Go to page of
Similar user manuals
-
Switch
Enterasys Networks RBT-1002-EU
28 pages 0.48 mb -
Switch
Enterasys Networks 2000
188 pages 1.73 mb -
Switch
Enterasys Networks 700
182 pages 1.71 mb -
Switch
Enterasys Networks G3G124-24P
59 pages 2.15 mb -
Switch
Enterasys Networks RBT-8110
36 pages 0.91 mb -
Switch
Enterasys Networks 7KR4297-04
64 pages 1.67 mb -
Switch
Enterasys Networks C2K122-24
70 pages 1.28 mb -
Switch
Enterasys Networks G3G170-24
59 pages 2.15 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Enterasys Networks C1H124-24, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enterasys Networks C1H124-24 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Enterasys Networks C1H124-24. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Enterasys Networks C1H124-24 should contain:
- informations concerning technical data of Enterasys Networks C1H124-24
- name of the manufacturer and a year of construction of the Enterasys Networks C1H124-24 item
- rules of operation, control and maintenance of the Enterasys Networks C1H124-24 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enterasys Networks C1H124-24 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enterasys Networks C1H124-24, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enterasys Networks service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enterasys Networks C1H124-24.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Enterasys Networks C1H124-24 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CPU RPS 1 16 17 32 33 48 49 51 2345678 9 10 1 1 12 13 14 15 18 19 20 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38 39 40 41 42 43 44 45 46 47 50 52 1 2 47 48 52 50 49 51 C1H124-48 CPU RPS 11 12 13 14 21 22 23 24 1 2 23 24 CONSOLE C1G124-24 9033831-04 Matrix C1 Series Ethernet Switc hes ( C1G124-24 and C1H124-48 ) Installation Guide[...]
-
Page 2
[...]
-
Page 3
NOTICE Enterasys Networks reserv es the right to mak e changes in specif ications and other informati on contained in this document and its web site without p rior not ice. The reader should in all cases c onsult Enterasys Networks to determine whether any such changes ha v e been made. The hardware, fi rmware, or softwa re described in th is docum[...]
-
Page 4
FCC NOTICE This device complies with P art 15 of th e FCC rules. Operation is subject to th e follo wing two conditions: (1) this device may not cause harmful in terferen ce, and (2) this de vice must accept an y interference recei v ed, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to com[...]
-
Page 5
SAFETY COMPLIANCE Warning: Fiber-optic Port Safety When using a fiber -optic media expansion module , ne ver look at the transmit laser while it is powered on. Also, ne ver look directly at the fibe r TX port and f iber cable ends when they are powered on. Avertissment: Ports pou r fibre s optiques - sécurité sur le plan optique Ne regarde z jama[...]
-
Page 6
Wichtige Siche rheitshinw eise (Germa ny) 1. Bitte lesen Sie diese Hi n weise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom St romnetz zu trennen. Verwenden Sie ke ine Flüssigoder Aerosolreiniger. Am besten eignet sich ein angefe uchtetes Tuch zur Reinigung. 4. Die Netzans[...]
-
Page 7
ENTERASYS NETWORKS, INC. PROGRAM LICEN SE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT , CAREFULL Y READ THIS LICENSE A GREEMENT . This document is an agree me nt (“ Agreement”) between the e nd user (“Y ou”) and Enterasys Networks, Inc. on behalf of itself and its Af filiates (a s hereinafter de fined) (“Enterasys”) that [...]
-
Page 8
3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts of the Commonwealth of Massachusetts without reg ard to its conflicts of laws provisions. You ac cept the personal jurisdiction and venue of the Commonwea lth of Massachusett s courts. None of the 1980 United Nations Convention on [...]
-
Page 9
8. AUDIT RIGHTS. You hereby acknowledge that the in tellectual prope rty rights associated w ith the Pr ogram are of critical value to Enterasys and, accordingly, Yo u hereby agree to maintain comp lete books, records and accounts showing (i) license fees due and paid, and (ii) the use, copying and deployment of the Pr ogram. You also grant to Ente[...]
-
Page 10
DECLARATION OF CONFORMITY Application of Coun cil Directi ve(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Enterasys Networks, Inc. Manufacturer’ s Address: 50 Minuteman Road Andover, MA 01810 USA European Representati v e Address: Enterasys Networks Ltd. Nexus House, Newbury Business Park London Road, Newbury Berkshire RG14 2PZ, England Confor[...]
-
Page 11
Contents ix Contents Figures ......... ................. ............ ................. ................ ............. ................ ................ .......... .............. xi Tables..... ................ ................ ............. ................ ................ ................. ............. ......... ... ................. xii ABOUT [...]
-
Page 12
x Contents 3.3 Installing Optional Mini-GBICs .. ................ .................... ................ ................ .. 3-2 3.4 Installing the Device ........ ................. ................ ................ ................ ............... 3-5 3.4.1 Rackmount I nstallation ........ ................ ............. ................ ...........[...]
-
Page 13
Figures xi Figure Pa g e Figures 1-1 C1H124-48 Stand a lon e De vice ..... ............. ... ... ... ... .... ............. ... ... ... .... ............ .... ... ... ... .. 1-2 1-2 C1G124-24 Stan dalone Devic e ........ ............. ................ ................ ................ ............. ..... 1-3 3-1 Mini-GBIC with MT-RJ Connect or (C1H[...]
-
Page 14
xii Ta b l e s Ta b l e Pa g e Ta b l e s 3-1 Contents of Shipping Car ton ................... ............. ................ ................ ............. ............3-2 4-1 LANVIEW LE Ds ...... ................ ................ ................ ................ ............. ................ .........4-2 4-2 Troublesho oting Check list ....... [...]
-
Page 15
About This Guide xiii About This Guide This guide provides information necessary to install and set up the Matrix C1 Series C1H124-48 and C1G124-24 devices and av ailable options. For information about the Command Line Interface (CLI) set of commands used to conf igure and and manage the C1H 12 4-4 8 and C1G124-24, refer to the Enterasys Networks?[...]
-
Page 16
Structure of This Guide xiv About This Guide STRUCTURE OF THIS GUIDE This guide is or ganized as follo ws: This preface pro vides preliminar y information to help you use this guide an d a brief summary of each chapter , defines con ventions used in this document, and lists technology and user guides that may help you set up and manage the C1H124-4[...]
-
Page 17
How to Use This Guide About This Guide xv HOW TO USE THIS GUIDE RELATED DOCUMENTS The following documents can help you to set up and ma nag e the C1H124-48 and C1G124 -24: Matrix C Series Redundant P ower System Installation Guide Matrix C Series Configur ation Guide Cabling Guide The manuals listed abo ve can be obtained from the W orld W ide W eb[...]
-
Page 18
Document Con v entions xvi About This Guide DOCUMENT CON VENTIONS This guide uses the follo wing conv entions: NOTE: Calls the reader’ s attention to any ite m of inf ormation that may be of special impor t ance. TIP: Conv eys helpful hints concer ning procedure s or actions . CAUTION: Contains inf or mation essential to a v oid damage to the equ[...]
-
Page 19
Introduction 1-1 1 Intr oduction This chapter introduces the C1H124-4 8 and C1G124-24 standalone Ethernet switch de vices. 1.1 OVERVIEW The follo wing provides an o vervie w of the C1H124-48 and C1G124-24. C1H124-48 The C1H124-48 ( Figure 1-1 ) has se veral types of port connections, which include • forty-eight front panel RJ45 po rts (10B ASE-T/[...]
-
Page 20
C1G124-24 1-2 Introductio n Figure 1-1 C1H124-48 Standalone De vice C1G124-24 The C1G124-24 ( Figure 1-2 ) has se veral types of port connections, which include • twenty-four front panel RJ45 ports (10B ASE-T/100B ASE-TX/1000B ASE-T compliant), and • four e xpansion slots for optional Mini-GBIC interface modules. The 10/100/1000 Mb p s fix ed f[...]
-
Page 21
C1H124-48 and C1G124 -24 Introductio n 1-3 Figure 1-2 C1G124-24 St andalone De vice C1H124-48 and C1G124-24 The switch functions can be conf igured usin g the W ebV ie w™ applic ation, CLI switching commands, or SNMP . Each de vice can be installed as a tabletop unit or installed into a standard 19-inch rack using the mounting hardware supplied w[...]
-
Page 22
Po r t T r u n k i n g 1-4 Introductio n 1.3 P ORT T RUNKING Port T runking is used for load balancing or load sharing. Port T runking provides a m echanism to group, or aggregate, multipl e li nks of an y technology together to scale the backbone bandwidth beyond the limitations of a single link. All links are user-conf igurable so administrators [...]
-
Page 23
802.1p P or t Pr ior ity Introductio n 1-5 1.7 802.1p P OR T PRIORITY The 802.1p port priority is used to assig n a defa ult priority to the frames recei ved without priority information in their tag header , map prioritize d frames to the appropriate transmit queues, and prioritize frames according to protocol type. The 802.1p port prior ity is pa[...]
-
Page 24
UPN Suppor t 1-6 Introductio n 1.11 UPN SUPPORT User Personalized Networks (UPN) is an architect ure that allows net work administrators to map network services to identif ied users, machin es, peripherals and other network entities. UPN consists of three tiers: • Classification rules make up th e f irst or bottom tier . The rules apply to device[...]
-
Page 25
Getting Help Introductio n 1-7 1.12 GETTING HELP For addi tional support related to the de vices or this document, cont act En terasys Networks using one of the follo wing methods: Before contacting Enterasys Netw orks for technical support, have the following information ready: • Y our Enterasys Networks service contract number • A description[...]
-
Page 26
[...]
-
Page 27
Network Requirem ents 2-1 2 Netw ork Requirements Before installing the C1H1 24-48 and C1G124 -24, re view the requi rements and specif ications referred to the follo wing sections: • 10B ASE-T T wisted-Pair Network ( Section 2.1 ) • 100B ASE-TX T wisted-Pair Network ( Section 2.2 ) • 1000B ASE-FX Single-M ode and Multimode Fibe r-Optic Netwo[...]
-
Page 28
100BASE-TX T wisted-Pa ir Network 2-2 Network Requirements 2.2 100B ASE-TX T WISTED-PAIR NETW ORK When connecting a 100B ASE-TX segment to one of the f ixed ports (1 through 48), or to an optional Ethernet expansion mo dule, use Category 5 UTP cabli ng. The device at the other end of the twisted pair segment must meet IEEE 802.3-2002 100B ASE- TX F[...]
-
Page 29
Hardware Installation 3-1 3 Har dware Installation This chapter provides the instructio ns required to install the de vice. Follo w the order of the sections as listed belo w to correctly install the device. • Unpacking the device ( Section 3.2 ) • Installing options ( Section 3.3 ) • Installing the de vice (on a shelf or ta bletop, or into a[...]
-
Page 30
Unpacking the De vice 3-2 Hardware Installation 3.2 UNPAC KING THE DE VICE Unpack the de vice as follo ws: 1. Open the box and remove the packing material protecting the de vice. 2. Verify the contents of the carton as listed in Table 3-1 . 3. Remove the tape seal on the non- conductive bag to remove the de vice. 4. Perform a visual inspectio n of [...]
-
Page 31
Installing Op tional Mini-GBICs Hardware Installation 3-3 T o prepare and install a Mini-GBIC, proceed as follo ws: Preparation Before installing the Mini-G BIC, pro ceed as follo ws: 1. Attach the antistatic wrist strap (refer to the instructions in th e antistatic wrist strap package) before removing the Mini-GBI C from the antistatic packaging. [...]
-
Page 32
Installing Optional Mini-GBICs 3-4 Hardware Installation Figure 3-2 Mini-GBIC with LC Connector (C1 H124-48 shown) Removing the Mini-GBIC T o remov e a Mini-GBIC from the C1H124-48 port slot, proceed as follo ws: 1. Attach the antistatic wrist strap (refer to the inst ructions in the antistatic wrist strap package) before removing the Mini-GBIC. 2.[...]
-
Page 33
Installing the Device Hardware Installation 3-5 4. Grasp the sides of the Mini-GBIC and pull it straight out of the port slot . If storing or shipping the Mini-GBIC, insert the dust protector into the Mini-GBIC to protect the fiber ports. 3.4 INSTALLING THE DEVICE For a tabletop or shelf installation, locate the de vice within sev en feet of its po[...]
-
Page 34
Installing the De vice 3-6 Hardware Installation 3.4.1 Rac kmount Installation T o install the de vice in a 19-inch rack, you need: • T wo rackmount brack ets and mounting scre ws (rackmount kit) shipped with th e de vice. • Four user -supplied scre ws to attach the de vice to a standard 19-inch rack. 3.4.1.1 Guidelines f or Rac kmount Installa[...]
-
Page 35
Installing the Device Hardware Installation 3-7 2. With the mounting brackets attached, position the de vice betwee n the vertical frame members of the 19-inch rack as shown in Figure 3-5 . Then fasten the device securely to the frame using four mounting screws (user supplied). Figure 3-5 Fas te ning the De vice to the Rac k 3.4.3 Connecting P ower[...]
-
Page 36
Connecting to the Networ k 3-8 Hardware Installation Figure 3-6 Device, Rear View 3. Observe that the power (RPS) LED (not shown), located on the front pa nel, turns ON (green) and the CPU turns red until the de vi ce completes its initialization. It takes under 30 seconds for the device to boot up . 4. If you are installing an optional redunda nt [...]
-
Page 37
Connecting to th e Netw ork Hardware Installation 3-9 3.5.1 Connecting UTP Cables The RJ45 fix ed front panel ports (1 through 48) of the C1 H12 4-48 are 10B ASE-T/100B ASE-TX compliant and ha ve internal crossov ers. The RJ45 fix ed front panel ports (1 through 24) of the C1G124-24 are 10BASE-T/100B ASE-TX/1000BASE-T compliant and ha ve internal c[...]
-
Page 38
Connecting to the Networ k 3-10 Hardware Installation 3. Verify that a link exists by checking that the Link/Activity LED is ON (solid green or blinking green). If the Link/Act ivity LED is OFF, perform th e following steps until it is on: a. Verify that the cabling being us ed is Category 5 or better with an impedance between 85 and 111 ohms with [...]
-
Page 39
Connecting to th e Netw ork Hardware Installation 3-11 Figure 3-9 Four -Wire Straight-Thr ough Cable RJ45 Pinouts f or 10/100BASE-TX Figure 3-10 Eight-W ire Cr osso ver Cabl e RJ45 Pinouts f or 10/100/1 00 0B ASE-T RJ45 device por t RJ45-to-RJ45 straight-through cable Other de vice port RX+/RX- and TX+/TX- connections. These connections must share [...]
-
Page 40
Connecting to the Networ k 3-12 Hardware Installation Figure 3-11 Eight-Wire Str aight -Thr ough Cable RJ45 Pinouts f or 10/100/1000B ASE-T 3.5.2 Connecting Fiber -Optic Cables to MT -RJ P or ts This section contains the procedures for connecting a 1000B ASE-S X multimode f iber -optic segment fro m the network or other de vices to an MT -RJ port c[...]
-
Page 41
Connecting to th e Netw ork Hardware Installation 3-13 T o connec t an MT -RJ cable to a f ixed MT -RJ connector of a Mini-GBIC, refer to Figure 3-12 and proceed as follows: 1. Remove the protective covers (not shown) from the front panel MT-RJ fiber-optic port (port 52 in this example) and from the connectors on e ach end of the cabl e. 2. Insert [...]
-
Page 42
Connecting to the Networ k 3-14 Hardware Installation 3. Plug the other end of the cable into the approp riate port on the other device. Some cables may be terminated at the other end with two separate connectors, on e for each fiber-opti c strand. In this case, ensure that the tran smit fiber-optic strand is connecte d to the receive port an d the[...]
-
Page 43
Connecting to th e Netw ork Hardware Installation 3-15 Enterasys Networks recommends la beling fiber-optic cables to in dicate rece i v e and tra nsmit ends. Many cables are pre-labeled, providing matching labels or tapes at both ends of eac h strand of cable. T o connect an LC cable connector to a fix ed LC connector of a Mini-GBIC, refer to Figur[...]
-
Page 44
Connecting to the Networ k 3-16 Hardware Installation Figure 3-13 Cab le Connection to LC Multimode Fibe r- Opt ic Connector s 3. Plug the other end of the cable into the approp riate port on the other device. Some cables may be terminated at the other end with two separate connectors, on e for each fiber-opti c strand. In this case, ensure that th[...]
-
Page 45
Connecting to Console P or t for Local Ma nagement Hardware Installation 3-17 3.6 CONNECTING TO CONSOLE P OR T FO R LOCAL MANAGEMENT This section describes ho w to install a UTP st raight-through cable w ith RJ45 connectors and optional adapters to connect a PC, a VT series terminal, or a modem to an Enterasys Networks module to access CLI commands[...]
-
Page 46
Connecting to Conso l e P or t for Lo cal Management 3-18 Hardware Installation 4. Turn on the PC and co nfigure your VT emul ation package with the following parameters: When these parameters are set, the Startup screen will display . Proceed to Section 3.7 to complete the installation. Figure 3-14 Connecting an IBM PC or Compatible 3.6.3 Connecti[...]
-
Page 47
Connecting to Console P or t for Local Ma nagement Hardware Installation 3-19 4. Turn on the terminal and acces s the Setup Directory. Set the following pa rameters on your terminal: When these parameters are set, the Star tup screen w ill display . Proceed to Section 3 .7 to complete the installation. Figure 3-15 Connectin g a VT Series T erminal [...]
-
Page 48
Connecting to Conso l e P or t for Lo cal Management 3-20 Hardware Installation 5. Configure your VT emulation packag e with the following parameters: When these parameters are set, the Startup screen will display . Proceed to Section 3.7 to complete the installation. Figure 3-16 Connect ing to a Modem Par a m e t er Setting Mode 7 Bit Control T ra[...]
-
Page 49
Connecting to Console P or t for Local Ma nagement Hardware Installation 3-21 3.6.5 Adapter Wiring and Signal Assignments Console P ort Adapter Wiring and Signal Diagram RJ45 DB9 Pin Conductor Pin Signal 1 Blue 2 Receiv e (RX) 4 Red 3 T ransmit (TX) 5 Green 5 Ground (GRD) 2 Orange 7 Reques t to Send (R TS) 6 Y ellow 8 Clear to Send (CTS) VT Series [...]
-
Page 50
Connecting to Conso l e P or t for Lo cal Management 3-22 Hardware Installation Modem P or t Adapter Wiring and Signal Diagram RJ45 DB25 Pin Conductor Pin Signal 1 Blue 2 T ransmit (TX) 2 Orange 8 Data Carrier Detect (DCD) 4 Red 3 Rece i v e 5 Green 7 Ground (GRD) 6 Y ellow 20 Data T erminal Ready (DTR) 8 Gray 22 Ring Indicator RJ45 Connector (Fema[...]
-
Page 51
Completing t he I nstallation Hardware Installation 3-23 3.7 COMPLETING THE INSTALLATION After installing the Enterasys Networks de vice and making the connectio ns to the network, proceed as follows: Initial Logon to De vice Management T o initially access device management from your lo ca l pc, terminal, or mo dem connecti on, proceed as follo ws[...]
-
Page 52
[...]
-
Page 53
T roub leshooting 4-1 4 T roub leshooting This chapter provides information concerning the follo wing: • Using LANVIEW ( Section 4.1 ) • T roubleshooting checklist ( Section 4.2 ) • Using the Reset b utton ( Section 4.3 ) 4.1 USING LANVIEW The C1H124-48 (sho wn in Figure 4-1 ) and the C1G124-24 use the En terasys Networks built-in visual diag[...]
-
Page 54
Using LANVIEW 4-2 T roub leshooting NOTE: The terms flashing , blinking , and solid used in Ta b l e 4 - 1 indicate the f ollowing: Flashing: LED is flashing ran domly . Blinking: LED is flashing at a steady rate (approximately 50% on, 50% of f). Solid: LED is on steady and not pulsing. T able 4-1 LANVIEW LEDs LED Color State Recomme nded Action CP[...]
-
Page 55
Using LANVIEW T roub leshooting 4-3 RPS Off No po wer indicated by either the internal or a connected external po wer supply , or there is no po wer redundancy a vailable from the external po wer supply . 1. Ensure that the power cords are plugged in correctly and that there is power at the two power sources. 2. If an external power supply is conne[...]
-
Page 56
T rouble shooting Chec klist 4-4 T roub leshooting 4.2 T ROUBLESHOOTING CHEC KLIST If the device is not working properly , refer to Ta b l e 4 - 2 for a checklist of problems, possible causes, and recommended actions to resolve the problem. T able 4-2 T roublesh oot ing Chec klist Prob lem Possible Cause Recommended Action All LEDs are OFF . Loss o[...]
-
Page 57
T roubl eshooting Chec klist T roub leshooting 4-5 Cannot contact the device through in-band managemen t. IP address not assigned. R efer to the Matrix C Series Configur ation Guide for the IP address assignment procedure. Port is disabled. Enable port. Refer to the Mat rix C Series Conf igur ation Guide for instructions to enable/disable ports. No[...]
-
Page 58
Using the Rese t Button 4-6 T roub leshooting 4.3 USING THE RESET BUTTON If you forget the password to the de vice manageme nt entity , you can use the Reset button sho wn in Figure 4-1 to reset the device management password. Figure 4-2 Reset Butt on T o reset the device passw o rd, proceed as follows: 1. Make sure that the CPU LED is solid green,[...]
-
Page 59
Specifications A-1 A Specifications This appendix provides info rmati on about the follo wing: • C1G124-24 and C1H124 -4 8 specifications ( Section A.1 ) • Optional Mini-GBIC inpu t/output port specif ications ( Section A.2 ) • Gigabit Ethernet ( Section A.3 ) • Console Port pinout assignment ( Section A.4 ) • Regulato ry compliance ( Sec[...]
-
Page 60
C1G124-24 and C1 H124-48 Specificat ions A-2 Specifications A.1 C1G124-24 AND C1H 124-48 SPECIFICATIONS Ta b l e A - 1 provides th e I/O ports, processors and memory , physical, and en vironmenta l specif ications for the C1 G124-24 and C1H124-48. Table A-1 Device Specif ications Item Specification C1G124-24 I/O P o rts Ports 1 through 24 (21 throu[...]
-
Page 61
C1G124-24 and C1 H124-48 Specifica tions Specifications A-3 Redundant Po wer Source Connector External Po wer Connector on rear of the C1G124-24 and C1 H124-48 15-pin D-type connector for an optional dc Po wer/Monitor cable conn ection from an external redundant po wer supply module (CSER-RPS-PSM). Physical Dimensions 8.9H x 44.45W x 44.0D (cm) 3.5[...]
-
Page 62
Mini-GBIC Input/ Ou tput Specificat ions A-4 Specifications A.2 MINI-GBIC INPUT/OUTPUT SPECIFICATIONS The Mini-Gigabit Ethernet Card (Mini-GBIC) port expansion slots can ac cept 1000BASE-SX short wavelength or 1000BASE-LX long wav ele ngth fiber-optic Mini-GBICs (refer to Ta b l e A - 2 ). The optional Mini-GBICs are hot swappable. A.3 GIGABIT ETHE[...]
-
Page 63
Gigabit Ethernet Specifications Specifications A-5 A.3.2 MGBIC-LC09 Specif ications (1000B ASE-LX) Table A-4 MGBIC-LC01 / MG BIC-MT 01 O perating Range Item Modal Ba ndwidt h @ 850 nm Range 62.5 µm MMF 160 MHz/km 2-220 Meters 62.5 µm MMF 200 MHz/km 2-275 Meters 50 µm MMF 400 MHz/km 2-500 Meters 50 µm MMF 500 MHz/km 2-550 Meters Table A-5 MGBIC-[...]
-
Page 64
Console P or t Pinout Assignments A-6 Specifications A.4 CONSOLE P OR T PINOUT ASSIGNMENTS The Console port is a serial communications port that supports local mana gement of the C1H124-48 and C1G124-24 . These pin assignments d if fer from other Enterasys products. Refer to Ta b l e A - 7 for the Console po rt pin assignments. A.5 REGULATORY COMPL[...]