Condenser HP = Heat Pump 14 - 14 SEER Nominal Family / Coil Protection B = Non-Louvered L = Louvered A = Service Level Revision Code Voltage P - 208-230v/60hz Single Phase Nominal Capacity 36 - 36,000 Btuh Sound Ratings Model Sound Rating (dBa) Weight 2HP14(B,L)18P-1* 78 162 2HP14[...]

  • Page 3

    2HP14 Split System Enhanced Heat Pump seer 14 Outdoor Model Indoor Model Cooling Heating CFM Required Indoor Expansion Device BTUH SEER EER S/T BTUH HSPF 2HP14*18P-1* RBCS2M18COONAT 19,000 14.00 12.5 0.71 17,000 7.70 650 TXV3 RBCS2M18OONAP+TXV 19,000 14.00 12.5 0.71 17,000 7.70 650 TXV3 HP14B18/EC2T28/CMPEV050 19,000 15.00 13.0 0.72 17,000 7.70 650[...]

  • Page 4

    2HP14 Split System Enhanced Heat Pump seer 14 Outdoor Model Indoor Model Cooling Heating CFM Required Indoor Expansion Device BTUH SEER EER S/T BTUH HSPF 2HP14*30P-1* RBC52M30COONAT 28,400 14.00 12.0 0.72 26,000 8.20 1,050 TXV3 RBCS2M30COONAP+TXV 28,400 14.00 12.0 0.72 26,000 8.20 1,050 TXV3 EC2T36 28,400 13.50 12.0 0.72 26,000 7.70 1,050 TXV3 EC1P[...]

  • Page 5

    2HP14 Split System Enhanced Heat Pump seer 14 Outdoor Model Indoor Model Cooling Heating CFM Required Indoor Expansion Device BTUH SEER EER S/T BTUH HSPF 2HP14*36P-1* Cont... EC2T48+MPGAV075 35,000 14.50 12.0 0.73 32,400 8.00 1,250 TXV3 EC1P48+MPGAV075+TXV 35,000 14.50 12.0 0.73 32,400 8.00 1,250 TXV3 EC2T36+MPGAV100 35,000 14.50 12.0 0.74 33,000 8[...]

  • Page 6

    2HP14 Split System Enhanced Heat Pump seer 14 Expanded Cooling Performance Indoor 65° F Outdoor 85° F Outdoor 95° F Outdoor 105° F Outdoor 115° F Outdoor Outdoor Model Indoor Model Temp. (DB /WB° F) Btuh S / T kW Btuh S / T kW Btuh S / T kW Btuh S / T kW Btuh S / T kW Ratio Ratio Ratio Ratio Ratio 2HP14*18P-1* RBCS2M18C*** 80/67 20,700 0.64 1[...]

  • Page 7

    2HP14 Split System Enhanced Heat Pump seer 14 Accessories Description Kit Number Catalog No. Where Used 18 24 30 36 42 48 60 Hard Start Kit 20442715 12W59 x x x x x x x High Pressure Kit 20442506 14W09 x x x x x x x Low Pressure Kit Standard Factory Installed on all models Short Cycle Protection Standard Factory Installed on all models Crankcase He[...]

  • Page 8

    Form No. D2HP14B/L-100 (11/07) ©2007 Allied Air Enterprises Inc. a Lennox International Inc. Company Printed in the U.S.A. D&S www.ducanehvac.com 1-800-448-5872 All specifications and illustrations subject to change without notice and without incurring obligations. Unit Dimensions Model A - Width B - Depth C - Height (Inches) (Inches) (Inches)[...]