Go to page of
Similar user manuals
-
Thermostat
Emerson 1F80ST-0471
2 pages 0.15 mb -
Thermostat
Emerson 1HDEZ-1521
32 pages 2.06 mb -
Thermostat
Emerson 1F85ST-0422
2 pages 0.16 mb -
Thermostat
Emerson 5C06
2 pages 0.06 mb -
Thermostat
Emerson 1E78-140
2 pages 0.24 mb -
Thermostat
Emerson 1F98EZ-1621
12 pages 3.31 mb -
Thermostat
Emerson 90 SERIES 1F95-391
44 pages 2.73 mb -
Thermostat
Emerson 1F95EZ-0671
8 pages 0.85 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson 1f86-0244, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson 1f86-0244 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson 1f86-0244. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson 1f86-0244 should contain:
- informations concerning technical data of Emerson 1f86-0244
- name of the manufacturer and a year of construction of the Emerson 1f86-0244 item
- rules of operation, control and maintenance of the Emerson 1f86-0244 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson 1f86-0244 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson 1f86-0244, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson 1f86-0244.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson 1f86-0244 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Le thermostat est conçu pour usage a vec une installation à basse ten- sion de classe II (CCÉ). Ne pas l’utiliser av ec un système à la tension du réseau. En cas d’incer titude à savoir si le câblage est en millivolts, à basse tension ou à la tension du secteur , le faire inspecter par un électricien ou un entrepreneur agréé. Ne pa[...]
-
Page 2
2 INST ALLA TION DÉMONT A GE DE L ’ANCIEN THERMOST A T 1. P endant l’installation, couper le courant au panneau de distribution principal. S’assurer que le courant a bel et bien été coupé. 2. Détacher le boîtier de l’ancien thermostat. Alors que les fils y sont encore reliés, détacher le socle du mur [...]
-
Page 3
3 SCHÉMAS DE CÂBLA GE R C 24 V CA 120 V CA Sous tension Neutre THERMOS TAT SYSTÈME G W Figure 2. Schéma de câblage typique , installation à un étage a vec transf ormateur unique TRANSFORMA TEUR (classe II, courant restreint) Relais inv erseur* Y O/B Contacteur de compresseur * Relais inv erseur alimenté en CLIMA TISA TION lorsque le commuta[...]
-
Page 4
4 PRÉSENT A TION DU THERMOST A T A vant d’utiliser le thermostat, il est impor tant de se familiariser av ec sescaractéristiquesetson afcheurainsiqu’av ecl’emplacementet le mode d’emploi de ses touches et de ses commutateurs (gure 5). Le[...]
-
Page 5
5 Référence du menu Appuyer sur Affichage (valeur par défaut) Appuyer sur ou pour choisir un réglage Remarques 7 et T emp (0HI) 4LOÀ 4HI Réglageàlahausseouàlabaissedelatempératureafchée 8 et °F °C Réglagedesunitésafchées(°Cou°F) 9 et ChangeFilter (OFF) On R[...]
-
Page 6
6 FONCTIONNEMENT VÉRIFICA TION DE FONCTIONNEMENT Lors des essais du système, communiquer avec un technicien agréé si quoi que ce soit ne fonctionne pas correctement. Rétablirlecourantquialimentelesystème . V entilateur Si l’installation n’est pas dotée d’une bor ne G , passer directement à la section Chauffage . 1. ?[...]
-
Page 7
7 DÉP ANNA GE Réinitialisation Si une pointe de tension ou une décharge d’électricité statique efface l’afcheur ou cause un fonctionnement imprévisible du ther mostat, il peut être nécessaire de réinitialiser celui-ci : régler le commutateur SYSTEM à COOL ou à HEA T , puis appuyer simultanément s[...]
-
Page 8
www .white-rodgers.com White-Rodgersestunedivision d’Emerson Electric Co. Le logo Emerson est une marque de commerce et de service d’Emerson Electr ic Co . Soutien aux propriétaires : 1-800-284-2925[...]