Empire Comfort Systems VFP36FP manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Empire Comfort Systems VFP36FP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Empire Comfort Systems VFP36FP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Empire Comfort Systems VFP36FP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Empire Comfort Systems VFP36FP should contain:
- informations concerning technical data of Empire Comfort Systems VFP36FP
- name of the manufacturer and a year of construction of the Empire Comfort Systems VFP36FP item
- rules of operation, control and maintenance of the Empire Comfort Systems VFP36FP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Empire Comfort Systems VFP36FP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Empire Comfort Systems VFP36FP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Empire Comfort Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Empire Comfort Systems VFP36FP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Empire Comfort Systems VFP36FP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Page 1 20101-0-0306 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED GAS FIREPLACE MODELS VFP32FP(20,21)L(N,P)-1 VFP32FP(30,31)L(N,P)-1 VFP36FP(20,21)L(N,P)-1 VFP36FP(30,31)L(N,P)-1 EFFECTIVE DA TE MARCH 2006 — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T[...]

  • Page 2

    Page 2 20101-0-0306 SECTION P AGE Important Safety Information ................................................................................................. 3 Safety Information for Users of LP Gas ................................................................................. 4 Introduction ...................................................[...]

  • Page 3

    Page 3 20101-0-0306 Wh en us e d wi th out a deq ua te co mbu sti on an d ve nti lat i on air , he ate r ma y gi ve o ff C ARB ON M ONO XID E, a n od orl ess , po iso nou s g as . Do not install heater until all necessary pr ovisions are made for combustion and ventilation air . Consult the written instructions provided with the heater for informat[...]

  • Page 4

    Page 4 20101-0-0306 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area[...]

  • Page 5

    Page 5 20101-0-0306 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with unvented room heater . 3. Installer should show owner how to start and operate unvented room heater . Always consult your local Building Department regard[...]

  • Page 6

    Page 6 20101-0-0306 Model VFP32FP VFP36FP Input Maximum 32,000 36,000 Minimum 22,000 25,000 Minimum Firebox Opening Height without standoff 32 3/4" 34 3/4" W idth 34” 39” Depth 17 3/8" 17 3/8” Gas Inlet 3/8” 3/8” Accessories EK-1 Embers Kit PE-20 Platinum Embers FBB4* V ariable Speed Automatic Blower VPP32A VFP32FP — Cera[...]

  • Page 7

    Page 7 20101-0-0306 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour . Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplementa[...]

  • Page 8

    Page 8 20101-0-0306 The space in the above example is a confined space because the actual BTU/Hr used is more than the maximum BTU/HR the space can support. Y ou must provide additional fresh air . Y our options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door[...]

  • Page 9

    Page 9 20101-0-0306 Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter T ubing, T ype L Outside Diameter Nat. L.P . Nat. L.P . 0-10 feet 0-3 meters 1/2” 12.7mm 3/8” 9.5mm 1/2” 12.7mm 3/8” 9.5mm 10-40 feet 4-12 meters[...]

  • Page 10

    Page 10 20101-0-0306 M in i mu m Wa l l a n d Ce i l in g C l e ar an c e s (Figure 4) Sid ewal l Clea ran ces: The clear ance from the inside of the firep lac e to any combustible wall should not be less than 2". Fireplace Side and Back Clearances: The fireplace outer casing sides and back have zero clearance to combustibles. Ceiling Cleara[...]

  • Page 11

    Page 1 1 20101-0-0306 Do not attach combustible material to the mantel of your fireplace. This is a fire hazard. Figure 6 No greeting cards, stockings or ornamentation of any type should be placed o n or attache d to the firep lace. This is a heating ap pliance. The flow of heat can ignite combustibles. Figure 7 COMBUSTIBLE MA TERIALS[...]

  • Page 12

    Page 12 20101-0-0306 JUNCTION BOX ASSEMBL Y C Figure 8 VFP32FP VFP36FP A 34" 39" B 29" 34" C 17 3/8" 17 3/8" D 31" 36" E 22 7/8" 24 7/8" F 32 3/4" 34 3/4" G 44 7/16" 48" H 44 7/16" 48" I 55 7/8" 60 7/8" J 35 3/4" 37 3/4" FIREPLACE DIMENSIONS[...]

  • Page 13

    Page 13 20101-0-0306 A black hood and trim kit is furnished with each model VFP(32,36)FP fireplace. The hood MUST be installed before the firepl ace is used. Failu re to do so may create a possibl e fire hazard. Atten tion: The hood is located behind top louver duri ng shipmen t of fireplace. Remove top louver for access to hood. The trim kit i[...]

  • Page 14

    Page 14 20101-0-0306 1. Place fireplace in framing opening. 2. Using the four (4) nailing flanges provided with the fireplace, attach two (2) flanges on each side. Attach flanges through prepunched holes. Additional hole locations will be used for different finishing material with thicknesses of 1/2”, 5/8” and 3/4”. Attach these flange[...]

  • Page 15

    Page 15 20101-0-0306 Placement of the glowing embers (rock wool) is very individual and light coverage of the areas indicated will provide your best effects. W e recommend separation of the rock wool by hand and make your coverage as light and fluffy as possible. Place just enough embers on the burner to obtain the glow and a gold yellow flame. D[...]

  • Page 16

    Page 16 20101-0-0306 Flames from the pilot (rear right back side of the pan burner) as well as the main flame should be visually checked as the log set is installed. In normal operation at full rate after 10 to 15 minutes, the flame appearance should be sets of yellow flames. NOTE: All flames will be random by design, flame height will go up a[...]

  • Page 17

    Page 17 20101-0-0306 W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING smell all around the appliance ar ea [...]

  • Page 18

    Page 18 20101-0-0306 W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING smell all around the appliance area f[...]

  • Page 19

    Page 19 20101-0-0306 Figures 13 and 15 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figures 14 a nd 16 show an incorrect p ilot flame pa [...]

  • Page 20

    Page 20 20101-0-0306 Figure 17 W arning: Never use needles, wir es, or similar cylindrical objects to clean the pilot to avoid damaging the calibrated ruby that controls the gas flow . Cleaning and Pilot Maintenance Oxygen Depletion Sensor Pilot (Figur e 17) When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows[...]

  • Page 21

    Page 21 20101-0-0306 If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pr essure is low , contact your local gas supplier immediately . 1. When ignitor button is pressed, there is no spark at ODS/ pilot. a. Ignitor electrode positioned wrong - Replace pi[...]

  • Page 22

    Page 22 20101-0-0306 USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. NOTE: SEE LOG INSTRUCTION MANUAL FOR DET AILS ON LOGS AND EMBERS A TTENTION: When ordering parts, it is very important that part number and description of part coincide. P AR TS LIST Index Number Part Number VFP32FP(20,21[...]

  • Page 23

    Page 23 20101-0-0306 Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number fro[...]

  • Page 24

    Page 24 20101-0-0306 FBB4 Blower Installation Attention: Install blower assembly before connecting gas inlet supply line. Note: Junction box on right side of fireplace must be pre- wired at time of fireplace installation for use with blower assembly . It is recommended that an ON/OFF wall switch be installed that will activate the power supply to[...]

  • Page 25

    Page 25 20101-0-0306 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electrical Code, ANSI/NFP A 70 , if an external electrical source is utilized. This appliance is equipped with a three-pr ong [grounding] plug for your protection against shock[...]

  • Page 26

    Page 26 20101-0-0306 CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND ST A TE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THA T MAIN POWER SUPPL Y IS DISCONNECTED. THE APPLIANCE, WHEN INST ALLED, MUST BE ELECTRICALL Y GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, [...]

  • Page 27

    Page 27 20101-0-0306 SER VICE NOTES[...]

  • Page 28

    Page 28 20101-0-0306 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com[...]