Emerson Process Management 396P manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson Process Management 396P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson Process Management 396P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson Process Management 396P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson Process Management 396P should contain:
- informations concerning technical data of Emerson Process Management 396P
- name of the manufacturer and a year of construction of the Emerson Process Management 396P item
- rules of operation, control and maintenance of the Emerson Process Management 396P item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson Process Management 396P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson Process Management 396P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson Process Management service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson Process Management 396P.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson Process Management 396P item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Combina tion pH/ORP Sensor Instruction Manual PN 51-396P/rev .H March 2006 MODEL 396P MODEL 396PVP with mating cable Models 396P and 396PVP[...]

  • Page 2

    CAUTION SENSOR/PROCESS APPLICA TION COMP A TIBILITY The wetted sensor materials may not be comp atible with process composition and operating conditions. Application comp atibility is entirely the responsibility of the user . DANGER HAZARDOUS AREA INST ALLA TION This sensor is not Intrinsically Safe. or Explosion Proof. Installations near flammable[...]

  • Page 3

    i MODEL 396P and 396PVP T ABLE OF CONTENTS MODEL 396P and 396PVP COMBINA TION pH/ORP SENSOR T ABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICA TIONS ................................................................. 1 1.1 Features and Applications ......................................................................................[...]

  • Page 4

    MODEL 396P and 396PVP T ABLE OF CONTENTS LIST OF FIGURES Number Title Page 1-1 Cross Section Diagram of the TUpH Patented Reference T echnology ............................................................................... 2 2-1 Dimensional Drawing ....................................................................................................[...]

  • Page 5

    Model 396PVP is of fered with a watertight sensor-to- cable connector which eliminates re-wiring and cable twisting when replacing sensors. The V ariopol VP multiple pin connector is an integral part of each sen- sor model and uses a mating VP cable. Once the cable is installed and wired to the analyzer , sensors are easily replaced without replaci[...]

  • Page 6

    2 MODEL 396P and 396PVP SECTION 1.0 DESCRIPTIONS AND SPECIFICA TIONS Measurement s and Ranges *pH: 0-14 ORP: -1500 to 1500 mv A vailable pH A CCU G LASS T ypes GPLR hemi or flat glass Wetted Materials T itanium, Polypropylene, EPDM, glass; platinum (ORP only) Process Connection 1 in. MNPT front and rear facing threads T emperature Range 0-100°C (3[...]

  • Page 7

    3 MODEL 396P and 396PVP SECTION 1.0 DESCRIPTIONS AND SPECIFICA TIONS 1.3 ORDERING INFORMA TION The Model 396P Sensor is housed in a molded reinforced polypropylene body with 1 in. MNPT threads suit able for insertion, submersion or flow through installation. The sensor includes a general purpose pH electrode or a platinum ORP electrode, a p atented[...]

  • Page 8

    4 MODEL 396P and 396PVP SECTION 1.0 DESCRIPTIONS AND SPECIFICA TIONS Optional Slotted Tip is available on all hemi bulb sensors, ordered as option -41 Flat Tip is avail- able with flat glass bulb sen- sors Examples of all sensing tip offerings Shrouded Tip is standard on all hemi bulb sensors V ariopol connector shown with mating variopol cable rec[...]

  • Page 9

    5 MODEL 396P and 396PVP SECTION 2.0 INST ALLA TION SECTION 2.0 INST ALLA TION 2. Do not install the sensor on the horizont al. The sensor must be 10° off the horizont al to ensure accuracy . 3. Do not install the sensor up side down. 4. Air bubbles may become trapped in the sensor end between the glass bulb and the sensor body . This problem is mo[...]

  • Page 10

    6 MODEL 396P and 396PVP SECTION 2.0 INST ALLA TION FIGURE 2-1. Dimensional Drawing DWG . NO. REV . 40396P01 D MILLIMETER INCH FIGURE 2-2. Flow-Through T ee with Adapter (PN 915240-xx*) MILLIMETER INCH xx* Process Connection Threads 03 3/4 inch 04 1 inch 05 1-1/2 inch SENSOR CABLE (OR VP CONNECTOR - NOT SHOWN) SENSOR CABLE (OR VP CONNECTOR - NOT SHO[...]

  • Page 11

    MODEL 396P and 396PVP SECTION 2.0 INST ALLA TION FIGURE 2-4. Model 396P with Insertion Mounting Adapter (PN 23242-02). Not for use with Model 396PVP . Mounting adapter allows for sensor removal without twisting or disconnecting interconnecting cable for ease of maintenance. WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH DWG . NO. REV . 40396P0[...]

  • Page 12

    MODEL 396P and 396PVP SECTION 2.0 INST ALLA TION FIGURE 2-5. Submersion Inst allations WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH DWG . NO. REV . 40396P04 A DWG . NO. REV . 40396P03 A Handrail Mounting Assembly PN 1 1275-01 8[...]

  • Page 13

    9 MODEL 396P and 396PVP SECTION 2.0 INST ALLA TION FIGURE 2-6. Low Flow Cell PN 23728-00 MILLIMETER INCH FIGURE 2-7. Jet Spray Cleaner PN 12707-00 SENSOR CABLE (OR VP CONNECTOR - NOT SHOWN)[...]

  • Page 14

    10 Figures in this section provide the guidelines for wiring the 396P-01 sensor to various Analyzer/Transmitter instruments. T o determine which wiring guideline to use, locate the model number of the sensor to be installed. 1. If the cable needs to be extended, use a high qual- ity eleven conductor double shielded instrument cable available from R[...]

  • Page 15

    11 MODEL 396P and 396PVP SECTION 3.0 WIRING - MODEL 396P Wiring. The Model 396P has an optional built-in pre- amplifier and is offered with a shielded cable. The cable should be handled carefully and kept dry and free of corrosive chemicals at all times. Extreme care should be used to prevent it from being twisted, dam- aged or scraped by rough, sh[...]

  • Page 16

    12 MODEL 396P and 396PVP SECTION 3.0 WIRING - MODEL 396P FIGURE 3-2. Wiring Det ails Model 396P-01-50 for use with and without Junction Box (PN 22719-02) for Model 1 181. WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH DWG . NO. REV . 40396P15 B[...]

  • Page 17

    13 FIGURE 3-3. Wiring Det ails Model 396P-01-54 for use with and without Junction Box (PN 22719-02) for Models 1054A, 1054B, 2054, 2081, and Extension Cable (9200254). MODEL 396P and 396PVP SECTION 3.0 WIRING - MODEL 396P DWG . NO. REV . 40396P13 D WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH[...]

  • Page 18

    14 MODEL 396P and 396PVP SECTION 3.0 WIRING - MODEL 396P FIGURE 3-4. Wiring Det ails Model 396P-01-55 for use with Junction Box (PN 23550-00) for Models 54e, 3081, 4081, 81, and 5081. WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH DWG . NO. REV . 40396P08 B[...]

  • Page 19

    15 MODEL 396P and 396PVP SECTION 3.0 WIRING - MODEL 396P FIGURE 3-5. Wiring Det ails Model 396P-01-55 for use with Models 54e, 81, 3081, 4081, and 5081 FIGURE 3-6. Wiring Model 396P-01-( )--55 Sensor to Model 1055-10-22-32 Analyzer[...]

  • Page 20

    16 Figures 4-1 thru 4-22 provide the guidelines for wiring the sensor to various Analyzer/Transmitter instrument s. T o determine which wiring guideline to use, locate the model number of the sensor to be installed. 1. If the cable needs to be extended, use a high qual- ity eleven conductor double shielded instrument cable available from Rosemount [...]

  • Page 21

    MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-1. Wire Functions for Mating V ariopol Cable used with Model 396PVP FIGURE 4-2. Connector Pins and Their Functions FIGURE 4-3. Wiring Det ails for Models 396PVP or 396P-02-55 with Mating V ariopol Cable (PN 23645-07) for use with Model 81 FIGURE 4-4. Wiring Det ails for Models 396PVP [...]

  • Page 22

    18 MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-8. Wiring Det ails for Models 396PVP or 396P-02-50 with Mating V ariopol Cable (PN 23645-06) for use with Remote Junction Box (PN 23309-03) to Model 1 181 FIGURE 4-7. Wiring Det ails for Models 396PVP or 396P-02-55 with Mating V ariopol Cable (PN 23645-07) for use with Remote Junct[...]

  • Page 23

    MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-12. Wiring Det ails for Models 396PVP or 396P-02-55 with Mating V ariopol Cable (PN 23645-07) for use with Remote Junction Box (PN 23555-00) to Models 3081, 4081, & 5081 FIGURE 4-1 1. Wiring Details for Models 396PVP or 396P- 02-54 with Mating V ariopol Cable (PN 23645-06) for use[...]

  • Page 24

    MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-15. Wiring Det ails for Models 396PVP or 396P-02-55 with Mating V ariopol Cable (PN 23645-07) for use with Model 1055 FIGURE 4-16. W iring Model 396P-(02)-( )--54/55-(61) Sensor to Model 1055-01-10-22-32 Analyzer FIGURE 4-17. Wiring Det ails for Models 396PVP or 396P-02-55 with Mating[...]

  • Page 25

    MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-18. Wiring Det ails for Models 396PVP or 396P-02-54 with Mating V ariopol Cable (PN 23645-06) for use with Models 1054A/B & 2054 FIGURE 4-19. Wiring Det ails for Models 396PVP or 396P-02-54 with Mating V ariopol Cable (PN 23645-06) for use with Remote Junction Box (PN 23309-04) to[...]

  • Page 26

    22 MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-21. Wiring Det ails Model 396P-02-50 for use with Junction Box (PN 23309-03) and Remote Preamplifier , Extension Cable (PN 9200254). DWG . NO. REV . 40396P25 A FIGURE 4-22. Wiring Det ails Model 396P-02-54 for use with Junction Box (PN 23309-04) and Remote Preamplifier (PN 22698-03[...]

  • Page 27

    MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-23. Wiring Model 396P-01 to Model Xmt-P-HT -10 FIGURE 4-24. Wiring Models 396P-02 and 396PVP to Model Xmt-P-HT -10 23[...]

  • Page 28

    1. While obtaining a process solution sample (it is recommended that the sample is taken close to the sensor), record the pH value that is shown on the analyzer/transmitter display . 2. Measure and record the pH of the process solution sample with another temperature compensated, calibrated pH instrument. For best results, st andardization should b[...]

  • Page 29

    25 MODEL 396P and 396PVP SECTION 6.0 MAINTENANCE The Model 396P and 396PVP Sensors require mini- mum maintenance. The sensor should be kept clean and free of debris and sediment at all times. The fre- quency of cleaning by wiping or brushing with a soft cloth or brush is determined by the nature of the solu- tion being measured. The sensor should b[...]

  • Page 30

    26 MODEL 396P and 396PVP SECTION 6.0 MAINTENANCE 6.3 MODEL 396P and 396PVP ORP 4.3.1 Platinum Electrode Check. The platinum elec- trode may be checked as follows: There are two types of standard solutions which may be used to check the ORP electrode/transmitter system. T ype 1: One type of commonly used ORP st andard solution is the saturated quinh[...]

  • Page 31

    27 MODEL 396P and 396PVP SECTION 7.0 DIAGNOSTICS AND TROUBLESHOOTING SECTION 7.0 DIAGNOSTICS AND TROUBLESHOOTING 7.1 MODEL 54e/81/3081/4081/5081/Xmt DIAGNOSTICS AND TROUBLESHOOTING The Model 54 Analyzer and Models 81 and 3081 T ransmitters automatically search for fault conditions that would cause an error in the measured pH value, as does the Mode[...]

  • Page 32

    28 7.2 TROUBLESHOOTING WITHOUT ADV ANCED DIAGNOSTICS. T able 7-2, below , lists common problems, causes and remedies typically encountered in process measurement. Problem Probable Cause Remedy Meter reads off scale. (Display Defective preamplifier Replace preamplifier (for code 02 reads overrange). sensors). For code 01, replace sensor . T .C. elem[...]

  • Page 33

    29 MODEL 396P and 396PVP SECTION 7.0 TROUBLESHOOTING T ABLE 7-3. Model 396P and 396PVP pH/ORP Replacement Parts and Accessories PN DESCRIPTION QUANTITY 1 1275-01 Sensor Handrail Mounting Assembly 200201 1 Flow Cell, CPVC, 1 inch FNPT 23242-02 Mounting Adapter , Insertion, 1¼-inch MNPT (304 S.S.) X 1” FNPT (PEEK) 23309-03 Junction Box, for remote[...]

  • Page 34

    30 MODEL 396P and 396PVP SECTION 8.0 RETURN OF MA TERIAL SECTION 8.0 RETURN OF MA TERIAL 8.1 GENERAL. T o expedite the repair and return of instruments, prop- er communication between the customer and the fac- tory is important. Before returning a product for repair , call 1-949-757-8500 for a Return Materials Authorization (RMA) number . 8.2 W ARR[...]

  • Page 35

    W ARRANTY Seller warrants that the firmware will execute the programming instructions provided by Seller , and that the Goods manufactured or Services provided by Seller will be free from defects in materials or workmanship under normal use and care until the expira- tion of the applicable warranty period. Goods are warranted for twelve (12) months[...]

  • Page 36

    Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .raihome.com Specifications subject to change without notice. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA T el: (949) 757-8500 Fax: (949) 474-7250 http://www .r[...]