Go to page of
Similar user manuals
-
Indoor Fireplace
Empire Comfort Systems PV-28SV55-(C,G)(N,P)-1
56 pages 3.7 mb -
Indoor Fireplace
Empire Comfort Systems VF24FP2-1
28 pages 3.02 mb -
Indoor Fireplace
Empire Comfort Systems DVP48FP9(1,3)(N,P)-1
56 pages 3.59 mb -
Indoor Fireplace
Empire Comfort Systems DVF-36IP-2
39 pages 1.27 mb -
Indoor Fireplace
Empire Comfort Systems VFP36SP32EP-2
40 pages 7.6 mb -
Indoor Fireplace
Empire Comfort Systems CIDV-30-7
30 pages 1.43 mb -
Indoor Fireplace
Empire Comfort Systems DVP42FP3(0,1,2,3)(N,P)-1
56 pages 3.59 mb -
Indoor Fireplace
Empire Comfort Systems VFP36FP
28 pages 1.93 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Empire Comfort Systems VFD32FB2DL-1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Empire Comfort Systems VFD32FB2DL-1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Empire Comfort Systems VFD32FB2DL-1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Empire Comfort Systems VFD32FB2DL-1 should contain:
- informations concerning technical data of Empire Comfort Systems VFD32FB2DL-1
- name of the manufacturer and a year of construction of the Empire Comfort Systems VFD32FB2DL-1 item
- rules of operation, control and maintenance of the Empire Comfort Systems VFD32FB2DL-1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Empire Comfort Systems VFD32FB2DL-1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Empire Comfort Systems VFD32FB2DL-1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Empire Comfort Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Empire Comfort Systems VFD32FB2DL-1.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Empire Comfort Systems VFD32FB2DL-1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Page 1 23200-0-1206 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL The Breckenridge Deluxe V ent-Free Universal Fireboxes DO NOT A TTEMPT TO MODIFY OR AL TER THE CONSTRUCTION OF THE FIREBOX OR ITS COMPO- NENTS. ANY MODIFICA TION OR AL TERA TION OF CONSTRUCTION MA Y VOID THE W ARRANTY OF THIS FIREBOX. CHILDREN AND ADUL TS SHOULD BE ALERTED TO T[...]
-
Page 2
23200-0-1206 Page 2 SECTION P AGE Important Safety Information ................................................................................................. 3 Introduction ............................................................................................................................ 3 Clearances ....................................[...]
-
Page 3
Page 3 23200-0-1206 The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition) and to the National electrical Code, ANSI/NFP A70 (latest edition). NO TE: I nst al la tio n and r ep air sho ul d be done by a qua li - fied service person. The appliance should be in[...]
-
Page 4
23200-0-1206 Page 4 Clearances to combustibles Sidewall Clearances: The clearance from the inside of the firebox to perpendicular combustible side wall should not be less than 6". See Figure 1. Fir ebox Side and Bac k Clearances: The firebox outer casing side and back flanges are zero clearance to combustibles. T op Framing and Finishing: C[...]
-
Page 5
Page 5 23200-0-1206 Deluxe V ent-Free Firebox Framing Dimensions (in inches) "A" "B" "C" Model Framing Height Framing W idth Framing Depth VFD32FB 36 1/8" 35" 17" VFD36FB 38 1/8" 40" 19 3/8" VFD42FB 38 1/8" 44" 19 3/8" Attention: Add 3-3/4" to "A" Dimension wh[...]
-
Page 6
23200-0-1206 Page 6 Figure 7 Firebox Dimensions H J K I A G F B E H I A G F B E C D L M DELUXE LOUVERED DELUXE FLUSH FIREBOX INST ALLA TION INSTRUCTIONS (continued) DELUXE REFERENCE LETTER LOUVERED FLUSH VFD32 VFD36 VFD42 VFD32 VFD36 VFD42 A 35 5/8" 37 5/8" 37 5/8" 35 5/8" 37 5/8" 37 5/8" B 34 1/2" 39 1/2" 43[...]
-
Page 7
Page 7 23200-0-1206 Locating Firebox Place firebox in framing opening. Use the four (4) framing brackets provided on the firebox to attach firebox to framing. Different hole locations can be used for finishing materials with thicknesses of 3/8", 1/2" and 3/4". Attach these materials with screws provided, two (2) per framing brack[...]
-
Page 8
23200-0-1206 Page 8 The fireb ox is desi gned to accept a 3/8- inch gas line for an appr oved vent-free gas logset. Have the line installed by a qualified service pers on in accord ance with all buil ding code s. Consul t local buil ding codes to properly size the gas supply line leading to the 3/8-inch hook-up at the unit. The state of Massachus[...]
-
Page 9
Page 9 23200-0-1206 OPTIONAL FRESH AIR KIT INST ALLA TION INSTRUCTIONS FOR DELUXE AND PREMIUM FIREBOXES 4. Next, with the vise grip attached, feed the long control rod through the small rectangular opening at the left side of the firebox face. Carefully position the rod and bracket so that the bracket can be secured to the inside opening of the ?[...]
-
Page 10
23200-0-1206 Page 10 with the hole in the front flange of the movable air door . See Figure 18. 7. Once the control rod is fed through the air door hole, gently lift the outer air door plate assembly inward and upward until the mounting holes in the plate line up with the pilot holes in the side wrap. 8. Install (4) screws to retain the Air Door a[...]
-
Page 11
Page 1 1 23200-0-1206 Completion of Air Kit installation 1. Determine the length of 4” Dia. rigid or flex duct connector (installer supplied) you will need from the firebox/fireplace to the exterior surface of the outside wall, where the air kit hood will be installed. Add a few extra inches to the length to allow for easier attachment of the [...]
-
Page 12
23200-0-1206 Page 12 OPTIONAL SINGLE SPEED BLOWER INST ALLA TION INSTRUCTIONS Attention: Install blower assembly before connecting gas inlet supply line. Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFP A 70 , if an exter[...]
-
Page 13
Page 13 23200-0-1206 4. Insert blower assembly into interior , bottom of firebox. Posi- tion blower assembly so that you align the notch on back of blower assembly with the center screw on firebox back, then push the blower assembly against firebox back. The blower wheel must be centered with the back wall of the firebox. The magnets on the bac[...]
-
Page 14
23200-0-1206 Page 14 Blower Motor The blower motor does not have oiling holes. Do not attempt to oil the blower motor . Blower Wheels The blower wheels will collect lint and could require periodic cleaning. If the air output decreases or the noise level increases, it indicates a dirty blower wheel. Remove fan and clean blower wheels. W arning: Unpl[...]
-
Page 15
Page 15 23200-0-1206 CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCA L, CITY AND ST A TE BUIL DING CODE S. BEFORE MAKING THE ELECTR ICAL CONNEC TION, MAKE SURE THA T MAIN POWER SUPPL Y IS DISCONNECTED. THE APPLIANCE, WHEN INST ALLED, MUST BE ELECTRICALL Y GROUNDED IN ACCORDANCE WITH LOCAL CODES[...]
-
Page 16
23200-0-1206 Page 16 P AR TS LIST ITEM P ART NUMBER DESCRIPTION VFD32FB0L VFD32FB2DL VFD32FB2CL VFD32FB0F VFD32FB2DF VFD32FB2CF 1 17149 17149 17149 17149 17149 17149 TOP ST ANDOFF 2 17169 17169 17169 N/A N/A N/A UPPER LOUVER 3 10554 10554 10554 10554 10554 10554 FRAMING BRACKET 4 17170 17170 17170 N/A N/A N/A LOWER LOUVER 5 17162 17162 17162 17162 [...]
-
Page 17
Page 17 23200-0-1206 Parts can be ordered through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number . When ordering parts, first obtain the Model Number from th[...]
-
Page 18
23200-0-1206 Page 18 P AR TS VIEW 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 1 16 17 17[...]
-
Page 19
Page 19 23200-0-1206 Accessory Description Model Numbers Fan Kit 1 2 Designed to provide forced air flow . FBB5 V ariable Speed Control Kit W all mounted variable speed control for use with FBB5 blower SCV -1 Brick Liners Deluxe Firebox VBP32SA VBP36SA VBP42SA Fresh Air Kit 1 2 8 4 7 6 5 3 Deluxe and Premium Fireboxes BV A-1 Frame Kits Standard 3-[...]
-
Page 20
23200-0-1206 Page 20 Extended 4" Hoods Extended hoods that extend out 2" farther than the standard hoods, to accommodate thicker surround materials. A vailable as optional kits in Brass, Hammered Pewter , and Stainless Steel finishes. Contact dealer for all available optional hood accessories Louvers Styles include Slat, Mission, Arch, a[...]