A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson 1HDEZ-1521, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson 1HDEZ-1521 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson 1HDEZ-1521. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson 1HDEZ-1521 should contain:
- informations concerning technical data of Emerson 1HDEZ-1521
- name of the manufacturer and a year of construction of the Emerson 1HDEZ-1521 item
- rules of operation, control and maintenance of the Emerson 1HDEZ-1521 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson 1HDEZ-1521 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson 1HDEZ-1521, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson 1HDEZ-1521.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson 1HDEZ-1521 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
T ROUBLESHOOTING 1HDEZ-1 52 1 Emerson Inspire ™ Thermosta t/Interf ace Equipment Control Ins talla tion Ins tructions[...]
-
Page 2
2 A TTENTION: MERCURY NO TICE This product does not contain mercury . However , this product may replace a product that contains mercury . Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury . W earing non-absorbent gloves, clean up any spilled mercury and place in a sealed container . [...]
-
Page 3
3 APPLICATIONS & SPECIFICATIONS Applications and Speci cations Electrical Rating: Input-Hardwire .............................. 20 to 30 VA C T erminal Load ............................... 1.0 A per terminal, 2.5 A maximum all terminals combined Setpoint Range ............................. 45° to 99°F (7° to 37°C) Di erential (Single [...]
-
Page 4
4 INSTALLATION Installation Reduce installation time with a USB 1. Go to www .white-rodgers.com 2. Enter 1HDEZ-1521 in the Model Number Search eld 3. Select the link for the USB download tool and follow instructions Upload pre-con gured thermostat settings for every job! Create custom messages for your rou- tine maintenance and service calls[...]
-
Page 5
5 INSTALLATION Equipment Control Mount on wall or exterior surface of HV AC equipment. Control has four mounting holes. Wall anchors and screws are provided for mounting on dry- wall. Drill 3/16 " hole for drywall mounting. If mounting on equipment Do Not Mount inside HV AC equipment. Only mount on outside of HV AC equipment. Gas Furnace Equip[...]
-
Page 6
6 INSTALLATION Equipment Control T erminals Operation / Function R ................................................ 24 V AC T ransformer RC .............................................. 24 V AC Cooling T ransformer* RH ............................................. 24 V AC Heating T ransformer* C ................................................ 24 [...]
-
Page 7
7 INSTALLATION RJ- 11 Connection for Configuration Plug-In tool Status/Fault 7 -S egment LED Wiring to Thermostat R and C from HV AC terminal strip or system transformer Wiring to Sensor Wiring to indoor/outdoor equipment W/E W2 Y Y2 G O/B L HM HM2 DHM DHM2 RC RH R C LED push button switch + S - R 1 2 C Wiring to humidification equipment Wiring t[...]
-
Page 8
8 INSTALLATION Installation Fig. 1 - T ypical Connection of a Single Stage or Multi- Stage System *Factory installed jumper between RH and RC SYSTEM R RH RC C W/E W 2 Y Y 2 G O/B L Single Stage 24 VA C P ower 24 VAC P ower for Heating 24 VA C P ower for Cooling 24 VA C Common Required Heat N/A Cool N/A Fan N/A System Monitor Multi Stage 24 VA C P o[...]
-
Page 9
9 INSTALLATION Installation Wiring Guide for Equipment Accessories HM HM 2 Non-P owered Humidier T ransformer R C HM DRY RH HM 2 Fig. 3 - Humidier . HM terminal provides system 24V on call for humidication Fig. 4 - P owered Humidier . With HM DRY switch in HM 2 position, HM and HM 2 provide normally open dry contact for low voltage ( 24[...]
-
Page 10
10 INSTALLATION Installation Fig. 6 - System Dehumidication with variable speed blower . For systems where low speed requires connect to normally open 24 V powered DHM terminal for low speed connection on air handler/furnace ( 24 V removed on dehumidication call). Wiring Guide for Equipment Accessories DHM DHM 2 Low Speed Fan T ransformer R C[...]
-
Page 11
11 INSTALLATION Installation Thermostat 1) Pull the thermostat o the base using tabs shown above. 2) Place base over wire hole in wall and mark mounting hole locations using base as a template. Drill mounting holes. 3) Fasten base snugly to wall using wall anchors and two mounting screws. Leveling is for appearance only and will not aect ther[...]
-
Page 12
12 INSTALLATION Thermostat E quipment Control R 1 2 C 1 2 C R Data 1 Data 2 24 V AC (Common 24 VA C (Hot) Fig. 8 - Thermostat and Equipment Control Wiring RJ- 11 Connection for Configuration Plug-In tool Status/Fault 7 -S egment LED Wiring to Thermostat R and C from HV AC terminal strip or system transformer Wiring to Sensor Wiring to indoor/outdo[...]
-
Page 13
13 AD V ANCED INSTALLER MENU From the Home screen press the and buttons at the same time for three seconds. Press Enter button to save any changes and display the previous menu or press Home to display the Home Screen. Items on the Advanced Installer Menu are: Communicating Devices – select system conguration options Fault Status ?[...]
-
Page 14
14 AD V ANCED INSTALLER MENU Press button to select Setup . Communicating Devices This menu item will list each piece of system equipment. Press button to select start Communicating Devices . Press button to select Equipment Control . Advanced Installer Menu[...]
-
Page 15
15 AD V ANCED INSTALLER MENU Indoor GA 2 – 2 stage gas furnace GA 1 – 1 stage gas furnace EL 2 – 2 stage electric heat EL 1 – 1 stage electric heat F AN – Indoor fan only Outdoor AC 2 – 2 stage A/C unit AC 1 – 1 stage A/C unit HP 2 – 2 stage heat pump HP 1 – 1 stage heat pump ACO – no outdoor equipment Rev Valve O – use if “[...]
-
Page 16
16 AD V ANCED INSTALLER MENU HUM OFF – No humidier equipment SYS – Humidier , powered using 24 V from system IND – Humidier , powered using independent 24 V source DHM OFF – No dehumidier equipment SYS – Dehumidier , powered using 24 V from system IND – Dehumidier , powered using independent 24 V source LEDs on the con[...]
-
Page 17
17 AD V ANCED INSTALLER MENU USB Upload The USB Upload menu displays a list of thermostat parameters that can be loaded to the thermostat from a USB memory device. If the USB port detects a USB memory device, this menu will automatically display . In the USB Upload menu, select the item to upload and press to mark the item with a red box. After all[...]
-
Page 18
18 AD V ANCED INSTALLER MENU Thermostat Summary Indicates the thermostat’ s software and version. Heat Pump Lockout ( outdoor sensor required) Available only for heat pump systems with indoor electric heat. This feature disables the heat pump and turns on auxiliary heat below the selected outdoor temperature. The temperature range is from 5° to [...]
-
Page 19
19 AD V ANCED INSTALLER MENU Aux Lockout T emperature (outdoor sensor required) Available for heat pump systems. This setting is the maximum outdoor temperature that is acceptable for auxiliary heat to be used. Heat C ycle Rate Anticipation for heat cycle can be adjusted. Default setting is Medium . If you wish to have longer heat cycles, change to[...]
-
Page 20
20 AD V ANCED INSTALLER MENU Installation T est P erforms an equipment test to verify proper installation and performance. Only operable on communicating systems with ClimateT alk™. Check System Operation Heating System 1. Press SYSTEM button until Heat is displayed. 2. Press to adjust thermostat setting 1° above room temperature. The heating sy[...]
-
Page 21
21 MAIN MENU Navigating through your thermostat menus Y our thermostat features a simplied easy to understand menu structure. • Press to enter the Main Menu • Highlight a menu item using the or buttons • Enter the item by pressing • Use the or and the or to change menu items and settings • Press the Home button to display the Home Scre[...]
-
Page 22
22 MAIN MENU Time and Day Display When turned on, the current time and day are displayed on the home screen. Outdoor T emp Display When turned on, the outdoor temperature is displayed on the home screen (for use with outdoor sensor only). Humidity Display When turned on, the sensed humidity is displayed on the home screen. Alert Info Detail When tu[...]
-
Page 23
23 MAIN MENU Cooling Program After entering Heating Program, press to highlight “Switch to Cool Program” and press , or enter Cooling Program on the Main Menu . Factory Pre-Programmed Heating and Cooling Schedule Wake Up (Morning) Leave for Work (Day) Return Home (Evening) Go to Bed (Night) Heating Program 6:00 AM 70 o F 8:00 AM 62 o F 5:00 PM [...]
-
Page 24
24 MAIN MENU Air Filter Maintenance / Service Reminder / Humidier Maintenance Default for each is O . When set to On , a maintenance reminder will appear on the home screen when the system has run for the selected amount of time. The length of time for the maintenance reminder can be selected to a setting of 1 to 12 months. Use or . to select[...]
-
Page 25
25 MAIN MENU Beeper – Default is On . T urns audible prompt on to indicate when a button is pressed. C ycle Humidier – Default if O . This feature provides an option that reduces the water usage by up to 50% when a ow-through humidier is controlled by the thermostat. It is recommended for use on ow-through humidiers only . Whe[...]
-
Page 26
26 MAIN MENU EMR (Energy Management Recovery) Default is On . With EMR selected On , the heating or cooling system will start early so the temperature in your home is at the desired temperature at the beginning of the program period. If set to O , the system will not start until the beginning of the program period. Maximum Heat Setpoint T emp. D[...]
-
Page 27
27 MAIN MENU T emperature Display Adjust – Default is 0° . Y our thermostat was accurately calibrated at the factory . However , this option allows you to change the humidity or temperature displayed to match other thermostats in your home. Dehumidication Setpoint – Default is 95% . Setpoint is the percent humidity that the cooling system w[...]
-
Page 28
28 T ROUBLESHOOTING Symptom P ossible Cause Correction Action No Heat/No Cool/ No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. P ower switch to OFF . 3. Furnace blower compartment door or panel loose or not properly installed. 4. Loose connection to system. Replace fuse or reset break er . T urn switch to ON. Replace door pan[...]
-
Page 29
29 T ROUBLESHOOTING Symptom P ossible Cause Correction Action No Cool 1. Cooling system requires service. Heat, Cool or Fan Runs Constantly 1. P ossible short in wiring. 2. P ossible short in thermostat. 3. P ossible short in heat/ cool/fan system. 4. F AN Switch set to Fan ON. Check each wire connection to verify they are not shorted or touching t[...]
-
Page 30
30 T ROUBLESHOOTING Equipment Control Fault Codes Number Displayed in 7 Segment LED Comfort Alert Fault P T rip 1 Long Run Time 2 System Pressure T rip 3 Short C ycling 4 Locked R otor 5 Open Circuit 6 Open Start Circuit 7 Open Run Circuit 8 W elded Contactor 9 Low V oltage System Communication Codes E Communication Error C For 30 seconds after Com[...]
-
Page 31
[...]
-
Page 32
www. white-rodgers.com www.emersonclimate.com White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. P ART NO. 37-7343 B Replaces 37-7343A 1312[...]