Go to page of
Similar user manuals
-
Network Card
Emerson P/N MMI-20019808
78 pages 1.16 mb -
Network Card
Emerson SiteLink-2E
4 pages 0.57 mb -
Network Card
Emerson Bristol ControlWave PAC Redundancy
2 pages 0.27 mb -
Network Card
Emerson MONITORING OpenComms
56 pages 2.17 mb -
Network Card
Emerson SiteI/O 10/0
6 pages 0.31 mb -
Network Card
Emerson 00825-0100-4075
28 pages 1.36 mb -
Network Card
Emerson Bristol Helicoid Gauges
1 pages 0.24 mb -
Network Card
Emerson RFC2132
2 pages 0.3 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson SiteI/O 32/0, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson SiteI/O 32/0 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson SiteI/O 32/0. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson SiteI/O 32/0 should contain:
- informations concerning technical data of Emerson SiteI/O 32/0
- name of the manufacturer and a year of construction of the Emerson SiteI/O 32/0 item
- rules of operation, control and maintenance of the Emerson SiteI/O 32/0 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson SiteI/O 32/0 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson SiteI/O 32/0, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson SiteI/O 32/0.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson SiteI/O 32/0 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Specification for SiteI/O 32/0 DESCRIPTION: The SiteI/O 32/0 is part of the SiteI/O-L ine, which allows a complete SiteScan monitoring/control system to be built a pi ece at a time. It is a 32 bit microprocessor-based device designed to monitor up to thirty-two ana log, digital, and/or dry contact type signals. Individual hardware jumpers set signa[...]
-
Page 2
Specification for SiteI/O 32/0 BATTERY: Seven-year lithium battery provides a minimum of 10,000 hours of data retention during power o utages. DIAGNOSTIC LED's: Power: Indicates power on condition Tx: Indicates data transmitted on the CMnet Rx: In dicates data received on the CMnet Error: Indicates an error within the SiteI/O 10/0 Run: Indicat[...]
-
Page 3
Specification for SiteI/O 32/0 INPUT WIRING DIAGRAM PW R OU T GND 0-5 V DC DR Y CON TAC T 3W I R E 4-20 m A 4W I R E 4-20 m A ISOLATED DC PO W ER SU PPLY PW R OUT GND PW R OUT+ GND OU T- OUT+ OU T- Univ ersa l Inp ut Mod e S elect V+ PA SS I VE TRA N SDU CER TO MO D U LE GN D THER M ISTOR 4-2 0 m A 12V or 24 V LOO P IN P UT A B A B A B A B A B A B [...]
-
Page 4
Specification for SiteI/O 32/0 COMMUNICATIONS WI RING DIAGRAM N e t - N e t + S h i e l d N e t - N e t + C M n e t 18-24 ga Twisted - Pair, Shielded, Low Impedance, Low Capacit anc e Recommended wire is: Magnum Cable A3-ARC-156-2 ENLOSURE DIAGRAMS Liebert Corporation Page 4 of 5 SL- 28073 Rev. 4; 7/03[...]
-
Page 5
Specification for SiteI/O 32/0 Enclosure Wall Mounting Enclosure Floor Mounting with Brackets Liebert Corporation Page 5 of 5 SL- 28073 Rev. 4; 7/03[...]