Go to page of
Similar user manuals
-
Electric Heater
Dyna-Glo RMC-KFA65TDLX, RMC-KFA120TDLX, RMC-KFA170TDLX
12 pages 0.65 mb -
Electric Heater
Dyna-Glo RMC-KFA45T, RMC-KFA65T, RMC-KFA120T, RMC-KFA170T, RMC-KFA210T
28 pages 1.38 mb -
Electric Heater
Dyna-Glo RMC-KFA45T
28 pages 1.38 mb -
Electric Heater
Dyna-Glo Dyna-Glo RMC-KFA45T, RMC-KFA65T, RMC-KFA120T, RMC-KFA170T, RMC-KFA210T
28 pages 1.45 mb -
Electric Heater
Dyna-Glo RMC-TT15
16 pages 2.85 mb -
Electric Heater
Dyna-Glo RMC-KFA65T
28 pages 1.38 mb -
Electric Heater
Dyna-Glo RMC-KFA210T
28 pages 1.38 mb -
Electric Heater
Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX
12 pages 0.65 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dyna-Glo RMC-KFA65T, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dyna-Glo RMC-KFA65T one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dyna-Glo RMC-KFA65T. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dyna-Glo RMC-KFA65T should contain:
- informations concerning technical data of Dyna-Glo RMC-KFA65T
- name of the manufacturer and a year of construction of the Dyna-Glo RMC-KFA65T item
- rules of operation, control and maintenance of the Dyna-Glo RMC-KFA65T item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dyna-Glo RMC-KFA65T alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dyna-Glo RMC-KFA65T, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dyna-Glo service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dyna-Glo RMC-KFA65T.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dyna-Glo RMC-KFA65T item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CFM RMC INTERNA TIONAL 3501 W . HOW ARD ST ., SKOKIE, IL 60076 1-800-527-4948 POR T ABLE FORCED AIR HEA TERS “USER’S MANUAL” Before the first use of this heater , please read this USER’S MANUAL very carefully . This USER’S MANUAL has been designed to instruct you as to the proper manner in which to assemble, maintain, store, and most impo[...]
-
Page 2
1 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! DANGER - IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR CARBON MONOXIDE POISONING. W ARNINGS: 1. RISK OF INDOOR AIR POLLUTION! • Use this heater only in well ventilated areas. Provide at least a three-square foot (2,800 sq[...]
-
Page 3
2 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! ITEM P AGE # PRECAUTIONS - SAFETY GUIDE 1 1. INTRODUCTION 2 2. FEA TURES 2 3. UNP ACKING AND ASSEMBL Y 4 4. KEROSENE (1-K OR NO. 1 FUEL OIL) 6 5. OVER VIEW OF HEA TER DESIGN 7 6. FUELING YOUR HEA TER 8 7. OPERA TION 8 8. LONG TERM STORAGE OF YOUR HEA TER 9 9. MAINTENANCE 9 10. TROUBLE SHOOTING G[...]
-
Page 4
3 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! Figure 2. RMC-KFA120T / RMC-KFA170T MODELS Figure 2. RMC-KFA210T MODEL Hot Air Outlet Handle Upper Shell Lower Shell Fuel Gauge Side Cover Power/Reset Switch Upper Shell Fan Guard Power Cord Fuel T ank Fuel Cap Thermostat Knob Lamp Hot Air Outlet Handle Upper Shell Lower Shell Fuel Gauge Side Co[...]
-
Page 5
4 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! Figure 5. RMC-KFA120T / RMC-KFA170T / RMC-KFA210T MODELS Handle Screws Wheels Split pin And Flat W asher Screws And Nuts Handle Wheel Support Frame Axle 3. UNP ACKING AND ASSEMBL Y 1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX. (Fig. 4 and 5) NOTE: Save the shipping carton and pack[...]
-
Page 6
5 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 2. ASSEMBLY A. For RMC-KFA45T/RMC-KFA65T Models only (Figure 6) Tools Required • Medium Phillips Screwdriver 1. Align the holes on the upper shell with the 2 mounting holes on the handle as shown in Figure 6. 2. Secure each hole with a screw. B. For RMC-KFA120T / RMC-KFA170T / RMC-KFA210T Mode[...]
-
Page 7
6 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! Screw Air Inlet Axle Split pin Flat W asher Wheel Nut Wheel Support Frame Fuel T ank Flange Hot Air Outlet Handle Extended Hub 4. KEROSENE (1-K) It is EXTREMELY IMPORTANT for the proper operation of this heater that you use the correct grade of kerosene. The correct grade of kerosene is identifi[...]
-
Page 8
7 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 5. OVER VIEW OF HEA TERS DESIGN Fuel System: This heater is equipped with an electric air pump that forces air through the air line connected to the fuel intake and then through a nozzle in the burner head. When the air passes in front of the fuel intake it causes fuel to rise from the tank and [...]
-
Page 9
8 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 6. FUELING YOUR HEA TER NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE: FILL THE TANK OUTDOORS. DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED. IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER: The first time you light the heater, it should be done outdoors . This allows the o[...]
-
Page 10
9 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! Figure 10 TO STOP HEATER 1. Turn switch to “OFF” and unplug power cord. TO RESTART HEATER 1.Wait 10 seconds after stopping heater. 2. Repeat steps under to start heater . 8. LONG TERM ST ORAGE OF YOUR HEA TER 1. Drain fuel tank through fuel cap opening. 2. Using a small amount of kerosene, s[...]
-
Page 11
C.) AIR OUTPUT FIL TER, LINT FIL TER REPLACE EVERY 500 HOURS OF OPERATION OR ONCE A YEAR. - Remove upper shell and fan guard (See page 9). - Remove end filter cover screws using medium phillips screwdriver. - Remove end filter cover. - Replace air output and lint filter. - Reinstall end filter cover. - Reinstall fan guard and upper shell. D.) F AN [...]
-
Page 12
11 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! Figure 15. Figure 14. F .) SP ARK PLUG CLEAN AND REGAP EVERY 600 HOURS OPERATION OR REPLACE AS NEEDED. (For RMC-KFA 45T/65T/120T/170T Models Only) - Remove upper shell (See page 9). - Remove fan (See page 10). - Remove ignitor wire from spark plug. - Remove spark plug from burner head using med[...]
-
Page 13
12 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! (For RMC-KFA 210T Models Only) - Remove upper shell (See page 9). - Remove fan (See page 10). - Remove ignitor wire from spark plug. - Remove spark plug from bracket-spark using medium phillips screwdriver. - Clean and regap spark plug electrodes to 3.5mm gap.(0.138 " ) - ReInstall spark p[...]
-
Page 14
13 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! H .) FUEL FIL TER CLEAN OR REPLACE TWICE A HEATING SEASON OR AS NEEDED. (For RMC-KFA 45T/65T/120T/170T Models Only) - Remove side cover screws using medium phillips screwdriver. - Remove side cover. - Pull fuel line off fuel filter neck. - Turn fuel filter 90 。 to counter clockwise and pull t[...]
-
Page 15
14 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! I) FUEL VALVE ( For RMC-KFA210T Model only) - Remove side cover screws using medium phillips screwdriver (See page 13). - Remove upper shell (See page 9). - Remove fan (See page 10). - Pull fuel line (lower and upper) off the fuel valve fittings (See figure 21). - Disconnet red and orange wires[...]
-
Page 16
15 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! I .) PUMP PRESSURE ADJUSTMENT - Remove pressure gauge plug from end filter cover. - Install accessory pressure gauge. - Start heater (See Operation, page 8) Allow motor to reach full speed - Adjust pressure (Using a flat blade screwdriver) Turn relief valve to right to increase pressure. Turn r[...]
-
Page 17
16 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 10 . TROUBLE SHOOTING GUIDE Heater ignites but MAIN PCB 1. Wrong pump pressure 1. See Pump Pressure Adjustment, assembly shuts heater off after page 15. a short period of time. 2. Dirty Air Output, Air Intake 2. See Air Output, Air intake (Lamp is flickering) and Lint Filter and Lint Filters, p[...]
-
Page 18
17 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 11 . WIRING DIAGRAM A) WIRING DIAGRAM (RMC-KFA45T / RMC-KFA65T) B) WIRING DIAGRAM (RMC-KFA120T)[...]
-
Page 19
18 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 11 . WIRING DIAGRAM C) WIRING DIAGRAM (RMC-KFA170T) D) WIRING DIAGRAM (RMC-KFA210T)[...]
-
Page 20
19 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 12 . SPECIFICA TIONS RMC-KFA45T / RMC-KFA65T RMC-KFA120T / RMC-KFA170T / RMC-KFA210T 24.75" 39" 20.5" KF A120T KF A170T KF A210T 23" 19" 33.5" H D W MODEL RMC-KFA45T RMC-KFA65T RMC-KFA120T RMC-KFA170T RMC-KFA210T BTU/Hr . 45,000 65,000 120,000 170,000 210,000 Fuel [...]
-
Page 21
NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 13 . EXPLODED P AR TS DRA WING (RMC-KF A45T/65T/120T/170T Models Only) NOTE: SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. 32 33 16 15 25 23 24 30 22 18 28 31 3 20 15 19 21 14 26 23-1 11 12 13 2 4 1 6 27 5 29 8 9 10 7 17-7 17-8 17-5 17-6 17-3 17-9 17-10 17-4 17-2 17-1 22-11 22-15 22-18[...]
-
Page 22
21 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 13 . EXPLODED P AR TS DRA WING (RMC-KF A 210T Model Only) 34 35 Fuel Valve Assembly 17 31 32 27 28 24 27-1 25 21 18 26 21 23 14-4 14-2 14-5 14-1 14-3 19 13 12 22 29 33 3 16 20 15 11 2 4 1 6 5 30 14 8 9 10 7 18-3 18-1 18-12 18-7 18-13 18-6 18-5 18-8 18-4 18-9 18-10 18-11 23-11 23-19 23-18 23-13 [...]
-
Page 23
22 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 14 . P AR TS LIST (RMC-KF A 45T/65T/120T/170T Models Only) KEY NO. DESCRIPTION PART NO. RMC-KFA45T RMC-KFA65T RMC-KFA120T RMC-KFA170T 1 Fuel Tank Assembly 2151-0005-00 2151-0005-00 2151-0002-00 2151-0001-00 2 Fuel Gauge 2156-0005-00 2156-0005-00 2156-0001-00 2156-0001-00 3 Fuel Filter Assembly [...]
-
Page 24
KEY NO. DESCRIPTION PART NO. RMC-KFA45T RMC-KFA65T RMC-KFA120T RMC-KFA170T 22-6 Rotor Kit FA1000 FA1000 FA1000 FA1000 22-7 Blade See 22-6 See 22-6 See 22-6 See 22-6 22-8 End Pump Cover 3531-0008-00 3531-0008-00 3531-0008-00 3531-0008-00 22-9 Nipple 3541-0039-00 3541-0039-00 3541-0020-00 3541-0020-00 22-10 Flange Bolt 4329-0014-00 4329-0014-00 4329-[...]
-
Page 25
24 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 14 . P AR TS LIST (RMC-KF A 210T Model Only) KEY No. P AR T No. RMC-KF A210T DESCRIPTION 2151-0001-00 2156-0001-00 2155-0001-00 2151-0003-00 3980-0031-00 3712-0011-00 39A0-0044-00 215A-0005-00 3713-0045-00 3231-0072-00 3111-0123-00 3712-0004-00 3712-0035-00 2154-0015-00 39A0-0055-00 3541-0020-0[...]
-
Page 26
25 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! ACCESSORIES Air Pressure Gauge F A1010 (all models) Thermostat F A1012 (all models) FOR TECHNICAL ASSIST ANCE SEE YOUR LOCAL RET AILER OR CONT ACT US A T : Phone: 1-800-527-4948 KEY No. P AR T No. RMC-KF A210T DESCRIPTION 3970-0060-00 3121-0258-00 3121-0257-00 3541-0050-00 4321-0180-00 See 23-7[...]
-
Page 27
1 2 1 2 3 5 9 6 7 8 4 NEVER LEA VE THE HEA TER UNA TTENDED WHILE BURNING! 14 . P AR TS LIST (WHEELS AND HANDLE) 1) RMC-KF A45T/65T MODELS 2) RMC-KF A120T/170T/210T MODEL KEY NO. DESCRIPTION PART NO. RMC-KFA45T RMC-KFA65T QTY 1 Handle 3231-0073-00 3231-0073-00 1 2 Screw 4319-0015-00 4319-0015-00 2 KEY NO. DESCRIPTION PART NO. MC-KFA120T MC-KFA170T M[...]
-
Page 28
4221 - 0059- 00 07/03 Rev. 00 EDITION 2003[...]