A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CW, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CW one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson CW. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson CW should contain:
- informations concerning technical data of Emerson CW
- name of the manufacturer and a year of construction of the Emerson CW item
- rules of operation, control and maintenance of the Emerson CW item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CW alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CW, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CW.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CW item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Precision Cooling For Business -Critic al C ontinuity™ Li eber t ® CW ™ Syst em Desi gn Manu al - 26-181kW , 50 & 60Hz[...]
-
Page 2
[...]
-
Page 3
i T ABLE OF CONTENTS L IEBERT CW M ODEL N UMBER N OMENCL ATURE . . . . . . . . . . . . . . . . . . . . . . I NSIDE F RONT C OVER 1.0 L IEBERT CW P ERFORMANCE D AT A —50 & 60 H Z S YSTEMS . . . . . . . . . . . . . . . . . . . . . . . . 2 2.0 L IEBERT CW P ERFORMANCE D AT A —M ODELS WITH EC F ANS , 50 & 60 H Z . . . . . . . . . . . . 4 3.[...]
-
Page 4
ii[...]
-
Page 5
1 L IEBERT CW M ODEL N UMBER N OMENCLATURE CW CW = Liebert CW Floor Mount Chilled W ater Unit 1 14 D C S 2 1234 A Nominal Capa city , kW D = Downflow U = Up flow C = Chilled W ater S = Forward-Curved Centrifuga l Fan with S t andard Motor V = Forward-Curved Centrifuga l fan with V ariable Speed Drive 1 = EC Motorized Impeller 2 = 2-W ay V alve, Sta[...]
-
Page 6
Liebert CW Performance Data—50 & 60 Hz Syste ms 2 1.0 L IEBERT CW P ERFORMANCE D AT A —50 & 60 H Z S YSTEMS CW026 CW038 CW041 CW051 CW060 CW076 CW084 CW106 CW114 Capacity Data BTU/Hr (kW) {Based on 45°F (7 .2°C) Entering Water. 10°F (5.6°C) Water Rise} 80°F DB, 66.8°F WB (26.6°C D B, 19.3°C WB) 50% RH Total - kBTUH (kW) 142 (41.[...]
-
Page 7
Liebert CW Performance Data—50 & 60 Hz Syste ms 3 CW026 CW038 CW041 CW051 CW060 CW076 CW084 CW106 CW114 Fan Section - Variable Pitch, Two-Belt Dri ve Package* (*Some options or combination of options may result in reduced air flow. Consult factory for recommendation.) Air Volume CFM (CMH) 5250 (8920) 6050 (10,280 ) 5900 (10,020) 9300 (15,800)[...]
-
Page 8
Liebert CW Performance Data—Mo dels with EC Fans, 50 & 60 Hz 4 2.0 L IEBERT CW P ERFORMANCE D AT A —M ODELS WITH EC F ANS , 50 & 60 H Z CW106D CW114D CW181D Capacity Data BTU/Hr (kW) {Based on 45°F (7.2°C) Entering Water. 10°F Water Rise} 75°F DB, 62.5°F WB (23.9°C DB, 16.9°C WB ) 50% RH * Total -kBTUH (kw) 435 (127.5) 552 (161.7[...]
-
Page 9
Electrical Data—Units with EC Fans 5 3.0 E LECTRICAL D AT A —U NIT S WITH EC F ANS 3.1 CW106 and CW1 14 Electri cal Dat a with EC Fans 3.2 CW181 Electrical Da t a with EC Fans T able 1 Electrical dat a—60Hz-3 phase Reheat Humidifier Volts FLA WSA OPD Electric Infrared 460 65.4 81.8 90 Electric Infrared 575 53.4 66.8 70 Electric Infrared 460 5[...]
-
Page 10
Dimensional Data 6 4.0 D IMENSIONAL D AT A Figure 1 Dimensions, CW026 - CW084 Model Dimensional Data. inches (mm) Net Weight lb (kg) AB C D E F G H J K CW026 50 (1270) 46 (1168) 35 (889) 32 (813) 48 (1219) 33 (883) 8 (203) 37 (940) 35-5/8 (905) 31 (787) 760 (345) CW038 50 (1270) 46 (1168) 35 (889) 32 (813) 48 (1219) 33 (883) 8 (203) 37 (940) 35 5/8[...]
-
Page 11
Dimensional Data 7 Figure 2 Dimensional Dat a—50 & 60 Hz Systems CW106—CW1 14, downflow models Model Dimensional Data, inches (mm) Net Weight lb (kg) AB C D E F G H I CW106 122 (3099) 118 (2997) 35 (889) 31 (787) 120 (3048) 33 (838) 35-5/8 (905) 30 (762) 34 (864) 1785 (810) CW114 1925 (873) UNIT DI MEN SI ONAL DA T A Projection of Display B[...]
-
Page 12
Dimensional Data 8 Figure 3 Cabinet and Floor Pla nning Dimensiona l Dat a, Downflow Model CW181 with EC Fans Note: D imensions do not include fil ter plenum shipped s eparate and field-A instal led. DPN 001694 REV 0 Note: E lectri cal connecti ons can be made from the bottom of the unit. FRON T VI EW TOP V IE W Shaded a rea indicates the required [...]
-
Page 13
Dimensional Data 9 Figure 4 Cabinet and floor planning dimension s, up flow models—CW026 -CW084 Model No. of Blowers Dimensional Data, inches (mm) Net Weight, lb (kg) ABCD E F G H J K LM CW026 1 50 (1270) 48 (1219) 46 (1168) 44 (1118) 3 (76) 5 (127) 18 (457) 15-7/8 (403) 18-5/8 (473) 2-3/16 (55) 17-3/8 (454) — 760 (345) CW038 1 50 (1270) 48 (12[...]
-
Page 14
Dimensional Data 10 Figure 5 Cabinet and floor plannin g dimensions, CW 106 and CW1 14 upf low models Unit Dime nsional Data Air grille suppli ed on units with front return air only Shaded are as indicate a recommended c learance of 36" (914mm) f or component access and filte r remova l. Duct Co nn ection Data Models With R ear Return Projec t[...]
-
Page 15
Upflow Duct Conne cti on Data CW026—CW084 11 5.0 U P FLOW D UCT C ONNECTION D AT A CW026—CW084 No. of Blowers Model No. Chilled Water Dimensional Data—in. (mm) A BCD E F G H J 1 CW026 15-7/8 (403) 18-5/8 (473) 2-3/ 16 (55) 17-7 /8 (454) - 50 (1270) 35 (889) 44 (111 8) 18 (457) 1 CW038 15-7/8 (403) 18-5/8 (473) 2-3/16 (55) 17-7 /8 (454) - 50 ([...]
-
Page 16
Blower Duct & Deck Dimensions, CW106 and CW1 14, Upflow Models 12 6.0 B LOWER D UCT & D ECK D IMENSIONS , CW106 AND CW1 14, U P FLOW M ODELS Model Blower Supply Motor, hp Dimensional Data, inches (mm) Net Weight lb. (Kg) AB C D E F CW106 15 x 15 Top Front 10-15 27-1/2 (699) 3 1/2 (89) 18-11/16 (475) 16-3/16 (411) 10 (254) 4 1/2 (114) 1785 ([...]
-
Page 17
Electrical Specifications 13 7.0 E LECTRICAL S PECIFICATIONS T able 5 Electrical dat a—50 Hz systems Reheat Options Electric None Electric None Humidifier Options IR/SGH IR/SGH Steam or None Steam or None Models Motor HP Volts 200 230 380-415 200 23 0 380-415 200 230 380-415 200 230 380-415 CW026 2.0 FLA 46.7 43.4 24.3 19.8 17.2 9 .9 33.9 32.3 17[...]
-
Page 18
Electrical Specifications 14 T able 7 Electrical dat a—60 Hz Systems Chilled Water Model s - 60Hz Reheat Options Electric None Electric El ectric Humidifier Options Infrared or St eam Generating Infrared or Steam Generating Steam or None Steam or None Models / Motor HP Volts 208 230 460 575 208 230 460 575 208 230 460 575 208 230 460 575 CW026 2.[...]
-
Page 19
Electrical Specifications 15 CW106 20.0 HP (Upflow only) FLA 165.1 154.8 77.7 63.7 86.0 76.2 3 8.6 33.6 138.5 132.6 66. 1 52.1 59.4 54.0 27.0 22.0 WSA 206.4 19 3.5 97.1 79.6 107.5 95.3 48.3 4 2.0 173.1 165.8 82.6 65.1 7 4.3 67.5 33.8 27.5 MFCB 225 2 00 110 90 150 125 70 60 200 200 90 70 125 110 60 45 CW114 10.0 HP FLA 136.5 128.8 64.7 52.7 57.4 50.[...]
-
Page 20
Guide Specifications 16 G UIDE S PECIFICATIONS 1.0 G ENERAL 1.1 Summary These specifications describe requirements for a precision environmental control system. The system shall be design ed to main tain temperature conditio ns in the r ooms containing electronic equipment. The manufacturer shall design and furnish all equip men t to be fully compa[...]
-
Page 21
Guide Specifications 17 System Auto Restart - The auto restart feature will automa tically restart the system after a power failure. Time dela y is programmable. Sequential Load Activation - On in itial startup or restart after po wer failure, each operational load is sequenced with a minimum of one seco nd delay to minimize total inrush current. H[...]
-
Page 22
Guide Specifications 18 The Service Menus Shall be Defined as Follows Setpoints : Menu shall allow setpoin ts within the following ranges: • Temperature Setpoint 65-85ºF (18-29ºC)* • Temperature Sensitivity +1-10ºF (0.6-5.6ºC) • Humidity Setpoint 20-80% RH* • H umidity Sensitivity 1 -30% RH • High Temperature Alarm 35-90ºF (2-32ºC) [...]
-
Page 23
Guide Specifications 19 Advanced Menus Factory Settings : Configuration settings shall be fa ctor y-set based on the pre-defi ned component operation. Change Passw ords : Menu shall allow new passwords to be set or changed. 2.4.1 Liebert iCOM Microprocessor Control With L arge Graphic Display (Optional) The Liebert iCOM unit control with large grap[...]
-
Page 24
Guide Specifications 20 2.5.1.4 Alarms The Liebert iCOM control shall activate an audibl e and visual alarm in event of any of the foll owing conditions: • H igh Temperature • Low Temperature • H igh Humidity • Low Humidity • Main Fan Overload (opt) • Change Filters • Loss of Air Flow • Loss of Power • Custom Alarm (#1 to #4) Cust[...]
-
Page 25
Guide Specifications 21 2.7 High Pressure Chilled W ater Control V alve—Optional The chilled wa ter circuit shall inclu de a 3-way (2-way ) high pressure modu lating valve. The valve shall be designed for up to 400 PSI (2758 kPa) water pressure. 2.8 A-Frame Chilled W ater Coil The cooling coil shall be of A-frame design with a minimum of __ __ sq[...]
-
Page 26
Guide Specifications 22 2.1 1.6 Floor St and The floor stand shall be constructed of a heliarc- welded, tubular steel frame. The floor stand shall have adjustable legs wit h vibration isolation pa ds. The floor stand shall be ____ inches high. 2.1 1.6.1 Floor St and T urning V ane A factory-supplied , field-mounted turning vane shall be provided. 2[...]
-
Page 27
[...]
-
Page 28
Ensuring The Hi gh A vai lab ilit y Of Mission-Critic al Data An d Appli c ations. Emerson Net work P ow er , the global leader in enabling business-critical continuity , ensures network re siliency and adaptabilit y through a family of technologies—inc luding Liebert power and cooling technologies—that prot ect and suppor t business-critical s[...]