Emerson E-DESIGN 150-400A manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson E-DESIGN 150-400A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson E-DESIGN 150-400A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson E-DESIGN 150-400A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson E-DESIGN 150-400A should contain:
- informations concerning technical data of Emerson E-DESIGN 150-400A
- name of the manufacturer and a year of construction of the Emerson E-DESIGN 150-400A item
- rules of operation, control and maintenance of the Emerson E-DESIGN 150-400A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson E-DESIGN 150-400A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson E-DESIGN 150-400A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson E-DESIGN 150-400A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson E-DESIGN 150-400A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    381333–128 D 50 Hanove r Road, F lorham Park, New J ersey 07932–1591 USA For sales or service call 1 800 800–2726 (A SCO ) www.ascopower .com AS CO PO WER TECH NO LOGI E S CA NA DA PO Box 1238, 17 Airport R oad, Brantf ord, O ntario, Can ada N 3T 5T3 Operator’s Manual 7000 Serie s ACT S Automatic Closed– T ransition T r ansfer S witches E[...]

  • Page 2

    Ca talog Num ber Identif icatio n T ypical 7000 Serie s catalog no. for E–design switched neutra l, 3 pole, 400 amp, 480 V , A CTS i n T ype 1 e nclosure: 7AC T S C 3 400 N 5 C Phase Poles Neutral A –s o l i d Amperes Vo l t a g e Co ntro ller Enc los ure B –s w i t c h e d 5X –i f accessor ies order ed 5 –s t a n d a r d G –t y p e4 C [...]

  • Page 3

    SECT ION 1 INST ALLA TION 1 --- 1 A SCO Se ries 7000 A utomatic Closed–T ransi ti on T ransfe r Sw itches ar e factory w ired and tes ted. Field in stall ation simply requi res mounti ng and connecti on of service cables, and a uxi liary control circui ts (i f re quire d). Remove th e Shipping S kid F or l arge switches, open the front door and r[...]

  • Page 4

    INST ALLA TION (cont inued) 1 --- 2 Tig hten bol ted joints to the torqu e specified in T able A . The re lia b l ility o f the c on ne ctio n dep en ds on how cle an and how ti ght t he joi nt is . T able A. Ti ghtening torque val ues for bol ted joints (Grade 5 hardware) Bol t Diameter in inche s Ti ghtening T orque in foot pou nds 1/4 7 5/16 12 [...]

  • Page 5

    INST ALLA TION (cont inued) 1 --- 3 handle handle shafts handle Figure 1- 2. Figure 1- 3. Figure 1- 4 150 – 400 A (3 pole) 600 & 800 A (& 4 pole 400 A) 3000 & 4000 A E–design switches F–desi gn switches F–desi gn transfer switches 1 – Manual Operation A detac habl e manual oper ator handl e is provided on the Tr a n s f e r S [...]

  • Page 6

    INST ALLA TION (cont inued) 1 --- 4 obse rve these li ghts RED RED RED RED RED GREEN GREEN Figure 1- 6. Standard control s and indicators. 2 --- V o l t a g e C h e c k s First check nameplate o n tra nsfer swit ch; rated volta ge m u s tb et h es a m ea sn o r m a la n de m e r g e n c yl i n ev o l t a g e s . V erify that t he feeders have been [...]

  • Page 7

    INST ALLA TION (cont inued) 1 --- 5 obse rve these li ghts RED RED RED RED RED GREEN GREEN oper at e this s w itch Figure 1- 7. Standard control s and indicators. 3 - - - Electr ical Oper atio n Th i s pr oce du re wi ll che ck t he e le ctr ica l o pe ra ti o n o f t he A utomatic Clo sed–T ransition T ransfer Switc h. See F i g u r e 1 --- 7 . [...]

  • Page 8

    SECT ION 2 TEST ING & SERVIC E 2 --- 1 TRANS FER TEST Operate t he 7000 Series ACTS at least once a month by foll owing the five–step Elect rical Op eration Tr a n s f e r Te s t procedure on page 1–5. PREV ENTIV E MAIN TENAN CE R easonab le c are in pr eventive m ainten ance w ill ins ure high reliabilit y and long l if e for the 7000 Seri[...]

  • Page 9

    TEST ING & SERVIC E (continued) 2 --- 2 MANUAL L OAD TR ANSFER This pr oced ure w ill m anual ly tr ansfer th e load if th e cont ro lle r is d i sco nne ct ed . Do no t manua ll y op erate the transfer switch until both po wer so urces are disconnected (al l co nductors deenergized). 1. Deenerg ize both the n ormal an d emerg ency sou rce cond[...]

  • Page 10

    INDEX Printed in U .S.A. Copy right 2009 ASCO Power T echnologies, L .P . A alarm reset, 1–5, 2–2 auxil iary cir cuits , 1–2 C cable lugs, 1–2 prepar ation, 1–2 cat alo g nu mber, in si de co ve r cleaning, 2–1 closed transi ti on bypass, 1–5, 2–2 connections line, 1–1 controller, 1–1 disconnecting, 2–1 see Controller Us er’[...]