Eagle Electronics Accura 240 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Eagle Electronics Accura 240, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Eagle Electronics Accura 240 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Eagle Electronics Accura 240. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Eagle Electronics Accura 240 should contain:
- informations concerning technical data of Eagle Electronics Accura 240
- name of the manufacturer and a year of construction of the Eagle Electronics Accura 240 item
- rules of operation, control and maintenance of the Eagle Electronics Accura 240 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Eagle Electronics Accura 240 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Eagle Electronics Accura 240, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Eagle Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Eagle Electronics Accura 240.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Eagle Electronics Accura 240 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST INST INST INST INST ALLA ALLA ALLA ALLA ALLA TION AND OPERA TION AND OPERA TION AND OPERA TION AND OPERA TION AND OPERA TION TION TION TION TION INSTR INSTR INSTR INSTR INSTR UCTIONS UCTIONS UCTIONS UCTIONS UCTIONS Accura 240 Accura 240 Accura 240 Accura 240 Accura 240 ™[...]

  • Page 2

    TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS INTRODUCTION ................................................................................................................... ........... 1 INSTALLATION - BRACKET ..............................................................................................[...]

  • Page 3

    1 INTRODUCTION The Accura 240 is the latest member of the Eagle family that combines a high performance sonar with a wide, high definition screen. Using menu features and “soft-key” operation, the Accura 240 is also easy to use. The wide screen shows the underwater world with high resolution and detail. The display and keyboard are also lighted[...]

  • Page 4

    2 POWER CONNECTIONS The Accura 240 works from a twelve-volt battery system. For the best results, attach the power cable directly to the battery. You can attach the power cable to an accessory or power buss, however you may have problems with electrical interference. Therefore, it’s safer to go ahead and attach the power cable directly to the bat[...]

  • Page 5

    3 RED WIRE 3 amp FUSE BLACK WIRE 12 VOLT BATTERY TO SPEED/TEMP OR TEMP SENSORS (Not included) POWER CONNECTIONS To Accura 240 SPEED/TEMPERATURE SENSORS The Accura 240 accepts up to three temperature sensors which can monitor surface water, live well, air, and virtually any other temperature. You do need to be careful when purchasing the temperature[...]

  • Page 6

    4 Sensor Chart (Note: Do not use these sensors in any other combination.) ST-TBK = 1 speed sensor and 1 temperature display ST-T BK + TS-2BK = 2 temp sensors and one speed sensor ST-TBK + TS-2BK + TS-3BK = 3 temp sensors and one speed sensor TS-1BK = 1 temperature sensor TS-12BK = 2 temperature sensors or TS-1BK + TS-2BK = 2 temperature sensors TS-[...]

  • Page 7

    5 Three Temperature Sensors (Water, T-2, and T-3) Three Temperature Sensors plus Speed (Water, T-2, T-3, and Speed) TS-12 BK TS-3 BK ST-TBK TS-2 BK TS-3 BK Accura 240 POWER CABLE Accura 240 POWER CABLE[...]

  • Page 8

    6 KEYBOARD The keyboard has keys arranged in two vertical columns beneath the arrow keys. The menu key near the bottom left corner of the keyboard activates the first menu page. The other keys are used to activate the alarm menu, make menu selections, and change modes. MODE - Pressing this key switches the unit between different sonar modes. MENU -[...]

  • Page 9

    7 MENUS The Accura 240 uses menus extensively to guide you through the functions and features of the unit. To use the menus, simply press the MENU key. The options on the menus let you to customize the unit to your particular needs and water conditions. Use the up and down arrow keys to move to different menus. The left and right arrow keys select [...]

  • Page 10

    8 Full Chart This is the default mode used when the Accura 240 is first turned on. The bottom signal scrolls across the screen from right to left. Depth scales on the right side of the screen makes it easy to determine the depth of fish, struc- ture, and other objects. The line at the top of the screen represents the sur- face. The bottom depth sho[...]

  • Page 11

    9 Window Groups You can change the displays on the Accura 240 by using the windows fea- ture. This lets you use different displays for your own fishing or boating situa- tions. This feature gives you 8 different display screens in the window groups alone. The screens available in the windows mode are divided into two or more windows per screen. Eac[...]

  • Page 12

    10 AUTOMATIC When the Accura 240 is first turned on, the Automatic feature is enabled. This is indicated by the word “AUTO” at the top of the screen. The Automatic fea- ture adjusts the sensitivity and range so the bottom signal is displayed in the lower half of the screen at all times. To turn Automatic off, first press the MENU key, then pres[...]

  • Page 13

    11 The sensitivity menu has left and right arrows, plus a horizontal bar graph. The graph gives a visual indication of the sensitivity level. The number to the right of the bar graph shows the percentage of sensitivity in use. To increase the sensitivity level, press the right arrow key. As you press the key, the menu’s bar graph will grow wider [...]

  • Page 14

    12 range menu appears as shown at right. Press the left or right arrow keys to decrease or increase the range. The available ranges are 0-5, 10, 20, 30, 40, 60, 100, 150, 200, 300, 500, 800, and 1000 feet. After the desired range is displayed, press the EXIT key to erase the range menu. NOTE: The depth capability of the Accura 240 depends on the tr[...]

  • Page 15

    13 ZOOM - MANUAL MODE The Z-IN (zoom-in) and Z-OUT (zoom-out) keys enlarge and reduce the size of the echoes on the screen when the unit is in the manual mode, the same as the automatic mode. However, you can manually adjust the zoom when the unit is in the manual mode. To do this, press the MENU key, then press the right or left arrow keys until t[...]

  • Page 16

    14 down arrow keys until the GRAYLINE menu appears. A screen similar to the one at right appears. Press the left arrow key to decrease the gray level or the right arrow key to increase it. The percentage of GRAYLINE in use changes as the arrow keys are pressed. The bar chart also gives a graphical indication of the GRAYLINE level. You can see the c[...]

  • Page 17

    15 FISH ID The Fish ID feature identifies targets that meet certain conditions as fish. The microcomputer analyses all echoes and eliminates surface clutter, thermoclines, and other signals that are undesirable. In most instances, remaining targets are fish. The Fish ID feature displays symbols on the screen in place of the actual fish echoes. Ther[...]

  • Page 18

    16 When the Accura 240 is turned on, FishTrack is enabled. To turn the FishTrack feature off, press the menu key, then press the up or down arrow keys until the FISH ID menu appears. Now press the left arrow key. Pressing it once switches the FishTrack feature off, but leaves Fish ID on. To turn FishTrack on, press the right arrow key, which highli[...]

  • Page 19

    17 DISPLAY ZOOM BAR When the unit is in the split-screen zoom mode, the zoom bar doesn’t normally show on the screen. The zoom bar shows the section of water on the right side of the screen that is being enlarged on the left side. To turn the zoom bar on continu- ously when the split-screen mode is on, highlight the "Show Zoom Bar" on t[...]

  • Page 20

    18 ALARMS The Accura 240 has three different types of sonar alarms. The first is the Fish Alarm. It sounds when the Fish I.D. feature determines an echo or group of echoes is a fish. Another alarm is the Zone Alarm which consists of a bar. Any echo that appears inside this bar triggers this alarm. The last alarm is called the Depth Alarm. Only the [...]

  • Page 21

    19 the right arrow key again and press the down arrow key once. This changes the "1" at the end of the number to a "0". The depth now shows 10 feet. Press the ENT key to accept this set- ting. The Accura 240 returns to the alarms menu, showing a shallow depth of 10 feet. Now you can activate the alarm by highlighting the "S[...]

  • Page 22

    20 alarm on, press the ALARM key, then highlight the "Fish Alarm" label and press the right arrow key. The unit will revert to the sonar display with the fish alarm turned on. Repeat the above steps to turn the fish alarm off. Note: If the unit is in the manual mode, turning the Fish Alarm on will also turn the automatic mode and Fish ID [...]

  • Page 23

    21 The ASP feature has two levels - Nor- mal and High. If you have high noise levels, try using the “High” ASP set- ting. However, if you are having trouble with noise, we suggest that you take steps to find the interference source and fix it, rather than continually using the unit with the high ASP setting. However, there are times when you ma[...]

  • Page 24

    22 "Speaker" label, then press the left arrow key to turn it off. System Information This screen shows some basic data about the Accura 240. To view this, highlight the "System Info" label on the System Setup menu, then press the right arrow key. The system info screen appears. To erase this screen, press the EXIT key. The Accur[...]

  • Page 25

    23 Simulator The Accura 240 has a simulator built in that lets you use it as if you are on the water. All features and functions of the unit are usable. A message appears occasionally to remind you that the simulator is on. To use the simulator, press the MENU key, then press the up or down arrow keys until the "System Setup" menu appears[...]

  • Page 26

    24 so that the Accura 240 will add one foot to the depth, since the transducer is one foot below the surface. Press the right arrow key, then the up or down arrow keys until 1.0 appears in the "Adj Keel" box, as shown at right, then press the ENT key. This immedi- ately changes the digital depth display at the top of the screen by one foo[...]

  • Page 27

    25 WINDOWS SUMMARY GROUP "F" GROUP "H" GROUP "D" GROUP "A" GROUP "E" GROUP "G" GROUP "C" GROUP "B"[...]

  • Page 28

    26 TROUBLESHOOTING If your unit is not working, or if you need technical help, please use the following troubleshooting section before contacting the factory customer service department. It may save you the trouble of returning your unit. Unit won’t turn on: 1. Check the power cable’s connection at the unit. Also check the wiring. 2. Make certa[...]

  • Page 29

    27 3. The water may be deeper than the sonar’s ability to find the bottom. If the sonar can’t find the bottom signal while it’s in the automatic mode, the digital will flash continuously. It may change the range to limits far greater than the water you are in. If this happens, place the unit in the manual mode, then change the range to a real[...]

  • Page 30

    28 NOISE A major cause of sonar problems is electrical noise. This usually appears on the sonar’s display as random patterns of dots or lines. In severe cases, it can completely cover the screen with black dots, or cause the unit operate erratically, or not at all. To eliminate or minimize the effects of electrical noise, first try to determine t[...]

  • Page 31

    29 EAGLE ELECTRONICS FULL ONE-YEAR WARRANTY “We", “our”, or “us” refers to EAGLE ELECTRONICS, a division of LEI, the manufacturer of this product. “You” or “your” refers to the first person who purchases this product as a consumer item for personal, family, or household use. We warrant this product against defects or malfunct[...]

  • Page 32

    30 Notes:[...]

  • Page 33

    31 How to Obtain Service (Canadian Customers Only) We back your investment in quality products with quick, expert service and genuine Eagle replacement parts. If you need service or repairs, contact the Eagle Factory Customer Service Department at the toll-free number listed below. A technician may be able to solve the problem and save you the inco[...]

  • Page 34

    32 LITHO IN U.S.A. 988-0135-36 How to Obtain Ser vice (U.S.A. Only) We back your investment in quality products with quick, expert service and genuine Eagle ® replacement parts. If you're in the United States and you have questions, please contact the Factory Customer Service Department using our toll-free number listed below. You must send t[...]