Go to page of
Similar user manuals
-
Indoor Fireplace
Enviro C-10794
45 pages 3.33 mb -
Indoor Fireplace
Enviro DV50DX
36 pages 2.46 mb -
Indoor Fireplace
Enviro ASCOT VENTED GAS FIREPLACE HEATER
42 pages 4.12 mb -
Indoor Fireplace
Enviro C-11275
42 pages 3.22 mb -
Indoor Fireplace
Enviro C-10791
35 pages 2.44 mb -
Indoor Fireplace
Enviro Sienna Indoor Gas Fireplace
32 pages 2.21 mb -
Indoor Fireplace
Enviro Vented EG 28 B
20 pages 0.84 mb -
Indoor Fireplace
Enviro C-11290
48 pages 3.05 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Enviro C-11253, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enviro C-11253 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Enviro C-11253. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Enviro C-11253 should contain:
- informations concerning technical data of Enviro C-11253
- name of the manufacturer and a year of construction of the Enviro C-11253 item
- rules of operation, control and maintenance of the Enviro C-11253 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enviro C-11253 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enviro C-11253, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enviro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enviro C-11253.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Enviro C-11253 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE 50-1472 S o n n e t This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible f [...]
-
Page 2
FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst. Consult the building authority having jurisdiction to determine the need [...]
-
Page 3
T able of Contents 3 Safety Precautions...........................................................................................................2 T able of Contents.............................................................................................................3 Codes And Approv als.....................................................[...]
-
Page 4
DIRECT VENT: This type is identied by the sufx DV . This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. BV: This V ented appliance dra ws all of its combustio[...]
-
Page 5
Specific a tions R ATING L ABEL L OCATION : The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the replace. D IMENSIONS : 5 1 1 1 / 16 " (44mm) 8 1 / 2 " (216mm) 13 7 / 8 " (362mm) 7 7 / 16 " (188mm) 5 7 / 16 " (138mm) 12 3 / 16 " (309mm) 4 5 / 8 "[...]
-
Page 6
6 Specific a tions Figure 2: Sonnet Adjustable Surround, Classic, and Base Shelf with Riser. 20 13 / 16 ” (528mm) 31” (794mm) 21 13 / 16 ” (555mm) to 26 5 / 16 ” (669mm) 31 7 / 8 ” (809mm) to 40” (1035mm) 22 7 / 16 ” (569mm) 23” (583mm) Table 1: Sonnet Options Dimensions. Colonial - 3 Sided Colonial - 4 Sided Classic - 3 Sided[...]
-
Page 7
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. L IGHTING AND T URNING O FF I NSTRUCTIONS : Figure 3: Lighting instruction label. 1. ARRÊTEZ! Lire les instructions de sécurité mentionnées plus haut. 2. Ajustez le thermostat à son plus bas niveau.[...]
-
Page 8
Oper a ting Instructions The Sonnet is designed to gr adually lower or r aise the ame as is needed in application. It normally does not just turn on and off . This is v ery dependant on the size of the r oom the unit is located in. During the rst sever al operational cycles the electronics go through a learning process that establishes how th[...]
-
Page 9
TIMER MODE – (appliance must be in standby mode; pilot ignited): The Timer mode is normally programmed to hav e two (2) Periods: P1 and P2. Between these two (2) periods, a lower operating temper ature (or pilot only) can be set. Note: that between those periods, if the thermostat is set to a certain minimum temp (example 58°F (14.5°C)), then t[...]
-
Page 10
10 Oper a ting Instructions There is one venturi adjustment. Use this venturi adjustment lever , shown in Figure 8, to achieve a proper and efcient ame. Pull the rod forward for more air or push it in for less air . Adjust lever until the ame pattern is similar to Figure 79. Figure 8: Adjusting the venturi air setting. C ONTROL P ANEL : Pr[...]
-
Page 11
Maintenance And Ser vice Warning: F ailure to position the parts in accordance with this manual, or failure to use only parts specically approved with this appliance, ma y result in property damage or personal injury . At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the burne[...]
-
Page 12
Maintenance And Ser vice G LASS D OOR R EMOVAL : C LEANING T HE P AINTED S URFACES : P ainted faces should be wiped with a damp cloth periodically . R EPLACING T HE B ATTERIES : It is recommended that the batteries are replaced at the beginning of each heating season. Batteries must be changed when an acoustic error message is heard. Do not use met[...]
-
Page 13
13 Sonnets are to be installed, conrm that the remote control signal codes are different f or each unit.T o change the code, complete the following: 1. Change DIP switch position (shown at the top of Figure 13). 2. Press and hold the receiver’ s reset button (see Figure 14) until you hear two (2) acoustic signals. After the second longer acous[...]
-
Page 14
Warning: This conversion kit shall be installed by a qualied service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a re, explosion or production of carbon monoxide may result causing p[...]
-
Page 15
Figure 22: Burner Removal. Figure 21: Unfastening Burner. Maintenance And Ser vice Kit Parts List: 1 - Orice (Natural Gas #42 DMS or Pr opane #54 DMS) 1 - Conversion label 1 - Installation instruction sheet Carefully inspect the orice supplied with this conversion kit. If it has been damaged or is missing, contact your dealer , distributor or[...]
-
Page 16
c) Set the black spring depressor according to the gas used. The black spring depressor has two (2) teeth at each end that t in to the brass nut but only one end has a larger disc. If the disc si ts inside the cap then the v alve is set for natural gas and if the disc is pointing out then the valve is set for propane (see Figure 28). d) R einsta[...]
-
Page 17
17 Initial Inst alla tion WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. C LEARANCES TO C OMBUSTIBLES : Maintain sufcient clearances f or operation, service and maintenance. • A clearance of 7” (191 mm) minimum is r[...]
-
Page 18
Door removed f or clarity ” T ube Initial Inst alla tion QUALIFIED INST ALLERS ONL Y B-V ENT M ODEL : WARNING: This appliance has been designed to operate by drawing combustion air and dilution air from the room. It is also designed to draw room air for proper heat circulation from the sides of the uni t. Blocking or modifying these openings i[...]
-
Page 19
19 7 . As you push the unit into its nal position in the replace, if the vent collar plate was removed, reinstall it to the stove by sliding it along the draft hood and secure with the screws previously removed. 8. Using a ” hex driver , adjust the levelling legs to ensure the unit is level and high enough if a base shelf and/or riser is[...]
-
Page 20
Figure 33: Spill Switch Wires Fed Through Back Panel. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Figure 34: Remove Jumper From Thermocouple. Figure 35: Spill Switch Wires Connect to Thermocouple. Figure 36: Remove Flue Slider Plate & Gasket. Figure 37: Install Spill Switch on Bracket. f ) Re-attach the back panel. g) Using a T -20 screw[...]
-
Page 21
21 Note: T o convert a B-V ent to a Direct V ent, remove the air intake plug, remove the spill switch assembly and re-install the ue slider bottom plate, re-install the jumper onto the thermocouple wire, re-install the air intake cover plates, install the proper venting, re-install the screw into the draft tube at the front top of the unit. Figu[...]
-
Page 22
Install sealed throat connector or flashing to prevent leakage of room air up through chimney . DV Only: Before installing vent liners, mark each liner on both ends to designate which is the intake and the exhaust. Measure the height of the chimney beforehand and purchase the appropriate kit. Never atte[...]
-
Page 23
23 18" (457mm) 18" (457mm) T rim flashing as required. Figure 41: Vertical Vent Cap Dimensions. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y D IRECT V ENT V ERTICAL V ENT T ERMINATION : For use with Sonnet Direct Vent Fireplace Insert. The V ertical V ent Cap is termination, rain cap, and a throat connector , it will ensure a tight [...]
-
Page 24
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y The height for the vent must be between 10ft (3.05m) and 35ft (10.67m). Install sealed V ertical V ent Cap to prevent leakage of room air up through chimney . The intake is 2" (51mm) and the exhaust is 3" (76mm). Measure the height of the chimney beforehand and purchase the appropriate ki[...]
-
Page 25
25 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y E LECTRICAL R EQUIREMENTS : The f an will not operate if the appliance is cold. A few minutes after the appliance is lit and the fan is set to low or high, the fan will automatically turn on. The fan wil l automatically turn off after the appliance has cooled down. F an Control Black White Grey [...]
-
Page 26
Figure 47: Installing Fan onto Back Panel. Figure 46: Removing/Installing Back Panel From Sonnet. O PTIONAL F AN K IT : Tools Required: ● ” Socket or Driver or Flat Head Screwdriv er ● Utili t y Knife Kit Contents: Quantity Description 1 F an Kit Assembly (includes Back Cabinet P anel, F an, Mounting Bracket, P ower Cord, 1 Wiring Harness [...]
-
Page 27
27 Fan Only Replacement: 1. Unplug the power or turn off the electrical breaker for the unit. 2. Follow steps 1-4 in R EMO VING V ALVE C OVER - M AINTENANCE A ND S ERVICE . 3. The fan hangs on a grommet at either end of the mounting bracket (see Figure 47), lift the fan assembly up and off the grommets. 4. Slide the fan forward, mark the three (3) [...]
-
Page 28
28 Pilot Line Thermocouple Line Gas Line In Gas Line Out Pressure T ap Out Pressure T ap In Main V alve Knob • A shut-of f valv e is not supplied with this unit but one should be installed. • The appliance and its shut-of f v alves must be disconnected from the gas supply piping system during any pressure testing wher e the pressure exceeds [...]
-
Page 29
R EMOTE H ANDSET W ALL B RACKET I NSTALLATION : Kit Contents: Quantity Description 1 W all Bracket (T op & B ottom) 1 Spacer 1 Countersink Head Screw 2 P an Head Screw 2 Spacer 55: Wall Bracket Installation Option 1. Figure 56: Wall Bracket Installation Option 2. Figure 57: Wall Bracket Installation Option 3. Note: The spacer maybe found betwee[...]
-
Page 30
30 Second ar y Inst alla tion O PTIONAL B ASE S HELF & R ISER : The Sonnet Base Shelf (1” (41 mm) high) and Base Shelf Riser (2” (54 mm) high) are black powder coated components that can be combined to create a riser wi th an ov erall height of 2 3 / 16 ” (55 mm). This shelf can be installed with or without the riser and can be used[...]
-
Page 31
31 Second ar y Inst alla tion Note: The Adjustable Surround can only be instal led onto the Colonial or Classic Surrounds, it is not intended to be installed on its own with the Sonnet unit. ASSEMBLY: 1. Line up the two (2) scr ew holes in the left hook br acket with the second slot in on the back of the left trim side (refer to Figure 60). Center [...]
-
Page 32
32 Figure 64: Installing Mounting Bracket. 39” (997mm); this falls into the large adjustable surr ound range. Note: The bottom of the keystone and surround corners can be trimmed to make the surround smaller . b) Subtract the minimum size of the surround (21” (552mm) x 31” (809mm) for the small and 24” (609mm) x 36” (921mm) fo[...]
-
Page 33
Figure 66: Bushing Locations. Surround is removed for clarity . Figure 67: Bushing and Hook Close-Up. INSTALLATION: Lift the trim upright in front of the replace with the four (4) hooks pointing towards the replace. Slide the hooks over their corresponding bushings (see Figures 66 & 67). Ensure the hooks are secure befor e releasing the t[...]
-
Page 34
B RICK P ANEL I NSTALLATION : NOTE: The brick liner is fragile and should be handled gently. 1. Ensure the Sonnet is turned off and allow the unit to cool. 2. Remo ve the glass door as shown in the M AINTENANCE AND S ERVICE - G LASS D OOR R EMOV AL . Warning: Do not touch or attempt to remove the glass if the replace is not completely cold. Neve[...]
-
Page 35
35 Second ar y Inst alla tion L OG S ET AND E MBER I NSTALLATION : NOTE: The logs are fragile and should be handled gently. Figure 72. Empty rebox. Ledges Figure 73. First Stage Log Set Installation. Figure 74. Second Stage Log Set Installation. Pin Figure 73: The back left log rests behind the left ledge pointed out in Figure 72. The front of t[...]
-
Page 36
Second ar y Inst alla tion Pins Figure 75. Third Stage Log Set Installation. Figure 77. Fifth Stage Log Set Installation. Figure 76. Fourth Stage Log Set Installation. Figure 75: The center of the right log ts onto the locator pin on the back right log (see Figure 74). The front of the log is to rest on the burner and the back end of the log res[...]
-
Page 37
37 Second ar y Inst alla tion Figure 79. Sonnet complete log set-up with embers burning. NOTE: While the glass is still removed, it is recommended that the gas line be purged by lighting the pilot. When lighting the replace for the rst time since the log set and embers have been installed/replaced, watch for ignition at ALL the burner ports. [...]
-
Page 38
T rouble Shooting Problem Possible Cause Solution No transmissions; remote control doesn’t work. Receiv er must learn new code. • Reset the r eceiver’s code, r efer to M AINTENANCE A ND S ERVICE - C HANGING R EMOTE H ANDSET C ODE . One or more of the batteries are dead. • Replace the bat teries, refer to M AINTENANCE A ND S ERVICE - R EPLAC[...]
-
Page 39
39 Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor . Air in the pilot supply line. • Purge the line or start ignition sever al times. No spark at pilot burner • Check spark gap . • Check wiring connections to ignitor . • Check for spark in location along cable. V alve. • Replace the v alv[...]
-
Page 40
T rouble Shooting Problem Possible Cause Solution 3 short beeps while motor turns. One or more of the batteries are low . • Replace the bat teries, refer to M AINTENANCE A ND S ERVICE - R EPLACING T HE B AT TERIES . W ARNING : Creating an electrical short between the batteries/battery box and metal parts of the appliance may render the receiver i[...]
-
Page 41
P ar ts List 41 Reference Number Part Description Part Number 1 120°F (49°C) Cer amic F an T emperature Sensor EC-001 2 FPI Burner Switch EC-026 3 Domestic P ower Cord (115V) EC-042 4 Heyco Str ain R elief EC-044 5 Embers (Coal & W ool) EC-046 6 Conv ection Blower 115V 50-1549 12 oz. Can of Flat Black T ouch Up Paint P AINT -12-FB 7 Blank Ori[...]
-
Page 42
Reference Number Part Description Part Number 28 PSE Thermocouple 50-1502 29 Sonnet 300°F (149°C) Spill Switch with Wires & Bracket 50-1503 30 GV60 Gas V alve 50-1504 31 GV60 Control Box 50-1505 32 GV60 Control Box V alve Cable 50-1506 33 GV60 3 Button Switch with Cable 50-1507 34 GV60 Battery Clip 50-1509 35 GV60 Battery Cable 50-1510 36 Son[...]
-
Page 43
P ar ts Diagr am - Components SONNET - Components February 2007 43[...]
-
Page 44
P ar ts Diagr am - Options SONNET - Options November 2006 44[...]
-
Page 45
45 W arr anty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. A t Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the nest materials and is backed by our Exclusive Lifetime Limit[...]
-
Page 46
W arr anty 4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this W arranty policy . P erformance problems due to operator error will not be covered by the Limited W arr anty policy . 5. As this is [...]
-
Page 47
47 20. Sherwood Industries Ltd. is free of liability for any damages caused by the replace or stove, as well as inconvenience expenses and materials. The Limited W arrant y does not cover incidental or consequential damages. 21. The Limited W arrant y does not cover any loss or damage incurred by the use or remov al of any component or apparatus[...]
-
Page 48
48 Inst alla tion Da t a Sheet The following information must be recorded by the installer for w arrant y purposes and future r eference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:______________[...]