Go to page of
Similar user manuals
-
Fan
Emerson CF935WB00
8 pages 0.19 mb -
Fan
Emerson CF980MAB 00
16 pages 0.32 mb -
Fan
Emerson CF711PBOO
12 pages 0.19 mb -
Fan
Emerson CF3900BQ01
12 pages 0.21 mb -
Fan
Emerson CF3900CK01
12 pages 0.21 mb -
Fan
Emerson CF652WW00
8 pages 0.13 mb -
Fan
Emerson CF244CRM00
20 pages 0.29 mb -
Fan
Emerson CF930BS01
20 pages 5.24 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson TCDVTM, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson TCDVTM one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson TCDVTM. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson TCDVTM should contain:
- informations concerning technical data of Emerson TCDVTM
- name of the manufacturer and a year of construction of the Emerson TCDVTM item
- rules of operation, control and maintenance of the Emerson TCDVTM item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson TCDVTM alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson TCDVTM, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson TCDVTM.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson TCDVTM item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Precision Cooling For Business -Critic al C ontinuity™ Li eber t V F D Co nden ser — M o del T C D V ™ Product Information Man ual - 50/60Hz[...]
-
Page 2
[...]
-
Page 3
i T ABLE OF CONTENTS 1.0 I NTRODUCTI ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Application . . . . . . . . . . . . . . [...]
-
Page 4
ii[...]
-
Page 5
Introd uction 1 1.0 I NTRODUCTION 1.1 Description The Liebert VFD Control Condenser, Model TCD V, is an air cooled direct-drive refrigeration con- denser designed to reject the heat from a precision air conditioning unit to the outdoor air. The con- denser uses a Variable Frequency Dri ve (VFD) to control fan speed, which provides positive refriger[...]
-
Page 6
Introd uction 2 Figure 2 Major electrical contr ol component s T able 1 Electrical dat a—50 and 60 Hz Model # 165, 205 251, 308 415, 510 Number of Fans 2 3 4 Input Voltage Ph Hz Motor Hp FLA WSA OPD FLA WSA OPD FL A WSA OPD 208/230 3 60 0.75 7.2 8.1 15 10.7 11.6 15 14.2 15.1 20 460 3.5 4.0 15 5 .2 5.7 15 6.9 7.4 15 200/230 50 7.2 * * 10.7 * * 14.[...]
-
Page 7
Introd uction 3 T able 3 Condenser perfor mance, 60Hz Model Number T ot al Heat Reje ction BT U/Hr (kW) Based on TD CFM (CMH) Sound dBA Fan Qty 30°F TD (16.7°C) 25°F TD (13.9°C) 20°F TD (1 1.1°C) 15°F TD (8.3C) 1°F TD (0.6°C) R-22 Refrigerant TCDV165 178,410 (52.2) 148,675 (43.5) 118,940 (34.8) 89,205 (26.1) 5,947 (3.1) 13,300 (22,597) 75.[...]
-
Page 8
Introd uction 4 T able 4 Condenser perfor mance, 50Hz Model Number Total Heat Rejection BTU/hr (kW) based on TD CFM (CMH) Sound dBA Fan Qty 30°F TD (16.7° C) 25°F TD (13.9°C) 20°F TD (11.1°C) 15°F TD (8.3°C) 1°F TD (0.6°C) R-22 Refrigerant TCDV165 162,660 (47.6) 135,550 (39.7) 108,440 (31.8) 81,330 (23.8) 5,422 (2.9) 11,100 (18,859) 71.0 [...]
-
Page 9
Dimensional an d Electrical Data 5 2.0 D IMENSIONAL AND E LECTRICAL D AT A Figure 3 Cabinet and anchor dimens ional dat a—VFD control condensers , 50 and 60Hz T able 5 Physical dat a—VFD control co ndensers, 50 and 60Hz Model # Number of Fans A B C D Net Weight in (mm) in (mm) in (mm) in (mm) lb (kg) TCDV165 2 91-1/2 (2324) 84 (2134) 82 (2083) [...]
-
Page 10
Dimensional an d Electrical Data 6 Figure 4 Electrical field conne ctions, VFD control c ondensers A larm Connections Field-supplied 24V Class 1 wiring to remote alarm circuits V ariable Frequency Drive (VFD) alarm contact connections (1 1, 12) T ransient V oltage Surge Suppressor (TVSS) alarm contact connections (13, 14). Factory-wired to 24V cont[...]
-
Page 11
Guide Specifications 7 3.0 G UIDE S PECIFICATIONS 3.1 General Each condenser shall consist of hous ing, condenser coil, pr opeller fans direct-dri ven by indivi dual fan motors, fan guards, electrical co ntrols and mounting legs. The ai r-cooled condense r shall have a _____volt, 3-phase, _____ Hz power supply. 3.2 Coil Liebert manufact ured coil s[...]
-
Page 12
Ensuring The Hi gh A vai lab ilit y 0f Mission-Critic al Dat a And Ap plic ations. Emerson Net work P ow er , the global leader in enabling business-critical continuity , ensures network resiliency and adaptabilit y through a family of technologies—inc luding Liebert power and cooling technologies—that prot ect and suppor t business-critical sy[...]