Empire Comfort Systems VFDR24LB manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Empire Comfort Systems VFDR24LB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Empire Comfort Systems VFDR24LB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Empire Comfort Systems VFDR24LB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Empire Comfort Systems VFDR24LB should contain:
- informations concerning technical data of Empire Comfort Systems VFDR24LB
- name of the manufacturer and a year of construction of the Empire Comfort Systems VFDR24LB item
- rules of operation, control and maintenance of the Empire Comfort Systems VFDR24LB item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Empire Comfort Systems VFDR24LB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Empire Comfort Systems VFDR24LB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Empire Comfort Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Empire Comfort Systems VFDR24LB.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Empire Comfort Systems VFDR24LB item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Page 1 21565-3-0906 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED GAS LOG HEA TER OR VENTED DECORA TIVE APPLIANCE MODELS VFDR18LB(N,P)-1 VFDR24LB(N,P)-1 VFDR30LB(N,P)-1 EFFECTIVE DA TE SEPTEMBER 2006 V ented/V ent-Fr ee Burner and Logs This is an unvented gas-fired heater . It uses air (oxygen) fr om the r oom in which it is install[...]

  • Page 2

    Page 2 21565-3-0906 SECTION P AGE IMPOR T ANT SAFETY INFORMA TION ........................................................................................ 3 SAFETY INFORMA TION FOR USERS OF LP-GAS ..................................................................... 4 INTRODUCTION ....................................................................[...]

  • Page 3

    Page 3 21565-3-0906 W ARNING When used without adequate combustion and ventilation air , heater may give off CARBON MONOXIDE, an odorless, poisonous gas. Do not install heater until all necessary provisions are made for combustion and ventilation air . Consult the written instructions provided with the heater for information concerning combustion a[...]

  • Page 4

    Page 4 21565-3-0906 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area[...]

  • Page 5

    Page 5 21565-3-0906 Notice: During initial firing of this unit, its paint will bake out, and smoke will occur . T o prevent triggering of smoke alarms, ventilate the room in which the unit is installed. W ARNING: This appliance is for installation only in a solid- fuel burning masonry or UL 127 factory-built fireplace or in a list ed vent less ?[...]

  • Page 6

    Page 6 21565-3-0906 This is an unvented gas-fired heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Keep room area clear and free from combus tib le materi als, gaso line and other flammable vapors and liquids. Unvented gas heaters are a supplemental zone[...]

  • Page 7

    Page 7 21565-3-0906 ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3. or applicable local codes. Example of Large Room with 1/2 W all divider . Figure 1 The following formula can be used to determine the maximum heater rating per the definition of unconfined space: Btu/Hr = (L 1 + L 2 )FT x ([...]

  • Page 8

    Page 8 21565-3-0906 Mantel Clearances with Hood (Figur e 5) Y ou must have non-combustible materials above the fireplace opening. Non-combustible material must extend at least 8" above fir epl ac e ope ni ng. W ith she et met al , you must ha ve non -c om bu st ibl e material behind it. Heat resistant materials such as slate and marble must [...]

  • Page 9

    Page 9 21565-3-0906 FOR MASONR Y BUIL T FIREPLACES FREE OPEN ING A REA OF CHI MNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORA- TIVE APPLIANCES FOR INST ALLA TION IN SOLID FUEL BURNING FIREPLACES * Height is from hearth to top of chimney and the minimum height is 6 feet. ** Chart shows minimum opening (sq. in.) for given height and input rat[...]

  • Page 10

    Page 10 21565-3-0906 Notice (Damper Clamp Installation) When installing your log set as a vented installation the damper clamp must be used. When installing your log set as a vent-free installation the damper clam p can be used to elimi nate the potenti al for odors when burnin g the logs for the first time. Installing Damper Clamp (Figur e 9) Rem[...]

  • Page 11

    Page 1 1 21565-3-0906 Check all local codes for requirements, especially for the size and type of gas supply line required. Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: Since some municipalities have additional local codes, it is always best to consult your local authority and ins[...]

  • Page 12

    Page 12 21565-3-0906 Before you begin: if you are installing logs onto the VFDR18 or VFDR24 models, this burner assemb ly is supplied with a set of five ceramic fiber logs. Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and wa[...]

  • Page 13

    Page 13 21565-3-0906 Before you begin: If you are installing logs onto the VFDR30 model, this burner assembly place is supplied with a set of seven ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to[...]

  • Page 14

    Page 14 21565-3-0906 Flames from the pilot (rear right back side of the pan burner) as well as the main flame should be visually checked as the log set is installed. In norma l operati on at full rate, the flame appeara nce should be sets of yellow flames above the rear burner section, and shorter blue flames with glowing embers on the front bu[...]

  • Page 15

    Page 15 21565-3-0906 Th e rm o st a t s a re no t ap p ro v ed on v en t ed de c or a t iv e a p pl i a nc e s. Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. V erify proper operation after servicing. 18", 24" and 30" Gas Logs (Millivolt) thermopile is self p[...]

  • Page 16

    Page 16 21565-3-0906 W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING, smell all arou nd the applianc e are[...]

  • Page 17

    Page 17 21565-3-0906 Figure 18 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 19 shows an incorrect pilot flame pattern. The incorr[...]

  • Page 18

    Page 18 21565-3-0906 Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. TURN OFF HEA TER AND ALLOW TO COOL BEFORE CLEANING. Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin b[...]

  • Page 19

    Page 19 21565-3-0906 If the gas quality is bad, your pilot may not stay lit, the burners may pr oduce soot and the heater may backfire when lit. If the gas quality or pressur e is low , contact your local gas supplier immediately . 1. When ignitor button is pressed, there is no spark at ODS/ pilot. a. Ignitor electrode positioned wrong - Replace p[...]

  • Page 20

    Page 20 21565-3-0906 Attention: When ordering parts, it is very important that part number and description of part coincide. USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. P AR TS LIST INDEX NO. P AR T NUMBERS DESCRIPTION VFDR18LB VFDR24LB VFDR30LB 1 21588 21588 21588 PILOT SHIELD (NA T O[...]

  • Page 21

    Page 21 21565-3-0906 P AR TS VIEW Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number . When ordering parts, first obtain the Mo[...]

  • Page 22

    Page 22 21565-3-0906 SER VICE NOTES[...]

  • Page 23

    Page 23 21565-3-0906 SER VICE NOTES[...]

  • Page 24

    Page 24 21565-3-0906 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com[...]