Emerson CF552GBZ00 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF552GBZ00, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF552GBZ00 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF552GBZ00. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF552GBZ00 should contain:
- informations concerning technical data of Emerson CF552GBZ00
- name of the manufacturer and a year of construction of the Emerson CF552GBZ00 item
- rules of operation, control and maintenance of the Emerson CF552GBZ00 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF552GBZ00 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF552GBZ00, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF552GBZ00.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF552GBZ00 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part No. F40BP73930001 Form No. BP7393-1 U.L. Model No.: CF552 READ AND SA VE THESE INSTRUCTIONS 52” Ceiling F an W et Loca tion Owner's Manual CF552AW00 - Summer W hite CF552GBZ00 - Gilded Br onze CF552GES00 - Golden Espr esso CF552ORB00 - Oil R ubbed Br onze CF552WB00 - W eathered Br onze Model Number s CARRERA VERAND A ™ Net W eight: 21[...]

  • Page 2

    WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. [...]

  • Page 3

    1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing assembly c. One ceiling cover d. Five blade flanges e. One hanger ball/4.5” downrod assembly f. One hanger bracket g. One coupling cover h. Five fan blades i. [...]

  • Page 4

    4 1. One by one unscrew each screw and discard screw and shipping retainer (Figure 1). BLADE FLANGE M5 x 6mm WASHER HEAD BLADE SCREW (3 per blade/flange) FAN BLADE To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between [...]

  • Page 5

    ROT A TE SWITCH HOUSING ADAPTER CLOCKWISE TO ENGAGE TWO KEYHOLE SCREWS TIGHTEN TWO M4 x 10mm SERRA TED P AN HEAD SCREWS REINST ALL ONE M4 x 10mm SERRA TED PAN HEAD SCREW 5 Figure 4 SWITCH HOUSING SWITCH HOUSING ASSEMBL Y MOTOR CONNECTOR SWITCH HOUSING CONNECTOR Figure 5 4. The blade flanges have an interlocking feature that must be fully engaged be[...]

  • Page 6

    CEILING COVER HANGER BALL PIN SETSCREW Figure 10 It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. WARNING ! 16. The fan comes with blue, black and white leads that are 80” long. Before instal[...]

  • Page 7

    7 Ho w to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 11). A T LEAST 7' CEILING FLOOR Figure 11 WARNING ! The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”. WARNING ! [...]

  • Page 8

    8 U.L. Model No.: CF552 If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green c[...]

  • Page 9

    1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward. If airflow is desired in opposite direction, turn your fan[...]

  • Page 10

    10 WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, 2. Check line wire[...]

  • Page 11

    R epair P ar ts Listing Model Numbers Key N o . Description CF552AW00 CF552GBZ00 CF552GES00 CF552ORB00 CF552WB00 * Hanger Ball Assembly, 761655-21 761655-77 761655-35 761655-32 761655-86 Consisting of: 1 Hanger Bracket — — — — — 2 Hanger Ball — — — — — 3 Downrod (4.5”) — — — — — * Parts Bag Containing: 763913-3 76391[...]

  • Page 12

    U.L. Model No.: CF552 Part No. F40BP73930001 Printed in China 07/09 Form No. BP7393-1 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in w[...]