Emerson CF144ORB00 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF144ORB00, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF144ORB00 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF144ORB00. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF144ORB00 should contain:
- informations concerning technical data of Emerson CF144ORB00
- name of the manufacturer and a year of construction of the Emerson CF144ORB00 item
- rules of operation, control and maintenance of the Emerson CF144ORB00 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF144ORB00 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF144ORB00, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF144ORB00.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF144ORB00 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part No. F40BP74070000 Form No. BP7407 UL Model No.: CF144 & CF152 READ AND SA VE THESE INSTRUCTIONS CUR V A SKY ™ 44” & 52” Damp & W et Loca tion Snugger Ceiling F an Owner's Manual CF144BS00 Br ushed Steel CF144CRM00 Chrome 44” Model Number s for Damp Loca tions CF144WW00 Appliance W hite CF144ORB00 Oil Rubbed Bronze 44?[...]

  • Page 2

    WARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’ s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidental[...]

  • Page 3

    3 THE F AN MODELS CF144BS, CF144CRM, CF152BS & CF152CRM ARE SUIT ABLE FOR DAMP LOCA TIONS SUCH AS COVERED PORCHES, COVERED P A TIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. THE F AN MODELS CF144WW , CF144ORB, CF152WW & CF152ORB ARE SUIT ABLE FOR WET LOCA TIONS SUCH AS PORCHES, P A TIOS, AND DECKS. This Manual is Designed to M[...]

  • Page 4

    4 2. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. B. CEILING TRIM RING D. F AN BLADES (3) G. GLASS SHADE A. F AN MOTOR ASSEMBL Y H. NO-LIGHT COVER PLA TE E. LOWER HOUSING K. 50W MINI CANDELABRA HALOGEN BULBS L. LOOSE P ARTS BAG J. 6-SPEED HANDHELD TRANSMITTER F . LIGHT KIT PLA TE [...]

  • Page 5

    5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. General Y our Emerson ceiling fan comes supplied with a Fan/Light Remote Control which consists of a receiver mounted inside the ceiling cov[...]

  • Page 6

    CEILING FLOOR AT LEAST 7' Figure 5 6 UL Model No.: CF144 & CF152 9. T uck the wires and connectors into the fan housing. Position the light kit plate into the fan housing by placing the cut out notches over the fan housing dimples (Figure 4). 10. Attach the light kit plate assembly to the lower housing using two key slot holes (Figure 4). [...]

  • Page 7

    7 UL Model No.: CF144 & CF152 2. Pull the electrical supply black, white and ground wires through the center opening of the ceiling mounting plate before securing the plate to the outlet box (Figure 6). 3. Position the ceiling mounting plate onto the outlet box and secure using the two outlet box screws, supplied with outlet box (Figure 6). Fig[...]

  • Page 8

    UL Model No.: CF144 & CF152 3. After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other inside of the outlet box. T o avoid possible fire or shock, make sure that the electrical wires are completely ins[...]

  • Page 9

    1. Screw in two 50-watt (maximum) halogen mini candelabra base bulbs in the light kit plate sockets (Figure 13). 50-WA TT (maximum) HALOGEN MINI CANDELABRA BASE BULBS (2) LIGHT KIT PLA TE SOCKETS (2) Figure 13 2. Place the glass shade into the opening in the fan motor housing assembly , aligning the three flat areas on the top edge of the glass wit[...]

  • Page 10

    10 UL Model No.: CF144 & CF152 General Y our Emerson Ceiling Fan/Light Remote Control consists of hand-held transmitter and a receiver which is mounted under the fan ceiling cover . The remote control is designed to separately control your ceiling fan speed and light intensity . The remote control transmitter is powered by two AAA alkaline batt[...]

  • Page 11

    11 UL Model No.: CF144 & CF152 Setting Operating F r equency of R emote Control 1. Slide the five switch levers in the remote control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 2. When power is restored, push and hold the fan OFF button ( ) for 3 to 5 seconds to[...]

  • Page 12

    UL Model No.: CF144 & CF152 12 INSTRUCTION TO THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.[...]

  • Page 13

    UL Model No.: CF144 & CF152 13 Fan/Light Fails to Operate • Check that the speed switch on the fan is set to HIGH ( .... ) speed. • Check that the light switch is on. • Check that the battery is good (red indicator light should light when any button is pressed). • Check that the receiver is wired properly . • Check that code switches [...]

  • Page 14

    14 UL Model No.: CF144 & CF152 Damp Part Numbers Wet Part Numbers Key Model No. Model No. Model No. Model No. Model No. Model No. Model No. Model No. No. Description CF144BS00 CF152BS00 CF144CRM00 CF152CRM00 CF144WW00 CF152WW00 CF144ORB00 CF152ORB00 1 Ceiling Mounting Plate 763987 763987 763987 763987 763987 763987 763987 763987 2 Ceiling T rim[...]

  • Page 15

    15 UL Model No.: CF144 & CF152 R epair Par ts 2 3 15 8 - 52" 9 - 44" 1 14 4 5 6 5 10 16 13 17 12 11 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL WA YS GIVE THE FOLLOWING INFORMA TION: The model number of your Fan will be found on a label atta[...]

  • Page 16

    LIMITED WARRANTY What The W ar ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor , this warranty will l[...]