A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF3600ORH, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF3600ORH one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF3600ORH. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF3600ORH should contain:
- informations concerning technical data of Emerson CF3600ORH
- name of the manufacturer and a year of construction of the Emerson CF3600ORH item
- rules of operation, control and maintenance of the Emerson CF3600ORH item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF3600ORH alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF3600ORH, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF3600ORH.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF3600ORH item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part No. F40BP73840000 Form No. BP7384 Model No.: CF3600 READ AND SA VE THESE INSTRUCTIONS Net Weight: 15.9 Lbs. CAMDEN ™ 52” Damp Loca tion Ceiling F an Owner's Manual CF3600AP Antique P ewter CF3600ORH Oil R ub bed Br onze with Highlights Model Number s BP7384 Camden, CF3600 2/18/09 2:57 PM Page 1[...]

  • Page 2

    WARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’ s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidental[...]

  • Page 3

    3 THIS F AN IS SUIT ABLE FOR DAMP LOCA TIONS SUCH AS COVERED PORCHES, COVERED P A TIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing. Call T oll-Free: 1-80[...]

  • Page 4

    4 2. Remove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly . 3. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. 4. Position the fan motor assembly , with the motor hub facing up, carefully on the styrofoam for blade assembly . A.[...]

  • Page 5

    5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. T o reduce the risk of fire, electric shock, or personal injury , mount fan to outlet box marked “Acceptable for Fan Support”, and use s[...]

  • Page 6

    8. Carefully turn partially assembled fan over and place on top of the styrofoam, resting on switch cover assembly . 6 9. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 4). Remove the clevis pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for[...]

  • Page 7

    F AN MOTOR ASSEMBL Y DOWNROD MOTOR COVER #8-32 x 1/4" P AN HEAD SCREW (4) Figure 6 MOTOR COVER COUPLING COVER DOWNROD GROMMET CEILING COVER Figure 7 14. Make sure the grommet is properly installed in the coupling cover then slide the coupling cover over the downrod until it rests on the motor housing cover . Place the ceiling cover over the do[...]

  • Page 8

    1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 10). How to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). ! WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only[...]

  • Page 9

    9 2. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 1 1). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 10). Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until brack[...]

  • Page 10

    3. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 12). 4. Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 13). 5. Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and insta[...]

  • Page 11

    11 Model No.: CF3600 1. Downrod Extension Kits (see store or catalog). 2. Blades (see store or catalog). Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! WARNING The use of any other control not specifically approved for this fan could result in fire, shock[...]

  • Page 12

    12 R epair Par ts 8 6 5 1 4 3 2 7 19 9 20 15 18 BLADE SETS SOLD SEP ARATEL Y 11 22 23 12 13 24 14 25 16 21 17 26 10 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL WA YS GIVE THE FOLLOWING INFORMA TION: The model number of your Fan will be found on a label at[...]

  • Page 13

    13 Part Numbers Key Model No. Model No. N o . Description CF3600AP00 CF3600ORH00 * Hanger Pack, Consisting of: 761655-80 761655-65 1 Hanger Bracket Assembly (1) — — 2 Hanger Ball (1) — — 3 Downrod (1) — — * Parts Bag, Containing: 763862 763862 4 Stud, Threaded, #8-32 x 1-1/4” (2) — — 5 Lockwasher , External T ooth #8-32 (2) — ?[...]

  • Page 14

    14 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan. to fan. 3. Fan/Light W all Control is OFF. 3. T ur[...]

  • Page 15

    15 LIMITED WARRANTY What The W ar ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor , this warranty wil[...]

  • Page 16

    Part No. F40BP73840000 Printed in China 01/09 Form No. BP7384 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W . Florissant • St. Louis, MO 63136 Model No.: CF3600 BP7384 Camden, CF3600 2/18/09 2:57 PM Page 16[...]