Go to page of
Similar user manuals
-
Stove
Enviro Cara DR
35 pages 3.23 mb -
Stove
Enviro 50-1021
14 pages 0.98 mb -
Stove
Enviro Mini Freestanding Pellet Stove
2 pages 0.78 mb -
Stove
Enviro C-10804
13 pages 1.16 mb -
Stove
Enviro 50-1675
16 pages 0.89 mb -
Stove
Enviro 1700 Fireplace Insert
45 pages 2.94 mb -
Stove
Enviro EG40 DV
33 pages 2.09 mb -
Stove
Enviro Evolution
36 pages 2.32 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Enviro C-11148, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enviro C-11148 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Enviro C-11148. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Enviro C-11148 should contain:
- informations concerning technical data of Enviro C-11148
- name of the manufacturer and a year of construction of the Enviro C-11148 item
- rules of operation, control and maintenance of the Enviro C-11148 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enviro C-11148 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enviro C-11148, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enviro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enviro C-11148.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Enviro C-11148 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PELLET ST OVE Ber n PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area. SHERWOOD INDUSTRIES IS [...]
-
Page 2
2 Introduction...................................................................................................................................3 Rating Label Location................................................................................................................3 Important Safety Data...............................................[...]
-
Page 3
3 Introduction * This manual is designed for the technician in conjunction with the owner’s manual. * R ATING L ABEL L OCATION : The rating label is located on the back of the unit. I MPORTANT S AFETY D ATA : Please read this entire Owner’s Manual before installing or operating this ENVIRO Pellet Stove. Failure to follow these instructions may [...]
-
Page 4
4 Introduction ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 220-240 volts,, nominal aver age 0.8 Amps (1.4 Amps peak), 50 hertz electrical outlet and also must be accessible. If this power cord should become damaged, a replacement power c[...]
-
Page 5
5 Inst alla tion D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage or any unv entilated space. Combustion air may be obtained from a ventilated cr awlspace. 3. Do not install the stove in a bedroom. 4. Y ou can vent the stove through an exterior wall behi[...]
-
Page 6
6 Inst alla tion A PPLIANCE D IMENSIONS AND S PECIFICATIONS : Figure 2: Dimensions of Bern. 15 1 / 2 " (393 mm) 18 7 / 8 " (481 mm) 17 1 / 2 " (444 mm) 19 5 / 8 " (497 mm) 17 7 / 8 " (455 mm) 34 3 / 4 " (883 mm) W eight (with full hopper): 238 lb (108 Kg) Hopper Capacity: up to 52 lb (23.6 Kg) V oltage: 220 - 240 V Max[...]
-
Page 7
7 Inst alla tion C LEARANCES TO C OMBUSTIBLES : Use a hearth pad that extends 6 inches (15 cm) in front of the unit when instal ling on a combustible floor . A LCOVE C LEARANCES : This unit may be instal led in an alcove. Maintain these clearances to combustibles. Minimum Alcove width 48 inches (122 cm) Minimum Alcove height 48 inches (122 cm) Maxi[...]
-
Page 8
fumes such as stairwells, cover ed breezeway , etc. 2. V ent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be requir ed. 3. T ermination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be installed outside when the appliance is vented [...]
-
Page 9
9 Inst alla tion E XHAUST L OCATION : 8 3 / 4 " (222mm) 10 3 / 4 " (273mm) Figure 6: Bern Inlet and Outlet Location. Base of unit to center of flue 10” (273 mm) Side of unit to center of flue 8” (222 mm) [at center of unit] Figure 7: Corner Installation. C ORNER T HROUGH W ALL I NSTALLATION : 4" (8 cm) 4" (8 cm) W all [...]
-
Page 10
10 Inst alla tion H ORIZONTAL E XHAUST T HROUGH W ALL I NSTALLATION : Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor , or ceiling. Where passage through a wall or partition of combustible construction [...]
-
Page 11
11 Inst alla tion 10. Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless steel cap termination manufactured by the vent manufacturer is recommended. However , when the vent terminates several feet above ground level and there are no trees, plants, etc. within sever al feet, a 45° elb[...]
-
Page 12
?[...]
-
Page 13
13 H EARTH M OUNT I NSTALLATION : Inst alla tion Rain cap Flashing 24" (61 cm) 4" (10 cm) T ee with cleanout 3" (7.5 cm) Clearance Support bracket T ype "L" vent Figure 13: Outside V ertical Installation. Ref er to Figures 14 and 15. 1. Install the hearth pad. 2. Lock fireplace damper in the open position. 3. Install a posi[...]
-
Page 14
14 Inst alla tion Rain cap Storm collar Seal plate (cover plate) Existing masonry flue V ent pipe (single wall stainless flex pipe or solid PL vent) Fireplace damper location Clean out tee Existing fireplace Flexible vent connector (use this 5 foot [152cm] section of pipe to vent past fireplace damper or small shelf) Figure 15: Freestanding hearth [...]
-
Page 15
Inst alla tion E XTERIOR M OUNTED E XHAUST B LOWER : The Bern can be equipped with an externally mounted exhaust blower . This optional kit includes all components necessary to install the exhaust blower on any vertical w all surface. 1. Remove the left hand cabinet side by removing the two (2) screws down the front. Loosen the three screws on the [...]
-
Page 16
Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - H ORIZONTAL T ERMINATION : Electrical Cable Bern 90° Elbow 45°Elbow with Rodent screen or stainless steel termination hood 2ft (610mm) Riser Pipe Adaptor Exterior Blower and Housing W all Strap T o supply power to the exhaust blower Install an amour coated electri[...]
-
Page 17
17 Bern Roof Sheathing Rain Cap Roof Flashing Roof Rafters Ceiling Joists V ent Pipe Exterior W all Sheathing Outside V ent T ermination Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - V ERTICAL T ERMINATION : F ollow the previous pages for through wall installations. Ensure that vent pipe is properly secured to [...]
-
Page 18
Inst alla tion T HERMOSTAT I NSTALLATION : If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is displayed on the control board Heat Indicator . If the heating load is not great enough [...]
-
Page 19
19 If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly , decreasing the air in the firebox. If , after long periods of burning, the fire builds up and overflows the burn pot or there is a build up of clinkers, this would be a sign that the pellet qualit[...]
-
Page 20
20 Inst alla tion O PTIONAL P ANEL K IT : This kit must be installed before the unit is started. Figure 29: Screws at back of the cab side. Figure 27: Screws above door top corner . Figure 28: Screw behind ash box. Tools Required: ●T -20 screwdriver Kit Components: Quantity Description 1 Left Cab P anel 1 Right Cab P anel 1 Hopper Lid 20 #8 T -20[...]
-
Page 21
21 Inst alla tion 1 2 3 Figure 30: Installing Hopper Lid. Installing Hopper Lid: 1. Attach the hopper br ackets to the back of the unit with a screw in each top holes of the brackets (#1 in Figure 30). Do not tighten these screws until all six (6) screws are in place. 2. Lay the hopper lid in place, slide the bushing into the br acket, and attach t[...]
-
Page 22
T roubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly . Only qualified technicians should deal with possible internal electrical failures. ● Do not remove f rom the firebox any screws without penetr ating oil lubrication. WHAT TO DO IF: 1. The stove[...]
-
Page 23
23 T roubleshooting ü P oor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational. ü Exhaust T emper ature Sensor f ailure. – Bypass sensor located on Exhaust Blower if stove now operates properly , the unit may require cleaning or a new sensor . Contact your local dealer for service. ?[...]
-
Page 24
T roubleshooting 7. The convection blower will not function normally. ü Clean all grill openings at the back and below unit . ü Press the fan button; does the f an come on? Press again to verify that the blower turns on; if , not contact your local dealer for service. 8. Ignitor- the pellets will not light. ü Everything else in the stov e operat[...]
-
Page 25
25 W iring Diagr am Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White White 115V White 220V Blue White White Orange Orange Orange Orange Yellow Yellow Grey Grey Grey Grey Purple Purple Blue 115V Black 220V Brown Black Black Black Blue Black Black Armor Cable Supplied Vacuum Switch Combustion Blower Optional Ext[...]
-
Page 26
P ar ts List Reference Number Description Part Number 1 120°F (49°C) Ceramic F an T emperatur e Sensor EC -001 2 Auger Motor - 220V EF-001-220V 3 High Limit T emp Sensor 200°F (93°C) Manual Reset EF-016 4 V acuum Switch - 220V EF-017-220V Silicone Hose EF-018 Aluminum Hose Barb EF-019 Shoulder Bolt, Hardened Bush & Nut (Set of 2) EF-124 Aug[...]
-
Page 27
27 P ar ts List Reference Number Description Part Number 17 Circuit Board, 2 second on time - 230V 50-1160 18 Auger with P addles 50-1161 19 Brick Panel Set with Insulation 50-1162 20 Side Louver - Right 50-1163 21 Side Louver - Left 50-1164 22 Burn Pot 50-1166 23 Burn Pot Liner 50-1167 24 Burn Pot Bottom 50-1168 25 Front Louvers 50-1169 26 Lid Set[...]
-
Page 28
P ar ts Diagr am - Components Bern - Components February 2005 28[...]
-
Page 29
29 P ar ts Diagr am - Steel Bern - Steel Components February 2005 [...]
-
Page 30
W arr anty Sherwood Industries Ltd. gives a five year limited warrant y on all steel manufactured parts. A one-y ear warr anty is provided on all electrical components. The abo ve limited warranties are extended only to the original purchaser . There is no warr anty on the following parts: ● Glass window ● Fiberglass rope gaskets ● refr actor[...]
-
Page 31
31 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ NAME OF DEALER: _________________________________________ ADDRESS: _________________________________________ ____[...]