A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF1WB01, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF1WB01 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson CF1WB01. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson CF1WB01 should contain:
- informations concerning technical data of Emerson CF1WB01
- name of the manufacturer and a year of construction of the Emerson CF1WB01 item
- rules of operation, control and maintenance of the Emerson CF1WB01 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF1WB01 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF1WB01, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF1WB01.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF1WB01 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
READ AND SA VE THESE INSTRUCTIONS Model No. CF1AB01 CF1WB01 CF1PW01 CORNERSTONE ™ Series Ceiling Fan Owner's Manual Part No. F40BP72500002 Form No. BP7250-2 Max. Weight: 27.0 Lbs. With Blades ® DATE CODE: The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a sa[...]
-
Page 2
This Manual Is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan T ools Needed for Assembly One Phillips head screwdriver One stepladder Five wire connectors (supplied) One wire stripper MA TERIALS Wiring outlet box and box connectors must be of type required by the local code. The minimum[...]
-
Page 3
1. Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following: a. Fan motor and housing assembly b. One motor cover c. One ceiling cover d. One ceiling cover trim e. Four blade flanges (14°) f. Two blade flanges (20°) g. One hanger ball/downrod assembly h. One 18” do[...]
-
Page 4
4 1. Remove the fan motor and housing assembly from styrofoam packaging and position it so that the top of the motor is facing you. 2. Remove the hanger ball from the downrod by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the [...]
-
Page 5
5 7. If you have installed the 18” downrod, install the downrod trim and decorative bulb as follows (Figure 5). Slide the decorative trim (grommet-end first) over the downrod and seat the grommet firmly against the motor cover. Then slide the decorative bulb (oriented as shown) over the downrod, being certain that the downrod trim seats in the bo[...]
-
Page 6
How to Hang Y our Ceiling Fan 1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 13). 2. Carefully lift the fan and seat the hanger ball/ downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 14). Be sure the groove in the ball is lined up with tab on [...]
-
Page 7
7 OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y Figure 3 NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY . Figure 14 To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and the hanger bracket. W ARNING ! How to Wir e Y our Ceiling Fan If you feel that you do not have enough e[...]
-
Page 8
Using Y our Ceiling Fan 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the 4-position speed control pull chain switch (Figure 17). The operating sequence is as follows: 3. If airflow is desired in opposite direction, turn your fan off and wait [...]
-
Page 9
T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch switch wire connections in [...]
-
Page 10
10 8 33 24 12 36 10 5 4 35 25 26 15 18 19 9 21 23 24 11 40 7 38 28 29 31 30 32 22 14 13 37 39 34 1 2 16 17 3 18 6 20 19 27 Repair Par ts Before discarding packaging material, be certain all parts have been removed. How to Or der Repair Par ts WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION •[...]
-
Page 11
Repair Par ts Listing Part Numbers Key Model No. Model No. Model No. N o . Description CF1AB01 CF1WB01 CF1PW01 — Hanger Pack, Containing: 761655-3 761655-20 761655-22 1 Bracket, Hanger (1) — — — 2 Hanger Ball Assembly (1) — — — 3 Downrod (1) — — — 6 Ceiling Canopy 761620-3 761620-26 761620-30 7 Trim, Ceiling Cover 762077 762077-[...]
-
Page 12
Printed in Taiwan 04/03 Part No. F40BP72500002 Form No BP7250-2 LIMITED W ARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of [...]