Go to page of
Similar user manuals
-
Fan
Emerson CF704SPB02
8 pages 0.12 mb -
Fan
Emerson CF704SORB03
8 pages 0.21 mb -
Fan
Emerson CF820PW00
16 pages 0.46 mb -
Fan
Emerson CF704SAW02
8 pages 0.12 mb -
Fan
Emerson CF704SPB03
8 pages 0.21 mb -
Fan
Emerson KF240PRZ00
20 pages 0.48 mb -
Fan
Emerson CF3300ORH
16 pages 0.35 mb -
Fan
Emerson CF670CK00
8 pages 0.22 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF244ORB00, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF244ORB00 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson CF244ORB00. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson CF244ORB00 should contain:
- informations concerning technical data of Emerson CF244ORB00
- name of the manufacturer and a year of construction of the Emerson CF244ORB00 item
- rules of operation, control and maintenance of the Emerson CF244ORB00 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF244ORB00 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF244ORB00, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF244ORB00.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF244ORB00 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Part No. F40BP74080000 Form No. BP7408 UL Model No.: CF244 & CF252 READ AND SA VE THESE INSTRUCTIONS Net Weight: 16.7 Lbs. Net Weight: 17.6 Lbs. 44” & 52” Damp & W et Location Ceiling F an Owner's Manual CF244BS00 Br ushed Steel CF244CRM00 Chrome 44” Model Number s for Damp Loca tions CF244WW00 Appliance W hite CF244ORB00 Oil[...]
-
Page 2
WARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’ s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidental[...]
-
Page 3
3 THE F AN MODELS CF244BS, CF244CRM, CF252BS & CF252CRM ARE SUIT ABLE FOR DAMP LOCA TIONS SUCH AS COVERED PORCHES, COVERED P A TIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. THE F AN MODELS CF244WW , CF244ORB, CF252WW & CF252ORB ARE SUIT ABLE FOR WET LOCA TIONS SUCH AS PORCHES, P A TIOS, AND DECKS. This Manual is Designed to M[...]
-
Page 4
4 2. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. D. FAN BLADES (3) A. FAN MOTOR ASSEMBL Y L. LOOSE PAR TS BAG B. CEILING COVER F . LIGHT KIT PLA TE C. COUPLER COVER K. 50W MINI CANDELABRA HALOGEN BULBS E. LOWER HOUSING I. 6-SPEED ELECTRONIC RECEIVER G. GLASS SHADE H. NO-LIGHT COV[...]
-
Page 5
5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. General Y our Emerson ceiling fan comes supplied with a Fan/Light Remote Control which consists of a receiver mounted inside the ceiling cov[...]
-
Page 6
6 UL Model No.: CF244 & CF252 11 . Carefully turn the partially assembled ceiling fan right side up and place the fan securely into the packing styrofoam in preparation for final assembly . 12. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 5). Remove the pin from the dow[...]
-
Page 7
7 UL Model No.: CF244 & CF252 SETSCREW CLEVIS PIN MOTOR COUPLING DOWNROD HAIRPIN CLIP DOWNROD HAIRPIN CLIP MOTOR COUPLING SETSCREW (2) CLEVIS PIN Figure 6 HAIRPIN CLIP CLEVIS PIN MOTOR COUPLING COUPLER COVER SETSCREW (2) Figure 7 14. While pulling up on the downrod, securely tighten the two setscrews in the motor coupling (Figure 7). NOTE: The [...]
-
Page 8
T urning off wall switch is not sufficient. T o avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. ! WARNING 2. Securely attach the hanger[...]
-
Page 9
T o avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket. ! WARNING NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY . OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y 1-1/4" THREADED STUD (2) Figure 11 9 UL Model No.: CF244 & CF252 How to Wir e Y our Ceil[...]
-
Page 10
UL Model No.: CF244 & CF252 3. After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other inside of the outlet box. 4. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger [...]
-
Page 11
1. Screw in two 50-watt (maximum) halogen mini candelabra base bulbs in the light kit plate sockets (Figure 15). 50-WA TT (maximum) HALOGEN MINI CANDELABRA BASE BULBS (2) LIGHT KIT PLA TE SOCKETS (2) Figure 15 2. Place the glass shade into the opening in the fan motor housing assembly , aligning the three flat areas on the top edge of the glass wit[...]
-
Page 12
12 UL Model No.: CF244 & CF252 General Y our Emerson Ceiling Fan/Light Remote Control consists of hand-held transmitter and a receiver which is mounted under the fan ceiling cover . The remote control is designed to separately control your ceiling fan speed and light intensity . The remote control transmitter is powered by two AAA alkaline batt[...]
-
Page 13
13 UL Model No.: CF244 & CF252 Setting Operating F r equency of R emote Control 1. Slide the five switch levers in the remote control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 2. When power is restored, push and hold the fan OFF button ( ) for 3 to 5 seconds to[...]
-
Page 14
UL Model No.: CF244 & CF252 14 Fan/Light Fails to Operate • Check that the speed switch on the fan is set to HIGH ( .... ) speed. • Check that the light switch is on. • Check that the battery is good (red indicator light should light when any button is pressed). • Check that the receiver is wired properly . • Check that code switches [...]
-
Page 15
UL Model No.: CF244 & CF252 15 Ceiling F an T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan. to fa[...]
-
Page 16
16 UL Model No.: CF244 & CF252 Damp Part Numbers Wet Part Numbers Key Model No. Model No. Model No. Model No. Model No. Model No. Model No. Model No. No. Description CF244BS00 CF252BS00 CF244CRM00 CF252CRM00 CF244WW00 CF252WW00 CF244ORB00 CF252ORB00 * Hanger Pack Consisting of: 761655-17 761655-17 761655-88 761655-88 761655-14 761655-14 761655-[...]
-
Page 17
17 UL Model No.: CF244 & CF252 R epair Par ts 7 16 12 15 23 22 21 14 13 10 - 52" 11- 44" 1 20 9 18 19 5 8 6 17 3 2 4 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL WA YS GIVE THE FOLLOWING INFORMA TION: The model number of your Fan will be foun[...]
-
Page 18
18 UL Model No.: CF244 & CF252 INSTRUCTION TO THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.[...]
-
Page 19
19 UL Model No.: CF244 & CF252 LIMITED WARRANTY What The W ar ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies [...]
-
Page 20
UL Model No.: CF244 & CF252 Part No. F40BP74080000 Printed in China 01/10 Form No. BP7408 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W . Florissant • St. Louis, MO 63136 BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 20[...]