Elkay EDFP217FPC manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Elkay EDFP217FPC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Elkay EDFP217FPC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Elkay EDFP217FPC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Elkay EDFP217FPC should contain:
- informations concerning technical data of Elkay EDFP217FPC
- name of the manufacturer and a year of construction of the Elkay EDFP217FPC item
- rules of operation, control and maintenance of the Elkay EDFP217FPC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Elkay EDFP217FPC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Elkay EDFP217FPC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Elkay service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Elkay EDFP217FPC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Elkay EDFP217FPC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    97565C (Rev . J - 8/07) EDFP210FP*B EDFP214FP*B EDFP217FP*B Inst allation/Care/Use Manual EDFP210FPC EDFP214FPC EDFP217FPC Sof t Sides ™ Freeze Resist ant Fountains IMPORT ANT! INST ALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO W A TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUIL[...]

  • Page 2

    97565C (Rev . J - 8/07) EDFP210FP*B EDFP214FP*B EDFP217FP*B FIG . 1 P AGE 2 LEGEND A = MOUNTING BOL T LOCA TIONS (4) (3/8" DIA. NOT PROVIDED) B = 7/8" DIA. (22mm) HOLE FOR W A TER SUPPL Y TUBE C = 7/8" DIA. (22mm) HOLE FOR OPERA TING CABLE D = 1-3/4" (44mm) HOLE FOR W ASTE LINE FINISHED FLOOR EDFP210FP/EDFP214FP MOUNTING BOL T A[...]

  • Page 3

    97565C (Rev . J - 8/07) EDFP210FP*B EDFP214FP*B EDFP217FP*B P AGE 3 FIG . 2 FINISHED FLOOR 1. Wall should already be framed for the fountain using dimensions shown in Fig. 1. Shown dimensions pertain to installation location. These dimensions are required for compliance with ANSI S tandard A1 17.1. and ADA (Framing shown for reference only). 2. Rem[...]

  • Page 4

    97565C (Rev . J - 8/07) EDFP210FP*B EDFP214FP*B EDFP217FP*B FINISHED FLOOR P AGE 4 FIG . 3 LEGEND A = 3/8" DIA. (10mm) SLOTS (FOR MOUNTING UPPER HANGER BRACKET) B = 7/8" DIA. (22mm) HOLE FOR W A TER SUPPL Y TUBE C = 7/8" DIA. (22mm) HOLE FOR OPERA TING CABLE D = MOUNTING BOL T LOCA TIONS (8) (3/8" DIA. NOT PROVIDED) E = 1-3/4&qu[...]

  • Page 5

    97565C (Rev . J - 8/07) EDFP210FP*B EDFP214FP*B EDFP217FP*B 1. Wall should already be framed for the fountains using dimensions shown in Fig. 3. Shown dimensions pertain to installation location. These dimensions are required for compliance with ANSI S tandard A1 17.1. and ADA (Framing shown for reference only). 2. Remove bottom covers from fountai[...]

  • Page 6

    97565C (Rev . J - 8/07) EDFP210FP*B EDFP214FP*B EDFP217FP*B P AGE 6 FIG . 8 FIG . 9 FIG . 5 FIG . 6 See Fig. 9 See Fig. 5 FIG . 7 CABLE SHEA TH ADJUSTMENT T o Increase Free Play T o Reduce Free Play[...]

  • Page 7

    97565C (Rev . J - 8/07) EDFP210FP*B EDFP214FP*B EDFP217FP*B P AGE 7 The freeze resistant package must be mounted on an interior wall in a heated area. The room temperature of the interior heated area must be 50° F (10° C) or higher . The freeze resist ant package may be surface or recessed mounted. If recess mounted the surface of the cover must [...]

  • Page 8

    97565C (Rev . J - 8/07) EDFP210FP*B EDFP214FP*B EDFP217FP*B P AGE 8 FOR P ARTS, CONT ACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKA Y MANUF ACTURING COMP ANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 P ART NO. ITEM NO. P AR TS LIST GASKET SCREW-#10 X .50 PINNED TORX NIPPLE ASSY BRACKET -REGULA TOR MOUNTING BRACKET -BASI[...]