A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF930BS01, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF930BS01 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF930BS01. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF930BS01 should contain:
- informations concerning technical data of Emerson CF930BS01
- name of the manufacturer and a year of construction of the Emerson CF930BS01 item
- rules of operation, control and maintenance of the Emerson CF930BS01 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF930BS01 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF930BS01, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF930BS01.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF930BS01 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 1 1 -1 1[...]

  • Page 2

    YL[...]

  • Page 3

    Supplied l. T wo 60-watt candelabra bulbs[...]

  • Page 4

    k l[...]

  • Page 5

    5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. General Y our Emerson ceiling fan comes supplied with a Fan/Light W all Control which consists of a wall control (transmitter) and a remote [...]

  • Page 6

    6 1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the clevis pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5. 2. Loosen setscrew in motor coupling if necessary . Separate, untwist and unkink the three[...]

  • Page 7

    [...]

  • Page 8

    [...]

  • Page 9

    9 2. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 12). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 1 1). Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until brack[...]

  • Page 10

    10 SW101 F AN/LIGHT WALL CONTROL (SUPPLIED) BLACK BLACK WHITE RED BLACK WHITE HANGER BALL GREEN WIRE (GROUND) FROM HANGER BALL AND HANGER BRACKET TWO-CONDUCTOR CABLE (WITH GROUND) BLACK (HOT) WHITE GROUND TO 120- VOL T SUPPL Y WHITE BLUE WHITE BLUE EMERSON ® HI MED LOW FAN OFF LIGHT ON OFF Figure 14 Check to see that all connections are tight, inc[...]

  • Page 11

    [...]

  • Page 12

    Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control. ! W ARNING 12 Installation of W all Control SINGLE-POLE INST ALLA TION (Figure 19) 1. Disconnect power at circuit breaker or remove fuse. 2. Remove faceplate and screws from existing wall control. Pull control out from the wall box. Determine the “[...]

  • Page 13

    5. Connect one black wire of the wall control to both remaining traveler wires in the wall box and secure with wire connector supplied. NOTE: Retrofit 3-way installations are likely to include two traveler wires between the two wall boxes. In new construction, only one traveler wire Is required. 3-WA Y WIRlNG DIAGRAM: NEW CONSTRUCTION 6. Place wall[...]

  • Page 14

    14 ST ANDARD WIRING FOR EXISTING 3-WA Y CONTROL: HOT BLK F AN/LIGHT WALL CONTROL BLK TRA VELER WIRES BLK BLK BLACK LOAD BLACK LOAD TRA VELER WIRES HOT BLK EXISTING WALL CONTROL EMERSON ® EMERSON ® HI MED LOW FAN OFF LIGHT ON OFF HI MED LOW FAN OFF LIGHT ON OFF Figure 22 Operating Y our Ceiling Fan IMPORT ANT Fan installation must be completed, in[...]

  • Page 15

    1. Downrod Extension Kits (see store or catalog). 2. Ceiling Fan Controls (see store or catalog). 3. Blades (see store or catalog). 15 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING The use of any other control not specifically approved for this [...]

  • Page 16

    [...]

  • Page 17

    -1 -1 -1 762670-5 762670-5 762670-5[...]

  • Page 18

    18 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. W ARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan. to fan. 3. Fan/Light W all Control is OFF. 3. T ur[...]

  • Page 19

    19 LIMITED WARRANTY What The W ar ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor , this[...]