Go to page of
Similar user manuals
-
Indoor Fireplace
Enviro ASCOT VENTED GAS FIREPLACE HEATER
42 pages 4.12 mb -
Indoor Fireplace
Enviro VENTED GAS FIREPLACE HEATER
42 pages 3.93 mb -
Indoor Fireplace
Enviro Haven Haven Direct Vent Fireplace
41 pages 2.72 mb -
Indoor Fireplace
Enviro Omega
16 pages 0.89 mb -
Indoor Fireplace
Enviro C-10381
48 pages 3.05 mb -
Indoor Fireplace
Enviro C-10791
35 pages 2.44 mb -
Indoor Fireplace
Enviro 50-1033
48 pages 4.66 mb -
Indoor Fireplace
Enviro C-11290
48 pages 3.05 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Enviro C-11290, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enviro C-11290 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Enviro C-11290. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Enviro C-11290 should contain:
- informations concerning technical data of Enviro C-11290
- name of the manufacturer and a year of construction of the Enviro C-11290 item
- rules of operation, control and maintenance of the Enviro C-11290 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enviro C-11290 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enviro C-11290, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enviro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enviro C-11290.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Enviro C-11290 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD OWNER’S MANUAL PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE 50-1033 W e s t p o r t This appliance may be installed in an after-market permanently located, manufactured (mobile) home, where not prohibit[...]
-
Page 2
2 FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIRO” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Car efully r ead all the instructions in this manual rst. Consult the building authority having jurisdiction to determine the ne[...]
-
Page 3
T able of Contents 3 Safety Precautions..................................................................................................................2 T able of Contents...................................................................................................................3 Codes And Approv als........................................[...]
-
Page 4
4 DIRECT VENT ONLY: This type is identied by the sux DV . This appliance dra ws all of its air for combustion from outside the dwelling, through a specially designed v ent pipe system. TOP VENT DV Certied for installation from 0-4500 ft (0-1372 m) REAR VENT DV Certied for installation from 0-4500 ft (0-1372 m) with 36” (915 mm) snorke[...]
-
Page 5
5 Specific a tions WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. D imensions : 16 5 / 8 " (42.2cm) 25 ¾" (65.3cm) 25 ¾" (65.4cm) 27" (68.6cm) 25 ¾" (65.3cm) 17 1 / 8 " (43.5cm) 15 ¾" (4[...]
-
Page 6
6 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P iLot L ighting i nstRuctions : Figure 2. Lighting Instruction Label 1. Flip burner switch [...]
-
Page 7
7 2. Start the pilot by pressing the gas control knob and turning it to PILO T . While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see Figure 3). 3. Start the main burner by turning[...]
-
Page 8
8 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating R emote contRoLs (o PtionaL ): This replace can use an optional remote control or an optional cordless wall thermostat. If either of these are to be used to control the replace for the majority of the time, leave the ON/OFF switch (o[...]
-
Page 9
Electronic ignition module Maintenance And Ser vice R outine m aintenance : At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pi lot ame should be blue with l[...]
-
Page 10
Figure 6: Handles for Removing Door. Figure 7: Removing of Door. Maintenance And Ser vice R ePLacing the g Lass : The glass in the replace is a high temperature ceramic. If the glass is damaged in any wa y , a factory replacement is required (see P artS l iSt - c oMPonentS ). Wear gloves when handling damaged glass door assembly to prevent perso[...]
-
Page 11
11 Using a ½" deep socket remove/reinstall the main burner orifice. Undo the two (2) screws that hold burner in the firebox. Rotate handles and remove the door and glass. Lift off the pilot head and replace with proper pilot orifice for fuel type to be used. V enturi adjustment bracket. Pilot assembly moved from firebox for clarity . Figure 8[...]
-
Page 12
12 Figure 9: Removing valve cap. Maintenance And Ser vice the HI/LO knob by hand shown in Figur e 9. Figure 11: Flip valve screw. Red o-ring is not visible Red o-ring is visible LPG Configuration b) Insert a 5 / 32 ” or 4 mm Allen wrench into the hexagonal key -wa y of the screw (see Figure 10), rotate it counter-clockwise until it is free and ex[...]
-
Page 13
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. P RePaRation F oR i nstaLLation : • Remov e the packaging f rom the appliance, and check to make sure there is no damage. If [...]
-
Page 14
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Vertical Termination Storm Collar Flashing Round Support Box/Wall Thimble Ceiling Firestop Pipelength Pipelength Cathedral Ceiling Support Box Pipelength Round Support Box/Wall Thimble Pipelength Horizontal Termination 90° Elbow Y our total vent pipe length must be within the shaded area of Figure[...]
-
Page 15
15 1 In accordance with the current CSA B149, Natur al Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFP A 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the r equirements of the gas supplier . t A vent shall not terminate directly above a side w [...]
-
Page 16
16 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Wire spacers Figure 19: Wire Spacers. it to the inner wall fr ame using four (4) 1½” wood screws. If a wall is greater than 8” (203mm) in depth, the clearance above the ex must be 4⅜” (111mm) 6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5 cm) provid[...]
-
Page 17
Flue Pipe Adaptor W all Framing W all Thimble Fire Stop Exhaust 4" Flex Pipe Combusion Air 6 5 / 8 " Flex Pipe Wire Spacers Horizontal V ent T ermination Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Figure 21: Installation of Fireplace Horizontal Vent Kit. 10. Apply a bead of Mil l-P ac Black sealant to the top section of the Ø4”[...]
-
Page 18
18 EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct V ent GS starting collar in conjunction with Secure V ent, Direct- T emp, and Ameri V ent Direct venting systems. Use of these systems with the Direct V ent GS starting col lar is deemed acceptable and does not affect the Intertek WH listing of the appliance. Ta[...]
-
Page 19
1 2 3 4 5 View showing fully open restrictor plate View showing fully closed restrictor plate 1 2 3 4 5 Figure 22: Restrictor plate settings. The ENVIRO WESTPOR T has been designed wi th a built in restrictor plate. The restrictor is designed to enhance ame appear ance when installing this unit with vertical chimneys as well as installations wit[...]
-
Page 20
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y h oRizontaL i nstaLLation : 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of Sealant Female Locking Lugs Male Locking Lugs Figure 25: Twist-L[...]
-
Page 21
21 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Wood screws (x4) Cut vinyl siding away to fit standoff Bolt (x4) required Nut (x4) required Wood screw (x4) Figure 28: Installing Vent Cap with Vinyl Siding Stand-Off. Figure 29: Installing Horizontal Vent Termination. wall, run a bead of non-hardening mastic around the edges, so as to make a se[...]
-
Page 22
3. T o install the R ound Support Box/W al l Thimble in a at ceiling, cut a 10” square hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 30. 4 . Assemble the desired lengths of black pipe and elbows neces sary to reach from the appliance adapter up through the Round Support B o x. Insure that all pi[...]
-
Page 23
23 the support straps that extend out bey ond the edge of the ashing. 7. Slip the ashing over the pipe section protruding thr ough the roof . Secure the base of the ashing to the roof with roong nails. Use a non-hardening sealant between the uphill edge of the ashing and the roof . Insure the roong material ov erlaps the top edge [...]
-
Page 24
plumber ’s tape connected to wall strap W all strap 45° elbows (x2) Nails Ceiling firestop Ceiling Second floor Use clearances to as defined by appliance and vent pipe manufacturers. c atheDRaL c eiLing i nstaLLation : Figure 33: Use of Wall Straps. Figure 34: Multi-Story Vent Pipe Installation. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y[...]
-
Page 25
25 Figure 36: Cathedral Ceiling Support Box Installation. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y 2 1 /2” (67 mm) Inside Wall Outside Wall 36” (915 mm) Snorkel Outside Wall Outside Wall 2 1 /2” (67 mm) Figure 37: Corner installation rear vented with snorkel. Figure 38: Corner installation top vented. c oRneR i nstaLLations : Do not[...]
-
Page 26
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y v enting into a c Lass ‘a’ c himney : This model is also certied and tested to vent into CL ASS ‘ A ’ wood stove chimneys. Place the freestanding direct v ent appliance in the desired location. Use a conv ersion kit from Simpson Durav ent (931, 932, or 933), or Security Chimney (SV4CCK1,[...]
-
Page 27
27 Firebox T op Flue Collar Adapter Undo four ¼" screws that hold flue collar elbow to unit. Figure 40: Step 3 of Converting Top Vented into Rear Vented. Figure 41: Step 4 of Converting Top Vented into Rear Vented. i nstaLLation oF R eaR v enteD a PPLiance : Siding Exterior wall Drywall V ent pipe Inside finished collar W all thimble Minimum [...]
-
Page 28
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y i nstaLLation oF t oP v enteD ; h oRizontaL t eRmination : Siding Exterior wall Drywall V ent pipe Inside finished collar W all thimble T ermination Figure 43: Installation for Top Vented; Horizontal Termination. i nstaLLation oF t oP v enteD ; v eRticaL t eRmination : V ent cap Roof flashing Roof [...]
-
Page 29
29 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y F ReestanDing D RaFthooD a DaPtoR - 50-841: This Dr afthood Adaptor is a complete assembly and is ready to t onto your W estport in a vertical vent application only . With the Drafthood Adaptor correctly installed and wired to the gas control valv e. Y our Direct V ent Fireplace can be vented[...]
-
Page 30
The minimum clear ance to combustibles is 6” (150 mm) when using single w all venting and 1” (25 mm) when using “B-v ent” venting. W e strongly recommend installing an approved chimney liner in an existing brick chimney . This will maximize the potential dr aft of the chimney and lessen the effects of slow chimney start -up. VENTING OF A FI[...]
-
Page 31
31 Initial Inst alla tion AUTOMATIC SAFETY SHUT DOWN: If the spill switch is activ ated and shuts off the main burner the following procedure should be followed. • I s the pilot ame still on? If not, the reason for the replace shut down is not the spill switch. • T urn off the pilot ame and turn off all controls. Let replace to cool[...]
-
Page 32
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y g as L ine c onnection anD t esting : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. O L I T P TP TH TP TH IN OUT H I L O N O F O F L I P T O Manifold Pressure T ap Inlet Pressure T ap Hi/Low Knob Pilot Adjustment Screw Gas Control K[...]
-
Page 33
33 Figure 51: Gas Control Valve and Optional Thermostat Wiring. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y e LectRicaL R equiRements F oR g as v aLve anD o PtionaL b LoweR : The ENVIRO WESTPOR T will operate without electrical power . This model has a millivolt gas control, which uses the pilot ame to generate enough electricity to opera[...]
-
Page 34
Fan assembly V alve cover Control panel (Fan control location) Screw hole Figure 53: Optional Blower (Fan) Installation. Second ar y Inst alla tion i nstaLLation oF o PtionaL b LoweR : 1. Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is noticed call your dealer , distributor or courier company and hav [...]
-
Page 35
35 1. Carefully remov e logs from box. Check to ensure there is no damage. It is very important to install all logs in their proper position to insure safe, optimum operating conditions. 2. Place the log set into the rebox. Locate each log by seating it down onto the burner tra y support pins. Follow Figures 48 to 54 proper log placement. 3. A b[...]
-
Page 36
Second ar y Inst alla tion CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. Important note: When the unit is turned on for the rst time, It should be turned onto high without the fan on for the rst four (4) hours. This will cure the paint, logs, gasket material and the other products used in the manufacturing process. It is [...]
-
Page 37
37 Figure 63: Top brick panel in place, screws shown. Figure 64: Back brick panel in place. Figure 65: Side brick panels in place. Figure 62: Brick panel bracket, slots shown. 1. Remove the two (2) screws from the rear of the bafe, use a ¼” socket or a at head screwdriver . Place the provided brick bracket (Figure 62) at the rear of the ba[...]
-
Page 38
38 T rouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for . The gas valv e may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degr ees above ambient temperature. Problem with gas valv e. • Use a DC voltmete[...]
-
Page 39
39 Reference Number Part Description Part Number 1 T op V ent Insert Piece - P ainted EGWP-503 1 T op V ent Insert Piece - Antique White EGWP-503A W 1 T op V ent Insert Piece - Diamond Black EGWP-503DB 1 T op V ent Insert Piece - Inferno R ed EGWP-503IR 1 T op V ent Insert Piece - P earl Grey EGWP-503PG 1 T op V ent Insert Piece - W edgewood B lue [...]
-
Page 40
Reference Number Part Description Part Number 5 Side P anel (Right) - P ainted EGWP-505 5 Side P anel (Right) - Antique White EGWP-505A W 5 Side P anel (Right) - Diamond Black EGWP-505DB 5 Side P anel (Right) - Inferno R ed EGWP-505IR 5 Side P anel (Right) - P earl Grey EGWP-505PG 5 Side P anel (Right) - W edgewood Blue EGWP-505WB 5 Side P anel (Ri[...]
-
Page 41
Reference Number Part Description Part Number T op Complete ( T op, V ent Insert, & Grate) - P ainted EGWP-501 T op Complete ( T op, V ent Insert, & Grate) - Antique White EGWP-501A W T op Complete ( T op, V ent Insert, & Grate) - Diamond Black EGWP-501DB T op Complete ( T op, V ent Insert, & Grate) - Inf erno Red EGWP-501IR T op Co[...]
-
Page 42
42 P ar ts Diagr am - Cast 1 2 3 4 5 7 6 8 WESTPORT - Castings January 2005[...]
-
Page 43
P ar ts List - Components Reference Number Part Description Part Number 9 120° Cer amic F an T emperature Sensor EC -001 10 S.I.T . Nova V alve Con vertible 50-1421 11 Thermocouple EC -009 11 Spark Electrode with Ignitor Cable EC -011 11 Thermopile EC -012 11 Pilot Orice NG Threaded EC -019 11 Pilot Orice LP Threaded EC -020 Pilot Gasket EC [...]
-
Page 44
P ar ts List - Components Reference Number Part Description Part Number 19 Inner Door Handles (2 per set) 30-052 20 V enturi Adjustment Rod 30-053 21 Firebox 30-054 22 P an Burner Only 30-055 23 45° Elbow & Gasket 50-040 24 F an Kit 180 C.F .M. 50-173 Door Knob - Brushed Nickel 50-262 Electronic Ignition Module S witch 50-329 25 Blank Orice[...]
-
Page 45
45 P ar ts Diagr am - Components 13 17 16 10 27 15 26 24 9 22 11 21 25 29 20 14 19 23 12 28 18 WESTPORT - Components January 2005[...]
-
Page 46
46 W arr anty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest lev el of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the nest materials and is backed by our Exclusive Lifetime Limit[...]
-
Page 47
47 caused by mechanical systems such as furnaces, f ans, clothes dryers etc. 12. The Limited W arrant y is void if: a) The stove has been oper ated in atmospheres contaminated by chlorine, uorine or other damaging chemicals. b) The stove is subject to submersion in w ater or prolonged periods of dampness or condensation. c) Any damage to the uni[...]
-
Page 48
48 Inst alla tion Da t a Sheet The following information must be recorded by the installer for warrant y purposes and futur e reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:_______________[...]