Emerson 3U MP2-220N manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson 3U MP2-220N, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson 3U MP2-220N one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson 3U MP2-220N. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson 3U MP2-220N should contain:
- informations concerning technical data of Emerson 3U MP2-220N
- name of the manufacturer and a year of construction of the Emerson 3U MP2-220N item
- rules of operation, control and maintenance of the Emerson 3U MP2-220N item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson 3U MP2-220N alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson 3U MP2-220N, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson 3U MP2-220N.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson 3U MP2-220N item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    P OWER A VAILABILITY 3U MP2-220N POD™ U SER M ANUAL Power Output Distribution 208 V olt 16 Amp[...]

  • Page 2

    [...]

  • Page 3

    i T ABLE OF CONTENTS I MPORT ANT S AFETY I NSTRUC TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.0 I NTRODUCTI ON AND S YST EM D ESCRIPTION . . . . . . . .[...]

  • Page 4

    ii[...]

  • Page 5

    1 I MPORT ANT S AFE TY I NSTRUCTIONS SA VE THESE INSTRUCTIONS This manual contains importa nt instructions that should be followed during i nstallation and opera- tion of the MP2-22 0N POD™. This product is de signed for comme rcial / industrial use only, with Liebert UPS systems. It is not intended for use with life support and other designated [...]

  • Page 6

    2 G LOSSARY OF S YMBOLS Equipment grounding conducto r Bonded to ground Electric phase Indicates AC input Indicates AC output Indicates caution followed by important instructions[...]

  • Page 7

    Introduction and System Descriptio n 3 1.0 I NTRODUCTION AND S YSTEM D ESCRIPTION Congratulations on your choice of the Liebert MP2-220N P OD™ (3U POD). The 3U PO D provides maintenance bypass capability as well as power output distri bution. The 3U POD can be used on UPSs in the rack mount or tower configuration. The 3U POD provides an isolated [...]

  • Page 8

    Rack Mount Installation 4 2.0 R ACK M OUNT I NST ALLATION 1. Rack mount installation of the 3U POD is possibl e with the use of the rack mounting brackets (shipped with the 3U POD). See Figure 4 . 2. The rack mounting brackets allow you to rack mount the 3U POD in a 19" enclosure (23" to 19" rack adapters would have to be purchased s[...]

  • Page 9

    Installation and Electrical Connections 5 3.0 I NST ALLATION AND E LECTRICAL C ONNECTIONS Unpack the 3U POD carefully, noting the packing me thod. Retain the box an d packing material for possible future shipments. Visually inspect the 3U POD for freight dam age. Repo rt damage to the carrier and your local dealer, Liebert representative or the Lie[...]

  • Page 10

    Alternate Hardwire Installation 6 4.0 A LTERNATE H ARDWIRE I NST ALLATION 4.1 Electrical Inst alla tion Considerations The utility inp ut supply cable must be con nected to the unit via a wall-mounted circuit breaker. The UPS output port must also be protected with a circu it breaker connected to the load, rated to carry the input current, and be c[...]

  • Page 11

    Alternate Hardwire Installation 7 4.3 Conversion From Cord-Recept acle to Hardwire Two wiring access panels on the front of the 3U POD allow access to the wiring compartments. Each access door is retained usin g four Phil lips head screws. 1. Remove the eight Ph illips head screws from the wiring acce ss panels on the front of the unit. Save the sc[...]

  • Page 12

    Indicator La mps 8 5.0 I NDICATOR L AM P S 5.1 UTILITY Indicator Lamp This amber lam p is illuminate d when utility power is pres ent (see Figure 5 ). It signals that you may transfer the loads to maintenance bypass (UTILITY mode) operation via the rotary switch. During a utility power outage, this lamp will be off and the UPS will supply battery b[...]

  • Page 13

    Operation 9 6.0 O PERATION 6.1 T ransfer to Maintenance Bypass To transfer to maintenance bypass (uti lity) from UPS, use the following steps: 1. Ensure the UTILITY lamp (amber) is illu minate d. If the lamp is not illuminated, refer to 7.0 - Troubleshooting . 2. Transfer the rotary switch from UPS to UTILIT Y, provided the UTILITY lamp is illumina[...]

  • Page 14

    Trou bleshooting 10 7.0 T ROUBLESHO OTING Problem Cause Solution UTILIT Y lamp (amber) not Illuminated. Utility not present. Call qualified serv ice personnel to restore power. Utility Branch Circuit Breaker may be open. Verify that the branch circuit breaker is closed. 3U POD input power not connecte d to UTILITY. Refer to the 3U POD installation [...]

  • Page 15

    Specifications 11 8.0 S PECIFICATIONS This 3U POD is intended fo r use with a UPS me eting all the following requirements: • UPS input cord is compatible wi th the rating an d type of receptacle on the 3U POD labeled “CON- NECT UPS LINE CORD HERE.” • UPS output receptacle is co mpatible with the 3U POD input power connector labeled “UPS.?[...]

  • Page 16

    Specifications 12[...]

  • Page 17

    [...]

  • Page 18

    The Comp any Behind the Products With over a million installations around th e globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a complete range of support and protection systems fo r sensitive electronics: • Env ironmental systems—close-control air conditioning from 1 to 60 to[...]