Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dynacord DPA 4120, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dynacord DPA 4120 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dynacord DPA 4120. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dynacord DPA 4120 should contain:
- informations concerning technical data of Dynacord DPA 4120
- name of the manufacturer and a year of construction of the Dynacord DPA 4120 item
- rules of operation, control and maintenance of the Dynacord DPA 4120 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dynacord DPA 4120 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dynacord DPA 4120, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dynacord service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dynacord DPA 4120.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dynacord DPA 4120 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
23 POWER AMPLIFIER DPA 4120 / DPA 4140 OWNER'S MANUAL 40 0 W A TT S P O W E R A M P L I F I E R P R O T E C T S T A ND B Y T E S T D P A 4 140 G R O UND F A U L T C L I P 0d B - 13d B R EA D Y Performance Features Power amplifier with 200 W or 400 W output power according to the IEC 283-3 standard within a 19“ - cabinet (3 HU) providing the [...]
-
Page 2
24[...]
-
Page 3
25 Indicators, controls and connections 400 W A TT S P O W E R A M P L I F I E R G R O UN D F A U L T C L I P 0d B - 13d B R EA D Y P R O T E C T S T A N D BY T ES T D PA 414 0 8 6 7 1 2 3 4 5 P O W E R + 1 1 5 V / 2 30 V A C 5 0 - 60 H z T 8 A F O R 1 15 V T 4 A F O R 2 30 V G R O U ND E D U N G R O UND E D CH AS S I S S W I T CH C I RC U I T T O [...]
-
Page 4
26 19 CIRCUIT ⊥ TO CHASSIS SWITCH 20 DC INPUT 24V = (battery) 21 IDENT ADDRESS switch 22 REMOTE CONTROL connectors 23 STATUS indicator A locking screws power supply printed board B locking screws INPUT MODULE Contents Performance Features .............................................................................................................[...]
-
Page 5
27 14.3 NRS 90222 remote module ......................................................................................................... 69 14.4 NRS 90224 pilot tone and ground fault surveillance ........................................................................ 70 15. Warranty ................................................................[...]
-
Page 6
28 DPA 4120 : For 115V AC operation, the mains fuse (11) has to be replaced by a slow blowing 4 ampere type , labeled " T4A " (see also paragraph 11.1). DPA 4140 : For 115V AC operation, the mains fuse (11) has to be replaced by a slow blowing 8 ampere type , labeled " T8A " (see also paragraph 11.2). If the appliance is correct[...]
-
Page 7
29 figure 1 connections of the input sockets figure 2 LF cable for coupling two amplifiers DPA 41xx 5. Outputs 5.1 POWER OUTPUT The power output is balanced and off-ground potential. The output is factory-configured for the connection of 100V loudspeaker systems. Connection has to be performed by inserting the supplied 5-pole plug into the power ou[...]
-
Page 8
30 of 200W (connection impedance 50 ohms) with the DPA 4120, respectively 400W (connection impedance 25 ohms) with the DPA 4140. Connection is performed using the 100V output (17) (see also figure 3). In a few special cases it is also possible to operate the loudspeaker systems with 70V or 50V output voltage (see also paragraph 7). Caution It is po[...]
-
Page 9
31 6.1 STANDBY indicator When the appliance is correctly connected and mains and/or battery power is present, the green STANDBY indicator (4) will light. 6.2 READY indicator Both amplifiers, the DPA 4120 and the DPA 4140, employ power-on switching delays of approximately 3 sec. to effectively eliminate power-on switching noise. After this time, the[...]
-
Page 10
32 output bridge B411 to 100 V B407 70 V B408 50 V B409 4 ohms B410 table 1 bridge B411 settings figure 5 coding-bridges S405 / S406 settings switching the output voltage output recognitio n OUTPUT CONFIG Caution It is possible that during operation shock-hazard output voltages can be present at the POWER OUTPUT connector (>34V peak value). Thus[...]
-
Page 11
33 Note: Functioning changes in the models DPA 4120 (starting with serial numbers: 100 11) and DPA 4140 (starting with serial numbers: 100 11) in association with the input module NRS 90225: To achieve reliable attenuation of switching noise (knacks), the monitor output stays muted as long as the READY -relay is not pulled. Because of circuit desig[...]
-
Page 12
34 - re-insert the input module and tighten the locking screws (B). 8.4 NRS 90227 output transformer for the floating, balanced monitor output In case that floating monitor outputs are required, the outputs of the INPUT MODULE NRS 90225 and REMOTE MODULE NRS 90222 are prepared for retrofitting output transformers. If so, it is necessary to addition[...]
-
Page 13
35 Output Transformer NRS 90227 figure 6 printed board assemb ly 81338 showing the input transformer NRS 90208 and the output transformer NRS 90 227 Input Transformer NRS 90208 Output Transformer 90 227 figure 7 printed board assembly 81339 showing the input transformer NRS 90208 and the output transformer NRS 90 227 8.5 NRS 90224 pilot tone & [...]
-
Page 14
36 When off-ground potential loudspeaker cable networks are employed we recommend insulation-monitoring using the ground fault surveillance module NRS 90224. Error recognition: An occurring ground fault either signals that one of the cables is damaged - which most likely point towards a total line interruption in the near future - or that connectio[...]
-
Page 15
37 figure 8 printed board assembly 84187 in the DPA 4120 showing the NRS 90224 pilot tone & ground fault surveillance and the bridges B411 and S405, S406 for switching the output voltage; inserted B 411[...]
-
Page 16
38 NRS 90 224 figure 9 printed board assembly 84175 in the DPA 4140 showing the NRS 90224 pilot tone & ground fault surveillance and the bridges B411 and S405, S406 for switching the output voltage; inserted Checking the pilot tone surveillance function: When the NRS 90224 is installed and the power amplifier is switched on, the green READY ind[...]
-
Page 17
39 Checking the ground fault surveillance function: When the NRS 90224 is installed and the power amplifier is switched on, the green READY indicator (7) has to light. Utilizing an external switch to connect one pole of the 100V-loudspeaker network via a 47 k ohms resistor for approximately 5 seconds to ground potential, the corresponding red GROUN[...]
-
Page 18
40 F 503 F 502 figure 10 printed board assembly 85270 in the DPA 4120 showing the DC fuses F502 and F503[...]
-
Page 19
41 F 503 F 502 figure 11 printed board assembly 85268 in the DPA 4140 showing the DC fuses F502 and F503[...]
-
Page 20
42 F 601 F 602 figure 12 printed board assemblies 86243 DPA 4120 and DPA 4140 showing the AC fuses F601 and F602 Caution Before opening the appliance, make sure to disconnect the mains and/or battery power source! Replacing the fuses F502 and F503 (only to be carried out by the experienced service technician!) The battery fuses F502 and F503 are lo[...]
-
Page 21
43 Caution For security reasons it is necessary to ensure that, after the installation is completed, all wiring located beneath the power supply input PCB are within a distance of at least 6 mm to the printed board assembly. 12. Specifications 12.1 DPA 4120 power amplifier 200 W power supply: mains operation 115 V / 230 V~ AC, ±10 % mains frequenc[...]
-
Page 22
44 ambient temperature range +5 °C .. +40 °C dimensions (W x H x D) 483 x 132 x 345 mm depth with / without connections max. 400 mm / max. 340 mm weight without extensions 13.2 kg finish anthracite 12.2 DPA 4140 power amplifier 400 W power supply: mains operation 115 V / 230 V~ AC, ± 10 % mains frequency 50 - 60 Hz security class I mains operati[...]
-
Page 23
45 interfering voltage (A) ≤ 1.2 mV = -56 dBu features of the monitor output: electronically balanced nominal output voltage 2 V = + 8.2 dBu nominal load impedance 600 ohms ambient temperature range +5 °C .. +40 °C dimensions (W x H x D) 483 x 132 x 345 mm depth with / without connections max. 400 mm / 340 mm weight without extensions 16.7 kg f[...]