Go to page of
Similar user manuals
-
Stove
Enviro 50-1573
13 pages 1.22 mb -
Stove
Enviro Cara
44 pages 4.16 mb -
Stove
Enviro C-11256
16 pages 0.89 mb -
Indoor Fireplace
Enviro EG.95.FPI.BV.LPG
16 pages 2.69 mb -
Stove
Enviro EG40 DV
33 pages 2.09 mb -
Indoor Fireplace
Enviro C-11275
42 pages 3.22 mb -
Indoor Fireplace
Enviro 50-927
35 pages 2.44 mb -
Stove
Enviro Meridian C-10135
38 pages 3.02 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Enviro 170S5FG, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enviro 170S5FG one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Enviro 170S5FG. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Enviro 170S5FG should contain:
- informations concerning technical data of Enviro 170S5FG
- name of the manufacturer and a year of construction of the Enviro 170S5FG item
- rules of operation, control and maintenance of the Enviro 170S5FG item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enviro 170S5FG alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enviro 170S5FG, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enviro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enviro 170S5FG.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Enviro 170S5FG item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
[...]
-
Page 2
MQL • T ABLE OF C ONTENTS 2 Product Overview .....................................................................................................................................3 Features and Benefits ...............................................................................................................................6 Application Consi[...]
-
Page 3
P RODUCT O VERVIEW • MQL 3 The Perfect Solution for Schools, Hospitals, and Commercial Buildings. The flexibility of the Model MQL Blower Coil allows you to design the unit to meet the specific project needs. The MQL design allows you to configure draw thru applications in horizontal, vertical, and foot- print-saving arrangements. From basic air [...]
-
Page 4
MQL • F EA TURES AND B ENEFITS 4 Designed For Maximum Flexibility The ENVIRO-TEC ® Model MQL Blower Coil Unit is designed to maximize flexibility of selection and installation. The unit is also designed to exceed the stringent quality standards of the institutional market, while remaining cost competitive in the light commercial segment of the m[...]
-
Page 5
A PPLICA TION C ONSIDERA TIONS • MQL 5 Application Considerations Model MQL blower coil units offer a wide range of application flex- ibility , while maintaining a simple, easy to install unit design. These units are intended to provide comfort cooling and heating within a small footprint. They may be applied in many types of building structures [...]
-
Page 6
MQL • U NIT C ONFIGURA TION 6 Pos ition: 1 2 3 45 6 7 8 9 1 0 M QL - Modul e Si z e Dim . 02 03 04 06 08 10 12 14 17 H - in ( m m ) 17-3/ 8 (441) 17-3/ 8 (441) 17-3/ 8 (441) 26-3/ 8 (670) 26-3/8 ( 670) 26-3/ 8 (670) 41- 3/16 ( 1046) 41-3/ 16 (1046) 41-3/ 16 (1046) W - in (mm ) 28 (711) 34 (864) 42 (1069) 42 (1069) 46 (1168) 56 (1422) 64 (1626) 68[...]
-
Page 7
E LECTRIC H EA T • MQL 7 ST ANDARD FEA TURES • G60 galvanized steel casing • Flanged construction for direct unit mounting, in blow thru configuration • Listed for zero clearance installation • Meets National Electrical Code requirements • Ni-Chrome wire in ceramic insulators • Stainless steel element terminals and hardware • Elemen[...]
-
Page 8
MQL • E LECTRIC H EA T 8 Notes: 1. Blow thru heaters can have a maximum of two stages. 2. VFD controllers cannot be supplied with blow thru heaters. 3. Specific kW ratings are available within the ranges shown. Refer to selection program. 4. Heaters above 480v must utilize one time secondary limits only . Notes: 1. Draw thru heaters can have a ma[...]
-
Page 9
C OIL AND F IL TER D ATA • MQL 9 ENVIRO-TEC ® offers hot water , chilled water , direct expansion (DX), and standard steam coils for specific application with all Model MQL blower coils. Coils tested in accordance with ARI 410, and strict on-site inspection before, during, and after installation guarantees the highest quality and performance ava[...]
-
Page 10
MQL • S T A TIC P RESSURE D ATA 10 Mi x i ng Bo x E cono- mizer Filt e r Modul e s Acce s s Modul e s Pl e num Modul e E cono- mizer Bl o w Thru Dra w Thru 600 0. 01 0. 02 0. 01 0. 01 0. 02 0. 02 0. 02 0. 02 0. 02 0. 04 0. 02 0. 04 0. 02 0. 01 850 0. 02 0. 04 0. 02 0. 02 0. 03 0. 03 0. 04 0. 03 0. 04 0. 06 0. 04 0. 07 0. 04 0. 01 975 0. 02 0. 04 [...]
-
Page 11
S T A TIC P RESSURE D ATA • MQL 11 Filt e r Size & Typ e E ffi ci e n cy 200 250 300 350 400 450 500 550 600 650 700 750 800 2" @ 30% 0. 12 0. 15 0. 18 0. 21 0. 24 0. 27 0. 30 0. 33 0. 36 0. 39 0. 42 0. 45 0. 48 4" @ 65% 0. 18 0. 23 0. 27 0. 32 0. 36 0. 41 0. 45 0. 50 0. 54 0. 59 0. 63 0. 68 0. 72 4" @ 85% 0. 26 0. 33 0. 39 0. [...]
-
Page 12
Coil W eight Data 8 FP I 10 FP I 12 FP I 14 FP I 8 FP I 10 F P I 12 FP I 14 F P I 8 FP I 10 F P I 12 F P I 14 F P I 1 10 [5] 11 [5] 11 [5] 11 [5] 12 [5] 12 [5] 13 [6] 13 [ 6] 12 [5] 12 [5] 13 [6] 13 [6] 2 16 [7] 16 [7] 17 [8] 18 [8] 19 [9] 20 [9] 21 [10] 21 [10] 20 [ 9] 20 [9] 21 [10] 22 [10] 3 21 [10] 22 [10] 23 [11] 24 [ 11] 27 [12] 28 [13] 29 [1[...]
-
Page 13
W EIGHT AND E LECTRICAL D ATA • MQL 13 Motor Electrical Data NOTES: 1. Actual motor nameplate AMPs may vary , but will not exceed values shown. 2. Consult factory for applications requiring special motors. 115/1 208/1 230/1 277/ 1 208/3 230/3 460/3 575/ 3 1/ 3 6. 3 3. 5 3. 2 2. 6 1. 7 1. 5 0. 8 - 1/ 2 7. 8 4. 3 3. 9 3. 6 2. 2 2. 1 1. 1 0. 9 3/ 4 [...]
-
Page 14
MQL • F AN P ERFORMANCE D ATA 14 F or ward Cur ved F an P erformance Data TS P UN I T SI ZE (in- w g) Ac tu a l C FM 650 750 850 950 1050 950 1100 1250 1400 1550 1200 1400 1600 1800 2000 RP M –––––––––––––– 1793 BHP –––––––––––––– 1 . 9 9 RP M ––––––––– 1913 –––– 16[...]
-
Page 15
F AN P ERFORMANCE D ATA • MQL 15 Plug F an P erformance Data TS P UNIT SIZ E ( i n-w g) Actual CFM 450 650 850 1050 1250 650 900 1150 1400 1650 800 1150 1500 1850 2200 RP M 2870 2881 2950 3068 3246 2869 2877 2931 3017 3170 2868 2890 2974 3122 3318 BHP 0. 92 1. 08 1. 24 1. 42 1. 65 1. 32 1. 52 1. 71 1. 92 2. 20 1. 58 1. 85 2. 13 2. 48 2. 91 RP M 2[...]
-
Page 16
MQL • F AN P ERFORMANCE C URVES 16 MQL02 (F an 09-04 Class I) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 CFM STATIC PRESSURE - INCHES WATER GAUGE 1/3 HP 1/2 HP 1 HP 600 800 1000 1200 1400 1600 1800 2000 2200 RPM 3/4 HP 1.5 HP 2 HP MQL03 (F an 09-06 Class I) 0.0 0.5 1.0 1.5 2.0 2.[...]
-
Page 17
F AN P ERFORMANCE C URVES • MQL 17 MQL06 (F an 12-09 Class I) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 CFM STATIC PRESSURE - INCHES WATER GAUGE 600 800 1000 1200 1400 RPM 1/2 HP 3/4 HP 1 HP 1.5 HP 3 HP 400 2 HP MQL04 (F an 10-07 Class I) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 1100 1200 1300 1400[...]
-
Page 18
MQL • F AN P ERFORMANCE C URVES 18 MQL08 (F an 12-12 Class I) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 CFM STATIC PRESSURE - INCHES WATER GAUGE 600 800 1000 1200 1400 RPM 3 HP 1/2 HP 3/4 HP 1 HP 1.5 HP 5 HP 2 HP MQL10 (F an 15-11 Class I and II) 0.0 0.5 1.0 1.5 2[...]
-
Page 19
F AN P ERFORMANCE C URVES • MQL 19 MQL12 (F an 18-13 Class I and II) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 CFM STATIC PRESSURE - INCHES WATER GAUGE 600 1000 RPM 1 HP 1.5 HP 2 HP 3 HP 5 HP 7.5 HP 400 800 CLASS I CLASS II SE = CFM x SP 6362 x BHP MQL14 (F an 18-18 Class I and II) 0.0 0.5 1.0[...]
-
Page 20
MQL • F AN P ERFORMANCE C URVES 20 MQL17 (F an 18-18 Class I and II) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000 9500 10000 10500 11000 11500 12000 12500 13000 CFM STATIC PRESSURE - INCHES WATER GAUGE 600 800 1000 RPM 10 HP 1.5 HP 15 HP 7.5 HP 5 HP 3 HP 2 HP 400 CLASS I CLASS II SE = CFM x SP 6362 x [...]
-
Page 21
F AN P ERFORMANCE C URVES • MQL 21 MQL03 Plug F an 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 0 200 400 600 800 1000 1200 1400 1600 1800 CFM STATIC PRESSURE - INCHES WATER GAUGE 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 1/3 HP 1/2 HP 3/4 HP 1 HP 3000 RPM 1.5 HP 2 HP MQL04 Plug F an 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 [...]
-
Page 22
MQL • F AN P ERFORMANCE C URVES 22 MQL06 Plug F an 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 CFM STATIC PRESSURE - INCHES WATER GAUGE 600 800 1000 1200 1400 1600 1800 2000 2200 RPM 1/3 HP 1/2 HP 3/4 HP 1 HP 1.5 HP 3 HP 400 2 HP MQL08 Plug F an 0.0 0.5 1.0 1.5[...]
-
Page 23
F AN P ERFORMANCE C URVES • MQL 23 MQL10 Plug F an 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 CFM STATIC PRESSURE - INCHES WATER GAUGE 600 800 1000 1200 1400 1600 1800 RPM 1.5 HP 1 HP 3/4 HP 1/2 HP 1/3 HP 7.5 HP 5 HP 3 HP 2 HP 400 MQL12 Plug F an 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0[...]
-
Page 24
MQL • F AN P ERFORMANCE C URVES 24 MQL14 Plug F an 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000 CFM STATIC PRESSURE - INCHES WATER GAUGE 600 800 1000 1200 1400 1600 RPM 7.5 HP 1/3 HP 1/2 HP 3/4 HP 1 HP 1.5 HP 2 HP 400 10 HP 1800 RPM 5 HP 3 HP MQL17 Plug [...]
-
Page 25
G UIDE S PECIFICA TIONS • MQL 25 Guide Specifications Blower Coil Unit HV AC Guide S pecifications - Section 15XXX Size Range: 600 – 10,000 CFM ENVIRO-TEC ® Model Number: MQL Part 1 — General 1.01 SYSTEM DESCRIPTION A. Indoor mounted blower coil unit designed to provide air to a conditioned space as required to meet specified performance req[...]
-
Page 26
MQL • G UIDE S PECIFICA TIONS 26 2.0 Fan decks shall be internally spring isolated (one-inch deflection) with the fan outlet connection to be made using canvas duct. 3.0 Each unit shall have one fan wheel and housing only . 4.0 Fan wheels shall be designed for continuous operation at the maximum rated fan speed and motor horsepower . Fan wheels a[...]
-
Page 27
G UIDE S PECIFICA TIONS • MQL 27 H. S pecial Features: The following unit options shall be available. 1.0 Fan Section: a. V ariable frequency drives. b. Motor starters – cont actor with overload for three phase and contactor for single phase. c. High-efficiency motors (inverter-duty). d. T otally enclosed fan cooled (TEFC) motors (inverter-duty[...]
-
Page 28
MQL • M ETRIC C ONVERSION 28 S I UNI T CONV ERSI ON F ACTO R = ENGL I S H UNI T CONV ERSI ON F ACTO R = SI UNI T S I UNI T CONV ERSI ON F ACTO R = E N GL ISH UNI T CONV ERSI ON F ACTO R = SI UNI T cm 2 100 mm 2 °C 1. 8 °F 0. 5556 °C cm 2 0.1550 in 2 645. 2 mm 2 m 2 10. 76 ft 2 0. 09290 m 2 m / s 3. 281 ft / s 0. 3048 m/ s m/ s 196. 9 ft/ m i n[...]
-
Page 29
NOTES 29 ENVIRO-TEC[...]
-
Page 30
ST ANDARD FEATURES Construction • Modular design facilitates retrofit • Galvanized steel cabinet construction • 1" thick fiberglass insulation, glued and pinned in place • Gasketed, removable access panels sized for easy handling • Left and right hand arrangement • Access panels on all sections Fan Assembly • Single forward-curve[...]