Ducane (HVAC) EH1P manual

1
2
3
4
5
6

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ducane (HVAC) EH1P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ducane (HVAC) EH1P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ducane (HVAC) EH1P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ducane (HVAC) EH1P should contain:
- informations concerning technical data of Ducane (HVAC) EH1P
- name of the manufacturer and a year of construction of the Ducane (HVAC) EH1P item
- rules of operation, control and maintenance of the Ducane (HVAC) EH1P item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ducane (HVAC) EH1P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ducane (HVAC) EH1P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ducane (HVAC) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ducane (HVAC) EH1P.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ducane (HVAC) EH1P item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Ducane Evaporator Coils FEA TURES All coils are compatible with R22 or R410A All drain pans are compatible with UV lights EC1P/EM1P Cased Upflow/Counterflow (EC1P) for application flexibility Upflow/Horizontal (EM1P) for application flexibility Microban® antimicrobial additive in the drain pan to resist mold and mildew growth One of the lowest wat[...]

  • Page 2

    Model Number Guide E E E E EU U U U UP 1P 1 P 1 P 1P 18 18 1 8 1 8 18 1A A A A AN N N N N- - - - -1 1 1 1 1 l i o C r o t a r o p a v E = E s e i r e S d e s a c n U = Ur o l o C d e s a C = C e l b a c i l p p A t o N = N n o i t i s o p - i t l u M = M d e s s o b m E d e z i n a v l a G = M l a t n o z i r o H = H e c a n r u F s a G g n i h c t[...]

  • Page 3

    Dimensions - Cased l e d o M A ) . n i ( B ) . n i ( C ) . n i ( D ) . n i ( E ) . n i ( F ) . n i ( G ) . n i ( e c i f i r O t n a r e g i r f e R s n o i t c e n n o C t h g i e W ) . s b l ( d i u q i L ) . n i ( r o p a V ) . n i ( M A N 9 1 P 1 C E2 / 1 3 12 / 1 6 12 12 / 1 2 10 21 22 / 1 1 25 58 / 34 / 35 2 M A N 8 1 P 1 C E2 / 1 3 12 / 1 6 [...]

  • Page 4

    Dimensions - Multi-Position l e d o M A ) . n i ( B ) . n i ( C ) . n i ( D ) . n i ( E ) . n i ( F ) . n i ( G ) . n i ( e c i f i r O n o i t a r e g i r f e R s n o i t c e n n o C t h g i e W ) . s b l ( d i u q i L ) . n i ( r o p a V ) . n i ( 1 - M A N 9 1 P 1 M E2 / 1 3 12 / 1 5 22 12 / 1 2 10 21 22 / 1 1 25 5 0 .8 / 34 / 33 3 1 - M A N 8 1[...]

  • Page 5

    Dimensions - Uncased l e d o M A ) . n i ( B ) . n i ( C ) . n i ( D ) . n i ( E ) . n i ( e c i f i r O s n o i t c e n n o C n o i t a r e g i r f e R t h g i e W ) . s b l ( d i u q i L ) . n i ( r o p a V ) . n i ( 1 - N A N 9 1 P 1 U E3 12 / 1 9 18 / 1 5 12 / 1 92 / 1 45 5 0 .8 / 34 / 37 1 1 - N A N 8 1 P 1 U E3 12 / 1 9 15 12 / 1 92 / 1 45 5 [...]

  • Page 6

    All specifications and illustrations subject to change without notice and without incurring obligations.. www.ducanehvac.com For more information, contact your local Ducane distributor. Form No. DEU/C/M/H1P-100 (6/06) ©Excel Comfort Systems, Inc. 2006 Printed in U.S.A. *DEUCMH1P-100-11-05* Dimensions - Horizontal Width Airflow F ront View Suc. Liq[...]