A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Enviro 828 DV.FS., along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enviro 828 DV.FS. one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Enviro 828 DV.FS.. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Enviro 828 DV.FS. should contain:
- informations concerning technical data of Enviro 828 DV.FS.
- name of the manufacturer and a year of construction of the Enviro 828 DV.FS. item
- rules of operation, control and maintenance of the Enviro 828 DV.FS. item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enviro 828 DV.FS. alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enviro 828 DV.FS., and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enviro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enviro 828 DV.FS..
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Enviro 828 DV.FS. item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER 8 2 8 By SHERWOOD INDUSTRIES LTD. Direct Vent OWNERS MANUAL Installation And Operating Instructions For Models: 828 MH (MOBILE HOME) 828 DV. FS. (Freestanding) 828 DV. INS. (Insert) WARNING If the information in this manual is not followed exactly[...]
-
Page 2
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" ROOM HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • All "ENVIROGAS" gas-fired appliances must be installed in accordance with these instructions. Carefully read all the instructions in th is manual first. Consult the building authority havi[...]
-
Page 3
TABLE OF CONTENTS 1 Code A pproval s ............................................................................................................. ..............................3 S pecificat ions ........................................................................................................... ....................................3 2 Dimens[...]
-
Page 4
2 . DIMENSIONS AND CLEARANCES TO COMBUSTIBLES FIREPLACE INSERT: The stove can only be installed in a so lid fuel burning fireplace . Mantle pillar to stove 10” Stove top to 8” wide mantle 12” Minimum firebox size W 26” x H 20” x D 20” (NOTE; standard size shown – optional 33”H x 46”W available) FREESTANDING: Side wall to stove 10&[...]
-
Page 5
ZERO CLEARANCE BOX ASSEMBLY; First take the kit from the box and place the surround panels as ide so as not to damage the panels. There will also be a bag of screws, nuts and bolts in the box. The bottom section of the kit will have tw o 3 inch square boxes mounted to t he bottom. First attach the bottom to the back with the screw s provided, t he [...]
-
Page 6
3. DECIDING WHERE TO LOCATE YOUR STOVE FREESTANDING: • Locate the stove in a large and open room that is centrally located in the hous e. This will optimize heat circulation and comfort. • The stove should be located out of traffic, away from furniture and draperies and should have sufficient access for its safe operation and maintenance. • T[...]
-
Page 7
FIREPLACE INSERT • Carefully clean the fireplace and flue before in stalling the stove. Failure to do so ma y result in fumes or dirt being blown i nto the room or insert and may cause a fire leading to death or serious injury. • If you are installing the optional fan ki t, (see Installing Fan Kit) do so now . • If the fireplace has a dropped[...]
-
Page 8
5. INSTALLING BURNER CONTROL ASSEMBLY Remove the controls from box, che ck for shipping damage. Remove burner tray from controls (one scr ew on each side between burners). Open door. Remove grate rod by pu lling up at each end. Remove the 2 screws behind the grate and one screw on each side of control opening in firebox. Extend flex gas line and pl[...]
-
Page 9
2. Place the log with Burnt Area forward on log supports. Locate the log by matching the bottom pegs to the receiving holes in rear log supports. 3. Close door securely 7. ELECTRICAL REQUIREMENTS T he ENVIROGAS 828 Series w ill operate wit hout an external electrical pow er supply. This model has a Millivolt gas control which uses the pilot flame t[...]
-
Page 10
8. GAS LINE CONNECTION AND TESTING WA RNING: Only persons licensed to w ork w ith gas piping can make the gas connections to this appliance. This appliance is equipped with a 3/8” stainless steel flex line from the valve. This line ma y be routed through the hole in the rear of the pedestal, or on inserts, routed through the fire box sides. An ad[...]
-
Page 11
9. AIR SHUTTER ADJUSTMENT • There is a separate venturi air shutter for each burner • The venturies have been set for installation at sea level to 4,500 ft. • To adjust for higher altitudes : Remove the access cover plate, loosen the air shutter locking screws w ith a long screw driver. Rotate the air shutters to the correct setting. The flam[...]
-
Page 12
10. VENTING VENT TERMINATION CLEARANCES A= Clearance above grade, ve randah, porch, deck, or [balcony (*12 inches (30cm) minimum] B= Clearance to window or door that may be opened [*12 inches (30cm) minimum] C= Clearance to permanently closed w indow [minimum 12 inches (30cm) recommended to prevent condensation on window ] D= Vertical clearance to [...]
-
Page 13
These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE "GS" PIPE FOR GAS STOVE. Kits are available for vertical venting or horizontal ve nting. It is recommended that a bead of RTV High Temperature Silicone be applied to each vent joint before installation. A MINIMUM VERTICAL LENGTH OF 24" TO THE F[...]
-
Page 14
When planning your installation, it w ill be necessary to select the proper length of vent pipe fo r y our particular requirements . It is important to note when passing thr ough a wall, the max imum allowable w all thickness is 10-inches (254mm), 1 ½ inches clearance to combustibles must be maintained. Select the amount of vertical rise desired f[...]
-
Page 15
STEP 7. Slide the decorative wall thimble up to the wall su rface and attach with the screws provided. Apply decorative brass or chrome trim if desired. FIG-14. FIG. 11 FIG. 12 FIG-13 FIG-14 NOTES: (1) The four wood screws provided should be replaced with th e appropriate fasteners for stucco, brick, concrete, or other types of siding. (2) For buil[...]
-
Page 16
VERTICAL INSTALLATION STEP 1. Check the instructions for required clearances (air spaces) to combustibles w hen passing through ceilings, walls, roofs, enclosures, attic rafters , or other nearby combustibl e surfaces. Do not pack air spaces w ith insulation. STEP 2. Set the gas appliance in the desired loca tion. Drop a plumb bob dow n from the ce[...]
-
Page 17
NOTES: (1) If an offset is necessary in the attic to avoid obstruc tions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose. FIG- 18 (2) When ever possible, use 45 ° degree elbows instead of 90 ° degree elbows. The 45 ° degree elbow [...]
-
Page 18
CATHEDRAL CEILING INSTALLATION Step 1. Follow installation steps 1 and 2 under Vertical Termination. Step 2. Using the plumb bob, mark the centerline of the venting system on the ceiling and drill a small hole through the ceiling and roof at this point. From the roof, locate the drill hole and mark the outline of the Cathedral Ceiling Support Box. [...]
-
Page 19
11. MOBILE HOME FUEL CONVERSION To conve rt from Propane to Natural Gas or v ise-versa 1. Disconnect the unit from the gas supply. 2. Open the door and remove the logset. 3. Remove the burner tray (2 screw s) and the burner control assembly by removing the 8 screw s holding it into the unit. 4. Remove the control panel from the control assembly 5. [...]
-
Page 20
12. OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIO NS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot that must be lit by hand by following these instructions exactly. B) BEFORE LIGHTING smell al[...]
-
Page 21
13. MAINTENANCE AND TECHNICAL Periodically check to ensure that your "Direct Vent" sy stem is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue wi th small yellow tips. OPENING THE DOOR Caution door is hot w[...]
-
Page 22
14. TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of spark ignitor Defective piezo ignitor Check connections to ignitor -If ignitor connections are good but there is no spark-replace ignitor Broken spark electrode -Check for broken ceramic insulation replace, electrode if broken Mis-aligned [...]
-
Page 23
15. PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer. PA RT # DESCRIPTION 828-001 Convection Blower 828-002 Heyco Strain Relief 828-003 2-Speed Fan Switch 828-004 Eurosit Manually Regulated Valve, Natural Gas 828-005 Eurosit Manually Regulated Valve, Liquid Propane 828-006 Pilot with Ignitor Electrode, Natural Gas 828-[...]
-
Page 24
16. WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifet ime warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the lifetime warranty are Cabinet Sides, Tops, Pe destals, Surround Pane[...]
-
Page 25
17. INSTALLATION DATA SHEET The installer for warranty purposes and future re ference must record the following information. Envirogas Models: 828.DV. FS. (Freesta nding) Direct Vent Room Heater 828 DV. INS. (Insert) 828 DV. MH. (Mobile Home) N ame of Owner: __________________________________________ Address: _______________________________________[...]