Go to page of
Similar user manuals
-
Uninterruptible power supply (
Eaton Powerware 9155-8-N-28-64x7Ah
54 pages -
Uninterruptible power supply (
Eaton 9130i2000T-XL
118 pages -
Uninterruptible power supply (
Eaton Powerware 9355-10-N-25-64x9Ah-MBS
49 pages -
Uninterruptible power supply (
Eaton EX 2200VA 2U
172 pages -
Uninterruptible power supply (
Eaton 9130i3000T-XL
116 pages -
Uninterruptible power supply (
Eaton EX 3000 RT2U Netpack
172 pages -
Uninterruptible power supply (
Eaton Ellipse MAX 850 USBS FR
40 pages -
Uninterruptible power supply (
Eaton EX 1500 RT2U
200 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Eaton 5P 1150VA AU, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Eaton 5P 1150VA AU one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Eaton 5P 1150VA AU. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Eaton 5P 1150VA AU should contain:
- informations concerning technical data of Eaton 5P 1150VA AU
- name of the manufacturer and a year of construction of the Eaton 5P 1150VA AU item
- rules of operation, control and maintenance of the Eaton 5P 1150VA AU item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Eaton 5P 1150VA AU alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Eaton 5P 1150VA AU, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Eaton service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Eaton 5P 1150VA AU.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Eaton 5P 1150VA AU item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
5P 650 AU 5P 650i R 5P 850 AU 5P 850i R 5P 1150 AU 5P 1150i R 5P 1550 AU 5P 1550i R User's guide[...]
-
Page 2
[...]
-
Page 3
ENGLISH Copyright © 2012 EATON All rights reserved. Service and support: Call your local service representative 620-00082-01-au (en) Tower models 5P 650 AU 5P 850 AU 5P 1150 AU 5P 1550 AU 1U Rack models 5P 650i R 5P 850i R 5P 1150i R 5P 1550i R Installation and user manual[...]
-
Page 4
Page 2 620-00082-0 1-au (en) Cer tication Standards Special S ymbols The following are examples of symbols used on the UPS or accessories to aler t you to impor tant information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol. Important instructions that must always be followed. Do not discard the [...]
-
Page 5
Page 3 620-00082-0 1-au (en) ENGLISH Contents 1 . Intr oduction ....................................................................................... 4 1 .1 Environmental protection ................................................................................................... 4 2. Pr esentation ...............................................[...]
-
Page 6
Page 4 620-00082-0 1-au (en) 1. Introduction Thank you for selecting an EA TON product to protect your electrical equipment. The 5P range has been designed with the utmost care. W e recommend that you tak e the time to read this manual to take full advantage of the many features of your UPS (Uninterruptible P ower System). Before installing 5P , pl[...]
-
Page 7
Page 5 620-00082-0 1-au (en) ENGLISH 2. Presentation 2.1 Standar d installations T ower models D H W Description Weights (lb/ kg ) Dimensions (inch/ mm ) D x W x H 5P 650AU 16.60 / 7.52 13.6 x 9.2 x 5.9 / 345 x 233 x 150 5P 850AU 21.90 / 9.93 13.6 x 9.2 x 5.9 / 345 x 233 x 150 5P 1150AU 24.10 / 10.91 13.6 x 9.2 x 5.9 / 345 x 233 x 150 5P 1550AU 35.[...]
-
Page 8
Page 6 620-00082-0 1-au (en) 2. Presentation 2.2 T o wer r ear panels 5P 650 A U / 5P 850 AU / 5P 1 150 A U 3 2 1 4 6a 6b 5 7 8 5P 1550 AU 3 2 1 4 6a 6b 5 7 8 (1) USB communication port (2) RS232 communication port (3) Slot for optional communication card (4) Connector for ROO (remote ON/OFF) or RPO (Remote Power Off) control (5) Outlets for connec[...]
-
Page 9
Page 7 620-00082-0 1-au (en) ENGLISH 2. Presentation 2.3 Rack r ear panels 5P 650i R / 5P 850i R 2 1 4 8 7 3 6a 6b 5 5P 1 150i R 6a 2 1 4 8 7 3 6b 5 5P 1550i R 6a 2 1 4 8 7 3 6b 5 (1) USB communication port (2) RS232 communication port (3) Slot for optional communication card (4) Connector for ROO (remote ON/OFF) or RPO (Remote Power Off) control ([...]
-
Page 10
Page 8 620-00082-0 1-au (en) 2. Presentation 2.4 Contr ol panel TheUPShasave-buttongraphicalLCD.ItprovidesusefulinformationabouttheUPSitself ,loadstatus, events, measurements and settings. T ower models Power On Indicator (green) On battery Indicator (yel - low) Alarm Indicator (red) Normal mode[...]
-
Page 11
Page 9 620-00082-0 1-au (en) ENGLISH 2. Presentation 2.5 LCD descr iption Operation status Load/equipment status Normal mode 100 % 10min 100% 720W 800V A Efficiency: ~98% Battery status Efficiency and load group information As default, or after 5 minutes of inactivity, the LCD displays the screen saver . The backlight LCD automatically dims after [...]
-
Page 12
Page 10 620-00082-0 1-au (en) 2.6 Displa y functions Press the Enter ( ) button to activate the menu options. Use the two middle buttons ( and ) to scroll through the menu structure. Press the Enter ( ) button to select an option. Press the button to cancel or return to the previous menu. Menu map for Displa y Functions. Main menu Submenu Display i[...]
-
Page 13
Page 11 620-00082-0 1-au (en) ENGLISH 2. Presentation Description Available settings Default settings In/Out settings Load segments - Auto shutdown delay [Disable] [0s] [1 s] [2 s]…[65354 s] During a power outage, authorises to keep some equipment running while turning off other equipment. This feature allows to save battery power. Group 1: Disab[...]
-
Page 14
Page 12 620-00082-0 1-au (en) 3. Installation 3.1 Unpacking and cont ents check Tower models 1 2 3 5 6 Rack models 2 3 5 6 4 7 1 8 (1) 5P UPS (2) Quick start and safety instructions (3) User manual and IPSS (Intelligent Power Software Suite) CDROM (4) 2 connection cables for the protected equipment (5) RS232 communication cable (6) USB communicatio[...]
-
Page 15
Page 13 620-00082-0 1-au (en) ENGLISH 3. Installation 3.2 Installation of t ow er models 3.3 Wall installation of rack models 1 1 2 2[...]
-
Page 16
Page 14 620-00082-0 1-au (en) 3.5 Installation of r ack models (850i R / 1 150i R / 1550i R) Follow steps 1 to 4 for module mounting on the rails. 3. Installation The rails and necessary hardw are are supplied by EA TON. 1 1 2 2 3 3 4 4 3.4 Installation of r ack models (650i R only) Follow steps 1 to 3 for rack mounting. 2 3 2 3 1[...]
-
Page 17
Page 15 620-00082-0 1-au (en) ENGLISH 3. Installation 3.5 Communication por ts Connection of RS232 or USB communication por t The RS232 and USB communication ports cannot operate simultaneously. 2 1 5 6 1. Connect the RS232 (5) or USB (6) communication cable to the serial or USB port on the computer equipment. 2. Connect the other end of the commun[...]
-
Page 18
Page 16 620-00082-0 1-au (en) 4. Operation 4.1 Star t-up and Nor mal operation T o start the UPS: 1. V erify that the UPS power cord is plugged in. 2. The UPS front panel display illuminates and shows EA T ON logo. 3. V erify that the UPS status screen shows . 4. Press the button on the UPS front panel for at least 2 seconds. The UPS front panel di[...]
-
Page 19
Page 17 620-00082-0 1-au (en) ENGLISH 4. Operation Low -batt ery war ning • The and indicator illuminates solid. • The audio alarm beeps every three seconds. The remaining battery power is low. Shut down all applications on the connected equipment because automatic UPS shutdown is imminent. End of bat tery backup time • LCD displays [...]
-
Page 20
Page 18 620-00082-0 1-au (en) 5. Maintenance 5.1 T r oubleshooting Operation status Possible cause Action Batteries disconnected The UPS does not recognise the internal batteries If the condition persists, contact your service representative The batteries are disconnected Verify that all batteries are properly connected. If the condition persists, [...]
-
Page 21
Page 19 620-00082-0 1-au (en) ENGLISH 5. Maintenance 5.2 Bat t ery -module r eplacement Saf ety recommendations The battery can cause electrocution and high short-circuit cur rents. The following safety precautions are required before servicing the battery components: • remove w atches, rings, bracelets and all other metal objects from the han[...]
-
Page 22
Page 20 620-00082-0 1-au (en) Bat tery tr ay r emov al on rack models This operation must be performed when the UPS is switched OFF . A B A - Remove the middle part. B - Remove the left-hand side of the front panel by pushing the button and then by sliding the part. C C - Disconnect the battery block by separating the two connectors (never pull on [...]
-
Page 23
Page 21 620-00082-0 1-au (en) ENGLISH 6. Appendices 6.1 T echnical specications Tower 5P 650 AU 5P 850 AU 5P 1150 AU 5P 1550 AU Rack 5P 650i R 5P 850i R 5P 1150i R 5P 1550i R Output Power @ 230 V 650 VA 420 W 850 VA 600 W 1150 VA 770 W 1550 VA 1100 W Output Power @ 208 V 585 VA 378 W 765 VA 540 W 1035 VA 693 W 1395 VA 990 W Output Power @ 200 V [...]
-
Page 24
Page 22 620-00082-0 1-au (en) 6. Appendices Backup time Time during which the load can be supplied by the UPS operating on battery power. Battery test Internal UPS test to check battery status. Cold start The devices connected to the UPS can be started even if AC input power is not available. The UPS operates on battery power alone. Deep discharge [...]
-
Page 25
[...]
-
Page 26