Go to page of
Similar user manuals
-
Stove
Enviro Meridian C-10135
38 pages 3.02 mb -
Stove
Enviro 1200 Freestanding
45 pages 2.94 mb -
Stove
Enviro 1200 Fireplace Insert
45 pages 2.94 mb -
Stove
Enviro EG 40 B
20 pages 0.91 mb -
Stove
Enviro C-10969
12 pages 0.58 mb -
Stove
Enviro Kodiak 1200 Fireplace Freestanding
50 pages 5.44 mb -
Stove
Enviro EP3
14 pages 1.03 mb -
Stove
Enviro 50-1675
16 pages 0.89 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Enviro EG 40 B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enviro EG 40 B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Enviro EG 40 B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Enviro EG 40 B should contain:
- informations concerning technical data of Enviro EG 40 B
- name of the manufacturer and a year of construction of the Enviro EG 40 B item
- rules of operation, control and maintenance of the Enviro EG 40 B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enviro EG 40 B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enviro EG 40 B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enviro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enviro EG 40 B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Enviro EG 40 B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SHERWOOD INDUSTRIES IS AN ENVI RONMENTALLY RESPO NSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER EG 40 B Vented By SHERWOOD INDUSTRIES LTD. OWNERS MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your[...]
-
Page 2
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: GENERAL • Installation and repair should be do ne by a qualified service person. The appliance should be inspected before u se and at once least annually by a qualified service person. More freque nt cleani[...]
-
Page 3
3 TABLE OF CONTENTS Safety Precautions 2 Code Approvals 3 Deciding where to locate y our stove 4 Venting 6 Installation of Log Sets and Embers 8 Operating Instructions 9 Maintenance and Technica l 10 Trouble Shooting 11 Gas Line Connection 12 Electrical 13 Parts and Ac cessories 14 Fuel Type Conversion 15 Warranty 16 Parts List 17 Exploded views 18[...]
-
Page 4
DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: FIG. 1 Front Width: 25"/ 63 cm Rear Width: 25"/ 63 cm Height: 29"/ 74 cm* Depth 21"/ 53 cm ( *not including vent coupling ) Shipping Weight: 256 lbs/116 kg CLEARANCES: A. Side wall to stove 12"/ 30cm B. Rear wall to stove 4"/ 10cm C. Combustible to stove Top 36”/ 91cm D[...]
-
Page 5
VENT TERMINAL CLEARANCES A= Clearance above grade, verandah, porch, deck, or [balcony (*12 inches (30cm ) minimum] B= Clearance to window or door that ma y be opened [*12 inches (30cm) minimu m] C= Clearance to perma nently closed window [minimum 12 inches (30cm) recomm ended to prevent condensation on window] D= Vertical clearance to ventilated so[...]
-
Page 6
VENTING This model must have a vent opening in the r ear of the unit. C onfirm this and als o check that the label on the right side pa nel door states "Vented Room Heater". WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AI R FROM THE ROOM. THE DRA FT HOOD LOCATED IN THE SAME ATMOSP HERIC PRESS[...]
-
Page 7
A. USING AN EXISTING CHIMNEY • Measure the height of the chimney beforehand and purchase the appropriate kit. Never attempt to over stretch a flexible liner to accommodate the height of the chimney. • Any flue damper must be removed or locked perman ently in the open position. • The chimney must be clean, in good wo rking order and constructe[...]
-
Page 8
INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBE RS A bag of ceramic fiber embers is provide d for use on the front burner ember tray. CAUTION: Use only the type of ember material supp lied wi th this appliance. Due to the irregular size of the ember material there may be more than requi red. Use only a single layer. Do not pile ember[...]
-
Page 9
OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATIN G WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCT IONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE. A) This applianc e is equipped with a pilot, which must be lit by hand by following these instructions exactly. B) BEFORE LIGHTING smell al[...]
-
Page 10
MAINTENANCE AND TECHNICAL Annually check to ensure that your Vent system is clear. Periodically check the pilot and burner. Che ck to see that all the burner port s are clean and clear. Check the pilot head for blockag e. Check to ensure the pilot flame is blue with small yellow tips. CLEANING OF GLASS Do not clean glass w hen hot It will be necess[...]
-
Page 11
TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of sp ark igniter Defective piezo igniter Check connection s to igniter -If igniter connections are good but there is no spark-replace igniter Broken spark electrode -Check for broken cerami c insulation replace, electrode if broken Miss-aligned [...]
-
Page 12
GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS FRONT BURNER #48 (1.93mm) #55 (1.32mm) REAR BURNER #41 (2.49 mm) #54 (1.40 mm) Manifold pressure. 3.8” wc (.95 kPa) 11” wc (2.74 kPa) Min. Manifold pressure. 1.1” wc (.27 kPa) 2.7” wc (.67 kPa) Supply Pressure. 7.0” wc (1.74 kPa) 12” wc (2.98 kPa) Min. Suppl[...]
-
Page 13
ELECTRICAL The ENVIROGAS EG 40.FS.BV. will operate with no external po wer supply. These models have a Milli volt gas control which uses the pilot flame to generate enoug h electricity to operate the main burner. The appliance when install ed, must be electrically connecte d and grounded in accordan ce with local codes or in the absence of local co[...]
-
Page 14
PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve Piezo Igniter Burner Switch B-vent Spill switch 220 ° Orifice Blank Convection Blower Light Bulb Holder Light Switch (momentary) Fan Controller Log Se[...]
-
Page 15
• There is a separate air shutter for each burner. • Remove one screw from the cover pl ate located below the ash shelf. Loosen the other scre w (do not remove) swing the cover plate out of the way and tighten screw do wn to hold it in place. • With along screwdriver rotate spring clips to open or close the shutter to the desired setting. •[...]
-
Page 16
16 WARRANTY Sherwood Industries Ltd. offers a *Lifetime Wa rranty on this gas produc t. The lifetime warranty covers the appliance for a period of seven years fro m the date of installation. This warranty applies only to the original own er in the original location Covered under the lifetime warranty are Cabi net Sides, Tops, Pedestals, Surround Pa[...]
-
Page 17
17 PARTS LIST EC-001 120 ° F CERAMIC TEMP SENSOR EG40-081 UPPER GOLD BARS (SET of 2) EC-003 300 ° F CERAMIC SPILL SWITCH EG40-084 FS LOWER GOLD BAR EC-006 S.I.T. NOVA VALVE NG EG40-086 FS SIDE PANEL EC-007 S.I.T. NOVA VALVE LP EG40-087 BV STOVE TOP EC-008 THERMO COUPLE POST (10,00) EG40-088 FIREBOX BAFFLE EC-011 SPARK ELECTRODE W/ IGNITER WIRE EG[...]
-
Page 18
18 EG 40 DOOR AND BURNER ASSEMBLIES EXPLODED Page 1 of 2 JULY 2001 GLASS EXTRUSIONS DOOR LATCH STRIP HINGE SET OF 2 EG40-302 PAINTED DOOR ASSEMBLY WITH GLASS (A + B) EG40-073 GOLD DOOR ASSEMBLY WITH GLASS (A + B) EG40-075 GLASS RETAINER 3 PIECE GLASS WITH GASKET EG40-205 DOOR LATCH BOLT EC-059 OUTER DOOR PAINTED OR GOLD (DOOR A) EG40-074 , 076 INNE[...]
-
Page 19
19 FS UPPER BAR SET EG40-081 EG 40 FREESTANDING BODY (chassis) EXPLODED. Page 2 of 2 JULY 2001 EG 40 EMBLEM FS PEDESTAL DOOR EG40-135 FS ASH SILL EG40-213 FS LOWER BAR EG40-084 CONVECTION AIR DEFLECTORS EG40-033 FS SIDE PANEL CABINET EG40-049 1 X 1 SIDE CABINET HINGE EC-054 FS STOVE TOP (BV or DV) EG40-087 FLUE PIPE 120 ° F (49 ° C) FAN TEMP SENS[...]
-
Page 20
INSTALLATION DATA SHEET The following information must be recorded by the in staller for wa rranty purposes and future reference. Model: EG 40 20 Name of Dealer: _______________ ____________ _______________ _ Address: _______________ ____________ _______________ _ _______________ ____________ _______________ _ _______________ ____________ _________[...]