Go to page of
Similar user manuals
-
Uninterruptible power supply (
Eaton Powerware 9140 10kVA HW
110 pages -
Uninterruptible power supply (
Eaton EX 2200VA 3U
172 pages -
Uninterruptible power supply (
Eaton Powerware 9355-15-N-15-64x9Ah
50 pages -
Uninterruptible power supply (
Eaton Ellipse MAX 1500 USBS IEC
39 pages -
Uninterruptible power supply (
Eaton Ellipse ASR XL EXB 420VA/250W
40 pages -
Uninterruptible power supply (
Eaton Powerware 9355-20-N-22-3x9Ah-MBS
56 pages -
Uninterruptible power supply (
Eaton Powerware 9155-8-S-33-64x9Ah-MBS
54 pages -
Uninterruptible power supply (
Eaton Powerware 9155-15-N-10-64x7Ah
54 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Eaton 5P850I, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Eaton 5P850I one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Eaton 5P850I. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Eaton 5P850I should contain:
- informations concerning technical data of Eaton 5P850I
- name of the manufacturer and a year of construction of the Eaton 5P850I item
- rules of operation, control and maintenance of the Eaton 5P850I item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Eaton 5P850I alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Eaton 5P850I, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Eaton service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Eaton 5P850I.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Eaton 5P850I item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
ENGLISH Copyright © 2013 EATON All rights reserved. Service and support: Call your local service representative 620-00082-02-i (en) Tower models 5P 650i 5P 850i 5P 1150i 5P 1550i 1U Rack models 5P 650i R 5P 850i R 5P 1150i R 5P 1550i R Installation and user manual[...]
-
Page 2
Page 2 620-00082-02-i (en) Cer tication Standar ds Special S ymbols The following are examples of symbols used on the UPS or accessories to aler t you to impor tant information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol. Important instructions that must always be followed. Do not discard the U[...]
-
Page 3
Page 3 620-00082-02-i (en) ENGLISH Contents 1 . Intr oduction ....................................................................................... 4 1 .1 Environmental protection ................................................................................................... 4 2. Pr esentation .................................................[...]
-
Page 4
Page 4 620-00082-02-i (en) 1. Introduction Thank you for selecting an EA TON product to protect your electrical equipment. The 5P range has been designed with the utmost care. W e recommend that you tak e the time to read this manual to take full advantage of the many features of your UPS (Uninterruptible P ower System). Before installing 5P , plea[...]
-
Page 5
Page 5 620-00082-02-i (en) ENGLISH 2. Presentation 2.1 Standar d installations T ower models D H W Description Weights (kg/ lb ) Dimensions (mm/ inch ) D x W x H 5P 650i 7.52 / 16.60 345 x 150 x 233 / 13.6 x 5.9 x 9.2 5P 850i 9.93 / 21.90 345 x 150 x 233 / 13.6 x 5.9 x 9.2 5P 1150i 10.91 / 24.10 345 x 150 x 233 / 13.6 x 5.9 x 9.2 5P 1550i 15.95 / 3[...]
-
Page 6
Page 6 620-00082-02-i (en) 2. Presentation 2.2 Tower rear panels 5P 650i 3 2 1 4 8 7 5 6a 6b 5P 850i 3 2 1 4 7 6a 6b 5 8 5P 1 150i 2 1 4 7 5 6a 3 6b 8 5P 1550i 2 1 4 5 6a 3 6b 8 7 (1) USB communication port (2) RS232 communication port (3) Slot for optional communication card (4) Connector for ROO (remote ON/OFF) or RPO (Remote Power Off) control ([...]
-
Page 7
Page 7 620-00082-02-i (en) ENGLISH 2. Presentation 2.3 Rack rear panels 5P 650i R / 5P 850i R 2 1 4 8 7 3 6a 6b 5 5P 1 150i R 6a 2 1 4 7 3 6b 5 8 5P 1550i R 6a 2 1 4 7 3 6b 5 8 (1) USB communication port (2) RS232 communication port (3) Slot for optional communication card (4) Connector for ROO (remote ON/OFF) or RPO (Remote Power Off) control (5) [...]
-
Page 8
Page 8 620-00082-02-i (en) 2. Presentation 2.4 Contr ol panel TheUPShasave-buttongraphicalLCD.ItprovidesusefulinformationabouttheUPSitself ,loadstatus, events, measurements and settings. T ower models Power On Indicator (green) On battery Indicator (yellow) Alarm Indicator (red) Normal mode 100%[...]
-
Page 9
Page 9 620-00082-02-i (en) ENGLISH 2. Presentation 2.5 LCD descr iption Operation status Load/equipment status Normal mode 100 % 10min 100% 720W 800V A Efficiency: ~98% Battery status Efficiency and load group information As default, or after 5 minutes of inactivity, the LCD displays the screen saver . The backlight LCD automatically dims after 1 [...]
-
Page 10
Page 10 620-00082-02-i (en) 2.6 Displa y functions Press the Enter ( ) button to activate the menu options. Use the two middle buttons ( and ) to scroll through the menu structure. Press the Enter ( ) button to select an option. Press the button to cancel or return to the previous menu. Menu map for Displa y Functions. Main menu Submenu Display inf[...]
-
Page 11
Page 11 620-00082-02-i (en) ENGLISH 2. Presentation Description Available settings Default settings In/Out settings Load segments - Auto shutdown delay [Disable] [0s] [1 s] [2 s]…[65354 s] During a power outage, authorises to keep some equipment running while turning off other equipment. This feature allows to save battery power. Group 1: Disable[...]
-
Page 12
Page 12 620-00082-02-i (en) 3. Installation 3.1 Unpacking and cont ents check T ower models 1 2 3 4 5 6 Rack models 2 3 5 6 8 4 7 1 (1) 5P UPS (2) Quick start and safety instructions (3) User manual and IPSS (Intelligent Power Software Suite) CDROM (4) 2 connection cables for the protected equipment (5) RS232 communication cable (6) USB communicati[...]
-
Page 13
Page 13 620-00082-02-i (en) ENGLISH 3. Installation 3.2 Installation of t o w er models 3.3 Wall installation of rack models (650i R / 850i R / 1 150i R) 1 1 2 2[...]
-
Page 14
Page 14 620-00082-02-i (en) 3.5 Installation of r ack models (850i R / 1 150i R / 1550i R) Follow steps 1 to 4 for module mounting on the rails. 3. Installation 1 1 2 2 3 3 4 4 The rails and necessary hardw are are supplied by EA TON. 3.4 Installation of r ack models (650i R only) Follow steps 1 to 3 for rack mounting. 2 3 2 3 1[...]
-
Page 15
Page 15 620-00082-02-i (en) ENGLISH 3. Installation 3.6 Communication por ts Connection of RS232 or USB communication por t The RS232 and USB communication ports cannot operate simultaneously. 2 1 5 6 1. Connect the RS232 (5) or USB (6) communication cable to the serial or USB port on the computer equipment. 2. Connect the other end of the communic[...]
-
Page 16
Page 16 620-00082-02-i (en) 4. Operation 4.1 Star t-up and Nor mal operation T o start the UPS: 1. V erify that the UPS power cord is plugged in. 2. The UPS front panel display illuminates and shows EA T ON logo. 3. V erify that the UPS status screen shows . 4. Press the button on the UPS front panel for at least 2 seconds. The UPS front panel disp[...]
-
Page 17
Page 17 620-00082-02-i (en) ENGLISH 4. Operation Low -batt ery war ning • The and indicator illuminates solid. • The audio alarm beeps every three seconds. The remaining battery power is low. Shut down all applications on the connected equipment because automatic UPS shutdown is imminent. End of bat tery backup time • LCD displays &q[...]
-
Page 18
Page 18 620-00082-02-i (en) 5. Maintenance 5.1 T r oubleshooting Operation status Possible cause Action Batteries disconnected The UPS does not recognise the internal batteries If the condition persists, contact your service representative The batteries are disconnected Verify that all batteries are properly connected. If the condition persists, co[...]
-
Page 19
Page 19 620-00082-02-i (en) ENGLISH 5. Maintenance 5.2 Bat t ery -module r eplacement Saf ety recommendations The battery can cause electrocution and high short-circuit cur rents. The following safety precautions are required before servicing the battery components: • remove w atches, rings, bracelets and all other metal objects from the hands[...]
-
Page 20
Page 20 620-00082-02-i (en) Bat tery tr ay r emov al on rack models A B A - Remove the front panel. B - Remove the left-hand side of the front panel by pushing the button and then by sliding the part. C C - Disconnect the battery block by separating the two connectors (never pull on the wires). D D - Remove the metal protection cover in front of th[...]
-
Page 21
Page 21 620-00082-02-i (en) ENGLISH 6. Appendices 6.1 T echnical specications Tower 5P 650i 5P 850i 5P 1150i 5P 1550i Rack 5P 650i R 5P 850i R 5P 1150i R 5P 1550i R Output Power @ 230 V 650 VA 420 W 850 VA 600 W 1150 VA 770 W 1550 VA 1100 W Output Power @ 208 V 585 VA 378 W 765 VA 540 W 1035 VA 693 W 1395 VA 990 W Output Power @ 200 V 585 VA 378[...]
-
Page 22
Page 22 620-00082-02-i (en)[...]