Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Enviro C-10794, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enviro C-10794 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Enviro C-10794. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Enviro C-10794 should contain:
- informations concerning technical data of Enviro C-10794
- name of the manufacturer and a year of construction of the Enviro C-10794 item
- rules of operation, control and maintenance of the Enviro C-10794 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enviro C-10794 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enviro C-10794, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enviro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enviro C-10794.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Enviro C-10794 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE 50-1033 W e s t p o r t This appliance may be installed in an after-mark et permanently located, manufactured (mobile) home, where not proh[...]

  • Page 2

    2 FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst. Consult the building authority having jurisdiction to determine the nee[...]

  • Page 3

    T able of Contents 3 Safety Precautions.................................................................................. ...................2 T able of Contents......................................................................................................3 Codes And Approv als.................................................................[...]

  • Page 4

    4 DIRECT VENT ONLY: This type is identied by the sux DV . This appliance draws all of its air f or combustion from outside the dwelling, through a specially designed v ent pipe system. TOP VENT DV Certied for installation from 0-4500 ft (0-1372 m) REAR VENT DV Certied for installation from 0-4500 ft (0-1372 m) with 36” (915 mm) snorke[...]

  • Page 5

    5 Specific a tions WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. D IMENSIONS : 16 5 / 8 " (42.2cm) 25 " (65.3cm) 25 " (65.4cm) 27" (68.6cm) 25 " (65.3cm) 17 1 / 8 " (43.5cm) 15 "[...]

  • Page 6

    6 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P ILOT L IGHTING I NSTRUCTIONS : Figure 3. Lighting Instruction Label 1. Flip burner switch [...]

  • Page 7

    7 2. Start the pilot by pr essing the gas control knob and turning it to PILO T . While holding the gas control knob in, press the piezo ignitor sever al times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see Figure 4). 3. Start the main burner by turni[...]

  • Page 8

    8 Electronic ignition module Maintenance And Ser vice R OUTINE M AINTENANCE : At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the burner to see if all the ports ar e clear and clean. Check the pilot to make sure it is not blocked by anything. The pi lot ame should be blue wit[...]

  • Page 9

    Figure 7: Handles for Removing Door. Figure 8: Removing of Door. Maintenance And Ser vice R EPLACING THE G LASS : The glass in the replace is a high temperatur e ceramic. If the glass is damaged in any way , a factory replacement is required (see P ARTS L IST - C OMPONENTS ). W ear gloves when handling damaged glass door assembly to prevent pers[...]

  • Page 10

    Maintenance And Ser vice TO BE INST ALLED BY A QU ALIFIED SERVICE A GENCY ONL Y F UEL C ONVERSION : Warning: This conversion kit shall be installed by a qualied service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructio[...]

  • Page 11

    Step 8. Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood and reinstall the hood by placing the hood on the assembly , line up the key wa y , and snap into place. Step 9. Remo ve the main burner orice with a  inch deep socket. Step 10. Install the new orice supplied. Be su[...]

  • Page 12

    12 1 In accordance with the current CSA B149, Natur al Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFP A 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the r equirements of the gas supplier . t A vent shall not terminate directly above a side w [...]

  • Page 13

    13 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y V ENT P ARTS : This replace have been tested and certied for use with SIMPSON DURA VENT T YPE GS PIPE FOR GAS ST OVES. SELKIRK DIRECT - TEMP SYSTEM SECURIT Y CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “MET ALBESTOS MDV VENT SYSTEM” kits are available for horizontal ve[...]

  • Page 14

    V e n t R e s t r i c t o r P o s i t i o n s 5 4 3 2 1 0’ (0 m) 0’ (0 m) 5’ (1.52 m) 5’ (1.52 m) 10’ (3.05 m) 10’ (3.05 m) 15’ (4.57 m) 15’ (4.57 m) 20’ (6.10 m) 25’ (7.62 m) 30’ (9.14 m) 18’ (5.49 m) 1 2 3 4 5       [...]

  • Page 15

    15 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y P LANNING Y OUR I NSTALLATION : When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10 inches (25.4 cm), 1 inches (3.8 cm) [...]

  • Page 16

    Initial Inst alla tion QUALIFIED INST ALLERS ONL Y H ORIZONTAL I NSTALLATION : STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance. STEP 2. Direct vent pipe and ttings are d[...]

  • Page 17

    17 and attach to the exterior wall with the four screws pro vided. Before at taching the vent termination to the exterior wall, run a bead of non-hardening mastic around the edges, so as to make a seal between the termination and the wall. The arrow on the vent termination should be pointing up, insure that the proper clearances to combustible mate[...]

  • Page 18

    18 NOTES: (1) The four (4) wood screws provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or other types of siding. (2) F or buildings with vinyl siding, a vinyl siding standof f , should be installed between the vent cap and the exterior wall (see Figure 19). Attach the vinyl siding standoff to the horizontal t[...]

  • Page 19

    STEP 3. T o install the Round Support B ox/W all Thimble in a at ceiling, cut a 10” square hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 23. STEP 4 . Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up through the Round Support Box. Insure that [...]

  • Page 20

    down to the r oof level, as shown in Figur e 24. Tighten the clamp ar ound the pipe section. Use a level to make sure the pipe is truly vertical. With roong nails, secure the support straps to the roof . Seal the nails holes heads with non-hardening mastic. T rim the excess length of the support straps that extend out bey ond the edge of the [...]

  • Page 21

    21 (2) Any occupied areas above the rst oor , including closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be fr amed and sheet rocked with standard building materials. However consul t the appliance plumber ’s tape connected to wall strap W all strap 45° elbows (x2) Nails Ceiling firest[...]

  • Page 22

    Figure 28: Cathedral Ceiling Support Box Leveling. Figure 29: Cathedral Ceiling Support Box Installation. STEP 6. Complete the cathedral ceiling installation by following the same procedures outlined in Steps 4 through 9 for I NITIAL I NSTALLATION - V ERTICAL I NSTALLATION . F REESTANDING D IRECT V ENT K IT W ITH C OUPLER : KIT COMPONENTS: Quantity[...]

  • Page 23

    23 3. Set the appliance in the desired location. T emporarily place a 24” (61 cm) section with the non- crimped end on the unit 4. Install the 90° elbow onto the vertical pipe on the stove pointing in the direction that the vent will exit the structure. 5. Project a lev el line from the center point of the elbow . Using this center point, scribe[...]

  • Page 24

    Figure 32: Assembly of Venting Kit. 20. Align all str aight sections of pipe, slipping all joints together and installing with thr ee (3) sheet metal screws evenly spaced. 21. I nstall the br ass decorative rings around each joint making sure this decorativ e ring covers the sheet metal screws that secure each section of pipe together and secure to[...]

  • Page 25

    25 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y V ENTING INTO A C LASS ‘A’ C HIMNEY : This model is also certied and tested to vent into CL ASS ‘ A ’ wood stove chimneys. Place the freestanding direct vent appliance in the desired location. Use a conv ersion kit from Simpson Duravent (931, 932, or 933), or Security Chimney (SV4CCK1[...]

  • Page 26

    Firebox T op Flue Collar Adapter Undo four " screws that hold flue collar elbow to unit. Figure 34: Step 3 of Converting Top Vented into Rear Vented. Figure 35: Step 4 of Converting Top Vented into Rear Vented. I NSTALLATION OF R EAR V ENTED A PPLIANCE : Siding Exterior wall Drywall V ent pipe Inside finished collar W all thimble Minimum ve[...]

  • Page 27

    27 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y I NSTALLATION OF T OP V ENTED ; H ORIZONTAL T ERMINATION : Siding Exterior wall Drywall V ent pipe Inside finished collar W all thimble T ermination Figure 37: Installation for Top Vented; Horizontal Termination. I NSTALLATION OF T OP V ENTED ; V ERTICAL T ERMINATION : V ent cap Roof flashing Ro[...]

  • Page 28

    28 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y F REESTANDING D RAFTHOOD A DAPTOR : This Dr afthood Adaptor is a complete assembly and is ready to t onto your Westport in a vertical vent application only . With the Dr afthood Adaptor correctly installed and wired to the gas control v alve. Y our Direct V ent Fireplace can be vented like a [...]

  • Page 29

    29 Initial Inst alla tion GENERAL VENTING INFORMATION: Canadian Installations The venting system must be installed in accordance with the current CSA B149 installation code and/or local codes having jurisdiction. U.S.A. Installations The venting system must be installed in accordance with the current National Fuel Gas Code, ANSI Z223.1, and/or loca[...]

  • Page 30

    30 Initial Inst alla tion 4. After a minimum of 10 minutes operation, test the chimney draft with a smoke match at the top row of the pattern to conrm that there is adequate draft or ‘pull’ at the openings around the body of the Drafthood Adaptor , as shown in Figure 42. AUTOMATIC SAFETY SHUT DOWN: If the spill switch is activated and shuts [...]

  • Page 31

    31 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. O L I T P TP TH TP TH IN OUT H I L O N O F O F L I P T O Manifold Pressure T ap Inlet Pressure T ap Hi/Low Knob Pilot Adjustment Screw Gas Contro[...]

  • Page 32

    32 Figure 45: Gas Control Valve and Optional Thermostat Wiring. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y E LECTRICAL R EQUIREMENTS F OR G AS V ALVE AND O PTIONAL B LOWER : The ENVIRO WESTPOR T will operate without electrical power . This model has a millivolt gas control, which uses the pilot ame to generate enough electricity to oper [...]

  • Page 33

    Fan assembly V alve cover Control panel (Fan control location) Screw hole Figure 47: Optional Blower (Fan) Installation. Second ar y Inst alla tion I NSTALLATION OF O PTIONAL B LOWER : 1. Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is noticed call your dealer , distributor or courier company and have[...]

  • Page 34

    34 1. Carefully remove logs from box. Check to ensure there is no damage. It is very important to install all logs in their proper position to insure safe, optimum operating conditions. 2. Place the log set into the rebox. Locate each log by seating it down onto the burner tra y support pins. Follow Figures 48 to 54 proper log placement. 3. A ba[...]

  • Page 35

    Second ar y Inst alla tion CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. Important note: When the unit is turned on for the rst time, It should be turned onto high without the fan on for the rst four (4) hours. This will cure the paint, logs, gasket material and the other products used in the manufacturing process. It is [...]

  • Page 36

    36 Figure 57: Top brick panel in place, screws shown. Figure 58: Back brick panel in place. Figure 59: Side brick panels in place. Figure 56: Brick panel bracket, slots shown. 1. Remove the two (2) screws from the rear of the bafe, use a ” socket or a at head screwdriver . Place the provided brick brack et (Figure 56) at the rear of the [...]

  • Page 37

    T rouble Shooting Problem Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor . • Check connections to ignitor . • If ignitor connections are good but no spark, replace ignitor . Broken spark electrode. • Check f or broken cer amic insulation. • Replace electr ode if bro[...]

  • Page 38

    Reference Number Part Description Part Number 1 T op V ent Insert Piece - P ainted EGWP-503 1 T op V ent Insert Piece - Antique White EGWP-503AW 1 T op V ent Insert Piece - Diamond Black EGWP-503DB 1 T op V ent Insert Piece - Inferno R ed EGWP-503IR 1 T op V ent Insert Piece - P earl Grey EGWP-503PG 1 T op V ent Insert Piece - W edgewood B lue EGWP[...]

  • Page 39

    39 Reference Number Part Description Part Number 6 Cast Leg (Each) - Painted EGWP-508 6 Cast Leg (Each) - Antique White 50-375 6 Cast Leg (Each) - Diamond Black 50-376 6 Cast Leg (Each) - Inferno R ed 50-377 6 Cast Leg (Each) - Pearl Gr ey 50-378 6 Cast Leg (Each) - W edgewood Blue 50-379 6 Cast Leg (Each) - W estport Green 50-380 6 Cast Leg (Each)[...]

  • Page 40

    P ar ts Diagr am - Cast         WESTPORT - Castings January 2005 40[...]

  • Page 41

    41 P ar ts List - Components Reference Number Part Description Part Number 9 120° Ceramic F an T emperature Sensor EC-001 10 S.I.T . Nova V alve NG (50% T urn Down) EC-006 10 S.I.T . Nova V alve LP (50% T urn Down) EC-007 11 Thermocouple EC-009 11 Spark Electrode with Ignitor Cable EC-011 11 Thermopile EC-012 11 Pilot Orice NG Threaded EC-019 1[...]

  • Page 42

    P ar ts List - Components Reference Number Part Description Part Number 17 Rating Plate (Label) 30-049 18 Gas V alve Cov er 30-050 Flue Connection 30-051 19 Inner Door Handles (2 per set) 30-052 20 V enturi Adjustment Rod 30-053 21 Firebox 30-054 22 Burner 30-055 23 45° Elbow & Gasket 50-040 24 F an Kit 180 C.F .M. 50-173 Door Knob - Brushed N[...]

  • Page 43

    43 P ar ts Diagr am - Components                      WESTPORT - Components January 2005[...]

  • Page 44

    W arr anty Sherwood Industries Ltd. offers a Limited Lifetime Warr anty on this gas product. This limited lifetime warr anty covers the appliance for a period of seven years from the date of installation. This warr anty applies only to the original owner in the original location Covered under the lifetime warr anty are, Surround Panels and Chassis [...]

  • Page 45

    45 Inst alla tion Da t a Sheet The following information must be recorded by the installer f or warr anty purposes and f uture refer ence. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:_____________[...]