Enviro EG40-070 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Enviro EG40-070, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enviro EG40-070 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Enviro EG40-070. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Enviro EG40-070 should contain:
- informations concerning technical data of Enviro EG40-070
- name of the manufacturer and a year of construction of the Enviro EG40-070 item
- rules of operation, control and maintenance of the Enviro EG40-070 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enviro EG40-070 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enviro EG40-070, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enviro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enviro EG40-070.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Enviro EG40-070 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EG40-070 SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE E G 4 0 D V This appliance may be installed in an after market permanently located, manufactured (mobile) home, wher e not prohibit[...]

  • Page 2

    2 FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIRO” HEA TER, PLEASE CAREFULL Y READ THE FOLLOWING INFORMA TION: • All ENVIRO gas-red appliances must be instal led in accor dance with their instructions. Caref ully r ead all the instructions in this manual rst. Consult the building authority having jurisdiction to determine the ne[...]

  • Page 3

    3 T able of Contents Safety Precautions..........................................................................................2 T able of Contents............................................................................................3 Codes And Approvals............... .......................................................................4[...]

  • Page 4

    DIRECT VENT: This type is identied by the sufx DV . This appliance draws all of its air for combustion from outside the dwelling, through a specially designed v ent pipe system. This appliance has been tested and approved f or installations from 0 ft to 4500 ft (1372 m) abov e sea level. In the USA: The appliance may be installed at higher al[...]

  • Page 5

    5 Specific a tions D IMENSIONS : 25" (635 mm) 21" (533 mm) 12 1 / 2 " (318 mm) 4 5 / 8 " (1 17 mm) 29 1 / 8 " (740 mm) Shipping Weight 256 lbs (1 16 kg) Figure 1: EG40 Exterior Dimensions. R ATING L ABEL L OCATION : The rating label is f ound inside the right cabinet side panel.[...]

  • Page 6

    Oper a ting Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. L IGHTING I NSTRUCTIONS : 6 1. STOP! Read the safety information above on this label. 2. T urn off all electrical power to this appliance. 3. T urn off the gas control knob clockwise to the off position. 4. Open door . Wait fIve (5) minutes to clear out any gas. Close door .[...]

  • Page 7

    Thermopile Thermocouple Figure 4: Gas Valve. Figure 3: Pilot Burning. 7 • There is a separate venturies for each burner , see Figure 5. • Remo ve one screw from the cover plate located below the ash shelf and loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold i t in place. • With along s[...]

  • Page 8

    8 Maintenance and Ser vice Annually check to ensure that your V enting system is clear . P eriodically check the pilot and burner . Check to see that al l the burner ports are clean and clear . Check the pilot head for blockage. Check to ensure the pilot ame is blue with no or very small yellow tips. O PENING T HE D OOR : T urn unit off and wait[...]

  • Page 9

    9 Figure 8: Blower (Fan) Removal. 1. T urn the unit off , allow it to cool down completely , and remove the door as shown in the M AINTENANCE AND S ERVICE - O PENING T HE D OOR .. 2. Remo ve the log set and brick liner . 3. R emove the burner tr ay assembly , see M AINTENANCE AND S ERVICE - B URNER R EMOV AL . 4. Remove the four (4) 5 / 16 ” bolt[...]

  • Page 10

    Maintenance And Ser vice F UEL C ONVERSION : Figure 9: Removing valve cap. a) R emove the main burner orice with a  inch deep sock et. b) Put a bead of pipe-thread sealant or approved T eon tape on the orice threads before installing into the br ass elbow. c) Install the new orice(s) fr om the kit into the brass elbow . 6. Conv ert t[...]

  • Page 11

    11 Maintenance And Ser vice b) Insert a 5 / 32 ” or 4 mm Al len wrench into the hexagonal key -wa y of the screw (see Figure 10), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt. d) Flip the screw (refer to Figur e 11). e) Using the Allen wrench as shown in Figure 10, rota[...]

  • Page 12

    Initial Inst alla tion QUALIFIED INST ALLERS ONL Y WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. P REPARATION F OR I NSTALLATION : • Remov e the packaging from the appliance, and check to make sure there is no damage. If d[...]

  • Page 13

    Vertical Termination Storm Collar Flashing Round Support Box/Wall Thimble Ceiling Firestop Pipelength Pipelength Cathedral Ceiling Support Box Pipelength Round Support Box/Wall Thimble Pipelength Horizontal Termination 90° Elbow P LANNING Y OUR I NSTALLATION : When planning your installation, it will be necessary to select the proper length of ven[...]

  • Page 14

    14 M OBILE H OME I NSTALLATION : • When the unit is installed in a Mobile Home it must be grounded to the steel chassis or connected to a grounding rod. • In a Mobile Home installation the unit must be bolted securely to the oor using the holes provided (see Figure 17). • Manufactured (mobile) home installation must be in accordance with t[...]

  • Page 15

    1 In accordance with the current CSA B149, Natur al Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFP A 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the r equirements of the gas supplier . t A vent shall not terminate directly above a side w alk[...]

  • Page 16

    16 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y   Figure 19: Wire Spacers. it to the inner wall frame using four (4) 1” wood screws. If a wall is greater than 8” (203mm) in depth, the clearance above the ex must be 4” (111mm) 6. Apply a bead of Mill-P ac Black sealant to the new Ø4” (10 cm) b[...]

  • Page 17

    Flue Pipe Adaptor W all Framing W all Thimble Fire Stop Exhaust 4" Flex Pipe Combusion Air 6 5 / 8 " Flex Pipe Wire Spacers Horizontal V ent T ermination Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Figure 21: Installation of Fireplace Horizontal Vent Kit. 10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” ([...]

  • Page 18

    18 EXCEPTION T O W ARNING: This product has been evaluated by Intertek for using a Direct V ent GS starting collar in conjunction with Secure V ent, Direct - T emp, and Ameri V ent Direct venting systems. Use of these systems with the Direct V ent GS starting collar is deemed acceptable and does not af fect the Intertek WH listing of the appliance.[...]

  • Page 19

    Figure 23: Vent restrictor ring. Figure 22. Possible Vent Congurations; Vertical and Horizontal Terminations. V ENT C ONFIGURATIONS : Figures 22 shows the range of venting options, it shows possible vent congurations if the unit is top vented, for vertical and horizontal terminations, any layout that remains within the shaded area is acceptab[...]

  • Page 20

    20 H ORIZONTAL I NSTALLATION : 1. Set the appliance in the desired location. Check to determine if wall studs or roof r afters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance. 2. Direct vent pipe and ttings are designed with special twist-lock connections. Assemble the[...]

  • Page 21

    wall thimble will conceal it (see left image in Figure 26). 7. Slide the decorative wall thimble up to the wall surface and attach with the screws pro vided. Apply decorative brass or chrome trim if desired (see right image in Figure 26). NOTES: • The four wood screws provided should be replaced with the appropriate fasteners for stucco, brick, c[...]

  • Page 22

    22 V ERTICAL I NSTALLATION : 1. Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. Do not pack air spaces with insulation. 1 1 / 2 ” (4cm) long wood screw (x4) 10” (25.4cm) x 10” (25.4cm) inside framing Ceilin[...]

  • Page 23

    support straps to the roof . Seal the nails holes heads with non-hardening mastic. T rim the excess length of the support straps that extend out bey ond the edge of the ashing. 7. Slip the ashing ov er the pipe section protruding through the roof . Secure the base of the ashing to the roof with roong nails. Use a non-hardening sealant b[...]

  • Page 24

    24 Nails Ceiling firestop Ceiling Second floor Use clearances to as defined by appliance and vent pipe manufacturers. • For multi story installations. A ceiling restop is required at the second oor , and any subsequent oors (see Figure 33). The opening should be framed to 10” (25.4 cm) x 10” (25.4 cm) inside dimensions, in the same m[...]

  • Page 25

    25 V ENTING INTO A C LASS ‘A’ C HIMNEY : This model is also certied and tested to vent into CL ASS ‘ A ’ wood stove chimneys. Place the freestanding direct v ent appliance in the desired location. Use a conversion kit from Simpson Dur avent (931, 932, or 933), or Security Chimney (SV4CCK1, SV4CCK2, or SV4CCK1). Which kit is used will dep[...]

  • Page 26

                                          [...]

  • Page 27

    Initial Inst alla tion G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certied exible pipe located on the right side of the unit terminating in a ” male NPT tting. Consult y our l[...]

  • Page 28

    CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. The use of other for eign materials on the burners may create dangerous conditions. If over time, through cleaning and servicing, these embers require replacement, contact the nearest ENVIRO dea[...]

  • Page 29

    29 Second ar y Inst alla tion CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. Place the log set into the rebox. Locate each log by seating it down onto the burner tray support pins. F ollow Figures 31 to 34 proper log placement. Upon the rst light up, watch for ignition to ALL burner ports. If a long delay is noted: First, [...]

  • Page 30

    T rouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for . The gas valv e may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degr ees above ambient temperature. Problem with gas valv e. • Use a DC v oltmeter [...]

  • Page 31

    31 P ar ts List Reference Number Part Description Part Number 1 120 °F (49 °C) Ceramic T emperature Sensor EC-001 2 S.I.T . NOV A V alve Convertible 50-1421 3 Thermocouple EC-009 3 Spark Electrode with Ignitor Cable EC-01 1 3 Thermopile EC-012 3 Fully Assembled Pilot NG EC-015 3 Fully Assembled Pilot LP EC-016 3 Pilot Orice NG Threaded EC-019 [...]

  • Page 32

    P ar ts List Reference Number Part Description Part Number 14 Side Panel EG40-086 15 DV Stove T op EG40-087A Firebox Bafe EG40-088 Stove T op Bafe DV EG40-091A V enturi Cover Plate EG40-097 16 Front V enturi EG40-098 17 Bar Set - Painted (3 pieces) EG40-1 14 17 Bar Set - Gold (3 pieces) EG40-1 15 17 Bar Set - Nickel (3 pieces) 50-478 Burner G[...]

  • Page 33

    33 P ar ts Diagr am - Chas sis             EG 40 Body (Chassis) July 2004[...]

  • Page 34

    P ar ts Diagr am - Gas T r a y & Door EG40 Gas Tray & Door Assemblies July 2004 27 8 20 9 23 2 4 5 10 6 11 16 26 25 24 3 34[...]

  • Page 35

    35 W arr anty Sherwood Industries Ltd. offers a Limited Lifetime W arrant y on this gas product. This limited lifetime warrant y covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the lifetime warrant y are Cabinet Sides, T ops, Pede[...]

  • Page 36

    36 Inst alla tion Da t a Sheet The following information must be recorded by the installer f or warr anty purposes and f uture reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:______________[...]