Go to page of
Similar user manuals
-
Fan
Emerson CF770AW01
8 pages 0.17 mb -
Fan
Emerson CF2455ORB00
16 pages 0.28 mb -
Fan
Emerson CF1WB01
12 pages 0.33 mb -
Fan
Emerson CF772ORB00
16 pages 0.29 mb -
Fan
Emerson CF1AB01
12 pages 0.33 mb -
Fan
Emerson CF710PB01
12 pages 0.26 mb -
Fan
Emerson CF670OB00
8 pages 0.22 mb -
Fan
Emerson CF4600GLZ00
20 pages 0.32 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF775AW02, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF775AW02 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson CF775AW02. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson CF775AW02 should contain:
- informations concerning technical data of Emerson CF775AW02
- name of the manufacturer and a year of construction of the Emerson CF775AW02 item
- rules of operation, control and maintenance of the Emerson CF775AW02 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF775AW02 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF775AW02, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF775AW02.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF775AW02 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Part No. F40BP73620001 Form No. BP7362-1 U.L. Model No.: CF775-2 READ AND SA VE THESE INSTRUCTIONS Model No. CF775AW02 CF775BS02 CF775ORB02 SP ANISH B A Y ™ Net Weight: 23.6 Lbs. Ceiling F an Owner's Manual LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceili[...]
-
Page 2
2 WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on acci[...]
-
Page 3
1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing assembly c. Five fan blades d. One ceiling cover e. Five blade flanges f. One hanger ball/downrod assembly g. One hanger bracket h. One coupling cover i. One lig[...]
-
Page 4
1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5. 2. Loosen the two setscrews in the motor coupling and separate, untwist and unkink the three 80” [...]
-
Page 5
5 8. Turn the fan assembly upside down in preparation for mounting the fan blade assemblies. NOTE: Take care not to scratch fan housing when installing blades. BLADE FLANGE FAN BLADE M5 x 6 SLOTTED PHILLIPS WASHER HEAD BLADE SCREW (3) BLADE WASHER (3) Figure 5 PREASSEMBLED M6 x 14 FLANGE SCREWS (2) (INST ALL THROUGH SLOT IN SWITCH HOUSING PLA TE) B[...]
-
Page 6
6. Remove the three switch housing screws from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three screws (Figure 10). 7. Install three 60-watt (maximum) candelabra base li[...]
-
Page 7
7 1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 13.) Ho w to Hang Y our Ceiling F an A T LEAST 7' CEILING FLOOR OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y NOTE: CEILING COVER, SUPPL Y WIRES AND FAN WIRES OMITTED FOR CLARITY . Figure 12 Figure 14 2. Carefully lif[...]
-
Page 8
5. Secure the ceiling cover in place by sliding lock- washers over the threaded studs and installing the two knurled knobs (supplied). (Figure 16.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from t[...]
-
Page 9
9 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned to the “left” circulate air downward. If airflow is desired in opposite direction, turn yo[...]
-
Page 10
T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch wire switch wire connections in the switch housing. connections in the sw[...]
-
Page 11
11 11 14 6 4 9 7 8 5 10 1 2 3 12 16 15 17 18 24 23 22 20 13 19 21 20 13 R epair Par ts Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • NAME OF ITEM • PART DESCRIPTION • MODEL NUMBER The model number of[...]
-
Page 12
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73620001 Printed in China 02/09 Form No. BP7362-1 R epair Par ts Listing Model Numbers Key N o. Description CF775AW02 CF775BS02 CF775ORB02 * Hanger Ball Assembly, 760750-41 760750-24 760750-48 Consisting of: 1 Hanger Bracket — — — 2 [...]