Go to page of
Similar user manuals
-
Power Supply
Emerson GXT2U
40 pages 1.21 mb -
Power Supply
Emerson 40-120KVA
2 pages 0.25 mb -
Power Supply
Emerson 1500
32 pages 1.58 mb -
Power Supply
Emerson AXP1406
148 pages 3.53 mb -
Power Supply
Emerson 208V
80 pages 6.23 mb -
Power Supply
Emerson 650VA
2 pages 0.63 mb -
Power Supply
Emerson 000-VA
48 pages 5.58 mb -
Power Supply
Emerson 400KVA
79 pages 2.85 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson 208V, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson 208V one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson 208V. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson 208V should contain:
- informations concerning technical data of Emerson 208V
- name of the manufacturer and a year of construction of the Emerson 208V item
- rules of operation, control and maintenance of the Emerson 208V item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson 208V alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson 208V, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson 208V.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson 208V item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
AC P ow er For Business-Criti cal C on tinuity™ Li eb er t ® GX T3 ™ UPS 120V/208V 500V A-3000V A User Ma nual[...]
-
Page 2
[...]
-
Page 3
i T ABLE OF CONTENTS I MPORT ANT S AFETY P RECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 S AVE T HESE I NSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 4
ii 4.0 O PERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.1 Startup Checklist for the Liebert GXT3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.2 Starting the UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 5
iii FIGURES Figure 1 Liebert GX T3 rack/tower models— front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 2 Liebert GX T3 minitower—front vie w . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 3 Liebert ® GXT3 ™ 120V rack/tower models?[...]
-
Page 6
iv[...]
-
Page 7
1 I MPORT ANT S AFETY P RECAU TIONS SAVE THESE INSTRUCTIONS This manual contains im portant safety instructions that must be followed du ring the installation and maintenance of the UPS and batteries. Read this manual thoroughly before attempting to install or operate this UPS. UPS Safety Notes This UPS contains no user-serviceable parts except the[...]
-
Page 8
2 The Liebert ® GXT3 ™ -3000RT208 was tested under 20A bran ch circuit in accordance with the National Electri cal Code, ANSI/NFPA 70. To red uce th e risk of fire, connect on ly to a circuit provided with 20A maximum branch overcurrent protection. Battery Safety ELECTROMAGNETIC COM PATIBILITY —The Liebert GXT3 complies with the limits for a C[...]
-
Page 9
3 G LOSSARY OF S YMBOLS Risk of ele ctrical shock Indicates caution followed by important instructions AC input AC output Requests the user to consult the manual Indicates the unit contains a valve-regulated lead acid battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage ON/Alarm Silence/Battery Test OFF/Bypass WEEE ![...]
-
Page 10
Product De scription 4 1.0 P RODUCT D ESCRIPTION The Liebert ® GXT3 ™ is a compact, online uninterruptible power system (UPS) that continuously conditions and regulates its outpu t voltage. The Lie bert GXT3 is designed to supply microcomput ers and other sensitive equipment with clean sine wave input po wer. Upon generation, AC power is clean a[...]
-
Page 11
Product De scription 5 1.3 Appearance and Component s 1.3.1 Front Panel and Controls The Liebert ® GXT3 ™ rack/tower and minitower models in various power ratings have the same general appearance, controls and features ( see Figure 1 ). The various rack/tower and minitower models differ largely in the type of receptacles each has. Figure 1 Liebe[...]
-
Page 12
Product De scription 6 Figure 3 Liebert ® GXT3 ™ 120V rack/tower models—rear p anel component s Input Power Plug and Cable 5-15P External Battery Connector T erminal Block Communication USB Port Input Circuit Breaker Output Receptacles, 5-15R 500V A, 700V A, 1000 V A, 1500V A Models Input Power Plug and Cable, 5-20P External Battery Connector [...]
-
Page 13
Product De scription 7 Figure 4 Liebert ® GXT3 ™ 208V rack/tower models—rear p anel component s Figure 5 Liebert GXT3-1000MT120 ™ —rear p anel component s 3000V A Mode l Input Power Plug and Cable, L6-2 0P External Battery Connector USB Port Cooling Fan Input Circuit Breaker Output Receptacle, L6-20R Output Circuit Breakers Liebert Intelli[...]
-
Page 14
Product De scription 8 1.4 Major Component s The operating princi ple of the UPS is illustrated in Figure 6 . Figure 6 Operating principle dia gram The UPS is compo sed of utility input, TVSS and EMI/RFI fi lters, rectifier/PFC, inverter, battery charger, DC-to-DC converter, batte ry, dynamic bypass and UPS output. T ransient V olt age Surge Suppre[...]
-
Page 15
Product De scription 9 Battery Charger The battery charger utilizes energy from the utilit y power and precisely regulates it to continuously float charge the batteries. The batteries are being cha rged wheneve r the Liebert ® GXT3 ™ is plugged in, even when the UPS is not turned On. DC-to-DC Converter The DC-to-DC converter raises the D C volta[...]
-
Page 16
Product De scription 10 1.5.3 Battery Mode The Liebert ® GXT3 ™ enters Battery Mode wh en utility powe r fails or is outside acceptabl e values. The battery system supplies power th rough the DC-to-DC converte r to the inverter to generate clean AC power for the connected loads. When the Liebert GXT3 enters Battery Mode, th e UP S sounds a half-[...]
-
Page 17
Installation 11 2.0 I NST ALLATION 2.1 Unp acking and Inspection Unpack the UPS and conduct the following checks: • Inspect the UPS f or shipping damage. If any shipping dama ge is found, report it to the carrier and your local dealer or your Emer son representative immediately. • Check the accessories included in packaging list. If th ere is a[...]
-
Page 18
Installation 12 2.4 Mechanical Inst allation The Liebert ® GXT3 ™ may be installed as a tower or in a rack, depending on space and use considerations. The Liebert GXT3 ma y be used alone, as a single UPS, or with up to four battery cabinets. 2.4.1 T ower Installation To install the Liebe rt GXT3 as a tower: 1. Take out support bases from the acc[...]
-
Page 19
Installation 13 Figure 9 Rot ate the operation and display p anel c. Pull the logo on the front plastic bezel cover ge ntly, rotate it 90 degrees cl ockwise and snap it back into position . The rotated front plastic be zel cover is shown in Figure 10 . d. Replace the front plastic bezel cover on the Lie bert ® GXT3 ™ . At this point, the UPS ope[...]
-
Page 20
Installation 14 2.4.2 Rack Inst allation To install a Liebert GXT3 rack/tower UPS in a rack: 1. Unpack the two slide rails assemblies and mo unting hardware from the rack-mounting kit (P/N: RMKIT18-3 2). Slide rail as sembly includes inn er member and front and rear members. They are interchange- able between left-hand or right-hand. Mounting hardw[...]
-
Page 21
Installation 15 5. Ex tend the slide rail assembly by sliding the front member forward until it touches the rack’s front vertical rails (ad justable length: 18 to 32 inches [4 57-813mm]). Use two M5 screws to fix each front member onto the front vertical rails through the instal lation holes. Make sure that slide rail assemblies are at the same m[...]
-
Page 22
Installation 16 Figure 16 Inst alling rack-mount handles 9. Insert the UPS, with inner me mbers attached, into sli de rail assemblies b y inserting top and bottom edges of inner members into the top and bottom, curved tracks of front members and sliding the UP S into rack, as shown in Figure 17 . Figure 17 Insert the UPS 10. Through the rack mount [...]
-
Page 23
Installation 17 2.5 Cable Connection The Liebert ® GXT3 ™ rear panel has an input cable an d plug, output receptacles and output cable(s) (Output cables are on GXT3-3 000 models onl y). Refer to 1.3.2 - Rear Panel Features for details. The battery cables are suppli ed with the battery cabinet. 2.5.1 Connecting Input Plug and Loads The specificat[...]
-
Page 24
Installation 18 2.6 Connecting Communication Cables Communication cable connect ion includ es: USB and ca bles for option cards. 2.6.1 Connecting USB Communication Cable s 1. Take the USB communi cation cables out of the accessories box. 2. Ins ert one end of the USB communication cable to the USB port on the rear panel of the Liebert ® GXT3 ™ ([...]
-
Page 25
Controls and Indica tors 19 3.0 C ONTROLS AND I NDICATORS The operation and displ ay panel, shown in Figure 18 , is on the front panel of the Liebert ® GX T3 ™ (see Figures 1 and 2 ). Figure 18 Operation and display p anel 3.1 Control Buttons The operation an d display panel ha s two control bu ttons: On/Alarm Silence/Manua l Battery Test and St[...]
-
Page 26
Controls and Indica tors 20 3.2 Indicators The operation and display panel has seven indicators (see Figure 18 ). The indi cators can be divide d into two groups according to the applications: level i ndicators and UPS status indicators. 3.2.1 Level Indicators Battery Level Indicators The battery level indicator is compos ed of five sets of LED bar[...]
-
Page 27
Controls and Indica tors 21 3.2.2 UPS St atus Indicators UPS status is indicated by five symbols: fault indicator, AC input indica tor, battery indicator, inverter indicator and bypass indicator. Table 5 shows the symbols and their meaning. T able 5 UPS st atus indicators UPS Status Indicator Icon Color Description Fault Indicator Red On if the UPS[...]
-
Page 28
Operation 22 4.0 O PERATION This section describes checks to be made before starting the UPS, how to start the UPS, manual battery test, manual bypass, shutting down the UP S and disconnecting the utility power from the UPS. 4.1 St artup Checklist for the Liebert GXT3 Before starting the UPS, perform these checks: ___ 1. Check that the input plugs [...]
-
Page 29
Operation 23 4.5 Shut Down the Liebert ® GXT3 ™ 1. Transfer the UPS to manual bypass by pressing the Standby/Manual Bypass button and holding it for about 2 seconds. If manual bypass is not avai lable, disregard the first step. 2. Press the Standby/Manual By pass bu tton twice within four second s to shut down the UPS. The UPS will shut down abo[...]
-
Page 30
Communication 24 5.0 C OMMUNICATION This section describes UPS communication over the three types of communicati on connections on the rear of the Liebert ® GXT3 ™ : • Liebert IntelliSl ot ® port • USB port (standard B-type) • Terminal Block Communication 5.1 Liebert IntelliSlot Communication Car ds The Liebert IntelliSlot port accepts th[...]
-
Page 31
Communication 25 5.2 USB Port Communication The standard B-type USB port is used to connect the UPS and network server or other compute r system using Lieb ert ® MultiLink ® . Configuration prog ram ca n be accessed through the communication port. 5.2.1 Configuration Program Accessing the Configuration Program via US B is a new feature of the Lie[...]
-
Page 32
Communication 26 5.3 T erminal Block Communication The Terminal Block includes eight pins, as shown in Figure 21 . Figure 21 T erminal block communication pin layout 5.3.1 Any-Mode Shut down The purpose of Any Mode Shutdown i s to shut do wn the UPS output by tu rning Off the rectifier, inverter and bypa ss so that there is no p ower to the load s.[...]
-
Page 33
Communication 27 5.3.2 Battery Mode Shut down Battery Mode Shutdown permits shuttin g down the U PS by turning Off the rectifier, inverter and bypass so that there is no power to the load when the UPS is On Battery. Battery Mode Shutdown can be performed locally or remotely: • Local Any Mode Shutdown can be performed by shorting Pin 3 a nd Pin 4 [...]
-
Page 34
Maintenance 28 6.0 M AINTENANCE This section describes replaci ng the internal bat te ry pack, precaution s, checking the Li ebert ® GXT3’s status and checking U PS functions. 6.1 Replacing the Internal Battery Pack The Liebert ® GXT3 ™ is designed to allow the use r to replace the interna l battery pa ck safely. Re fer to Table 7 for interna[...]
-
Page 35
Maintenance 29 Figure 22 Removing the front bezel cover a nd battery door 4. Ge ntly pull the battery wire ou t and disconnect th e battery plug a nd battery rece ptacle, as shown in Figure 23 . Figure 23 Disconnecting the battery plug and battery recept acle (front view) 5. Grasp the battery handle, and pu ll the internal battery pack out o f the [...]
-
Page 36
Maintenance 30 6.2 Battery Charging The batteries are valve-regulated, nonspillabl e, lead acid and should be kept charged to attain their design life. The Liebert ® GXT3 ™ charges the batteries continuously wh en it is connected to the utility input power. If the Liebert GXT3 will be stored for a long ti me, Emerson recommends connecting the UP[...]
-
Page 37
Trou bleshooting 31 7.0 T ROUBLESHOOTING This section indicate s various UP S symptoms a user may encounter and troubleshooting steps in the event the UPS develops a problem. Use the follow ing information to determ ine whether external factors caused the problem and how to remedy the sit uation. 7.1 UPS Symptoms The following symptoms indicate the[...]
-
Page 38
Trou bleshooting 32 7.1.2 Audible Alarm An audible alarm will be used in conjunction with the visual indicators to indicate to the user a change in UPS operating status. The audible alarm wil l enunciate as given in Table 9 . 7.2 T roubleshooting In the event of an issue with the UPS, refer to Table 1 0 to determine the caus e and solution. If the [...]
-
Page 39
Trou bleshooting 33 When reporting a UPS issue to Em erson, include the UPS model and serial number. These are on the top panel of the Liebert ® GXT3 ™ . Fault and Bypass indi cators and diagnostic B indicator are illuminated UPS internal DC bus overvoltage UPS requires service. Contact Emerson Channel Support. Fault and Bypass indi cators and d[...]
-
Page 40
Battery Cabinet 34 8.0 B ATTERY C ABINET Optional battery ca binets are available for the Liebert ® GXT3 ™ . The battery connectors and input breaker are on the battery cabinet’s rear pan el, as shown in Figure 26 . For battery cabinet specifications, ref er to Table 13 . The Liebert GXT3 ma y be equipped with a maximum of four extension batte[...]
-
Page 41
Specifications 35 9.0 S PECIFICATIONS T able 1 1 S pecifications of GXT3-500RT1 20 - GXT3-1000RT120 and GXT3-1000M T120 UPS Parameters Product Model GXT3-500RT120 (500VA/450W) GXT3-700RT120 (700VA/630W) GXT3-1000RT120 (1000VA/900W) GXT3-1000MT120 (1000VA/900W) Dimensions, D × W × H, in. (mm) Unit 19.7 x 16.9 x 3.4 (497 × 430 × 85) 15.4 x 6.9 x [...]
-
Page 42
Specifications 36 T able 12 Specifica tions of GXT3-1500RT 120 - GXT3-3000RT120 and GXT3-3000RT208 UPS Parameters Product Model GXT3-1500RT120 (1500VA/1350W) GXT3-2000RT120 (2000VA/1800W) GXT3-3000RT120 (3000VA/2700W) GXT3-3000RT208 (3000VA/2700W) Dimensions, D × W × H, in. (mm) Unit 19.7 x 16.9 x 3.4 (497 × 43 0 × 85) 23.7 x 16.9 x 3.4 (602 ×[...]
-
Page 43
Specifications 37 T able 13 Battery cabinet specifications Parameter Model Number GXT3-48VBATT GXT3-72VBATT Used w/UPS Model GXT3-500RT120,GXT3-700RT12 0 GXT3-1000RT120,GXT3-1500RT120, GXT3-2000RT120 GXT3-3000RT120 GXT3-3000RT208 Dimensions, D × W × H, in (mm) Unit 19.7 x 16.9 x 3.3 (497 × 430 × 85) 23.7 x 16.9 x 3.3 (602 × 430 × 85) Shipping[...]
-
Page 44
Specifications 38 T able 15 Battery run time s Number of Batteries/Cabinets Load Percent of Capacity 120VAC RT Models 208 VAC RT Model 500VA 700VA 1000VA 1500VA 2000VA 3000VA 3000VA Internal Battery 10% 128 105 90 77 77 74 77 2 0 % 8 2 6 1 3 73 53 33 6 3 7 3 0 % 4 1 3 7 3 02 32 12 1 2 1 4 0 % 3 8 3 2 2 31 61 51 5 1 5 5 0 % 3 4 2 7 1 71 11 11 1 1 1 [...]
-
Page 45
Specifications 39 9.1 Product W arranty Registration To register for warranty protection, visit the Quick Links section of the Liebert ® Web site at: http://www.liebert.com Click on Product Warranty Registration and fill in the form. If you have any questions, cont act Emerson Channel Support at: North America: 800-222 -5877 Outside North America:[...]
-
Page 46
Specifications 40[...]
-
Page 47
[...]
-
Page 48
Ensuring The Hi gh Av ailabilit y Of Mission-Critic al Dat a And Applic ations. Emerson Net work P ower , a business of Emer son (NYSE:EMR), is the global leader in enabling Business-Critic al Continuity ™ from grid to chip f or telecommunication networks, data centers, health care and industrial facilities. Emerson Network Po wer provides inno v[...]