Emerson 210-2000 manual

1
2
3
4

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson 210-2000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson 210-2000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson 210-2000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson 210-2000 should contain:
- informations concerning technical data of Emerson 210-2000
- name of the manufacturer and a year of construction of the Emerson 210-2000 item
- rules of operation, control and maintenance of the Emerson 210-2000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson 210-2000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson 210-2000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson 210-2000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson 210-2000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Carbon Dioxide Sensor Product Information Sheet 210-2000 Overview CPC’s CO 2 sensor (P/N 210 -2000) is a non-dispers ive infrared analyzer designed for measuring environm ental CO 2 conc entratio n in ventila tion systems and indoor spaces. Its measurement range of 0-2000 or 0-5000 ppm covers th e range required to monitor compliance wi th ASHRAE[...]

  • Page 2

    Carbon Dioxide Sensor Product Information Sheet 210-2000 Wiring The mounting plate has two sets of th ree-terminal connectors. T he connecto r on the left side of th e mounting plate is wher e sensor power and the signa l- to-I/O-board connection is made. The connector on the right sid e is where con nection to th e on-board relay is made. Power Wi[...]

  • Page 3

    Carbon Dioxide Sensor Product Information Sheet 210-2000 Setting the Volts/Amps Switch The front of the circu it board has a switch that controls whether the analog outpu t sends a signal as voltage (V) or mi lliamps (mA). To work with CPC I/ O boards, this switch should be set to voltage (the DOWN position). Verify th is switch is in the DOWN posi[...]

  • Page 4

    Carbon Dioxide Sensor Product Information Sheet 210-2000 Span The Span parameter determines whether you want to measure concen trations between 0-2000 ppm or 0 - 5000 ppm. If set to 2000 ppm, the sen sor’s analog output signal will be scaled proper ly so that the highest output voltag e corresponds to 2000 ppm. Likewise, if set to 5000 ppm, the h[...]