Go to page of
Similar user manuals
-
Heat Pump
Envision Peripherals Series
36 pages 1.66 mb -
Heat Pump
Envision Peripherals IM1609 10
48 pages 3.26 mb -
Heat Pump
Envision Peripherals R-410A
40 pages 1.26 mb -
Heat Pump
Envision Peripherals IM1609 08
48 pages 3.26 mb -
Heat Pump
Envision Peripherals Geothermal Indoor Split Heat Pumps
36 pages 2.17 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Envision Peripherals R-410A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Envision Peripherals R-410A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Envision Peripherals R-410A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Envision Peripherals R-410A should contain:
- informations concerning technical data of Envision Peripherals R-410A
- name of the manufacturer and a year of construction of the Envision Peripherals R-410A item
- rules of operation, control and maintenance of the Envision Peripherals R-410A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Envision Peripherals R-410A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Envision Peripherals R-410A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Envision Peripherals service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Envision Peripherals R-410A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Envision Peripherals R-410A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
IM1585 10/07 Installation Information W ater Piping Connections Desuperheater Connections Electrical Startup Procedures T roubleshooting Preventive Maintenance Geothermal/W ater Source Heat Pumps • R-410A Refrigerant • 2, 2.5, 3, 3.5, 4, 5, 6 T on Single Speed • 2, 3, 4, 5, 6 T on Dual Capacity Envision Residential Installation Manual RESIDEN[...]
-
Page 2
2 ENVISION RESIDENTIAL INST ALLA TION MANUAL Model Nomenc la ture N D V 049 A 1 1 1 C T L Model T ype Return Air Configuration N= Envision L= Left R= Right Compressor T ype D= Dual Capacity Discharge Air Configuration S= Single Speed B= Bottom T= T op Cabinet Configuration S= Side V= V ertical E= End H= Horizontal Coax Options Unit Capacity C= Copp[...]
-
Page 3
3 ENVISION RESIDENTIAL INST ALLA TION MANUAL T able of Contents General Installation Information 4-8 Closed Loop Ground Source Systems 9 Open Loop Ground W ater Systems 10 Desuperheater Connection & Startup 1 1-12 Electrical Connections 13-14 Electronic Thermostat Installation 14 Auxiliary Heat Ratings 14 Electrical Data 15 Fan Performance T ab[...]
-
Page 4
4 ENVISION RESIDENTIAL INST ALLA TION MANUAL Mo ving and Stora ge Move units in the normal “up” orientation. Horizontal units may be moved and stored per the information on the packag- ing. Do not stack more than three units in total height. V ertical units may be stored one upon another to a maximum height of two units. Do not attempt to move [...]
-
Page 5
5 ENVISION RESIDENTIAL INST ALLA TION MANUAL Installing Hori zontal Units Remov e and discard the c ompressor hold down shipping b olt located at the front of the c ompressor mounting bracket prior to set ting the unit in plac e. Horizontal units are available with side or end discharge. Hor izontal units are nor mally su s- pended from a c eiling [...]
-
Page 6
6 ENVISION RESIDENTIAL INST ALLA TION MANUAL Duct Sys tem An air outl et collar is provided on ver tic al top air discharge units and all hor izontal units to facilit ate a duct connec tion (ve r t i c a l b ot to m fl ow units hav e no co llar ). A fl e xible c onnector is rec ommended for discharge and return air duc t connec - tions on metal d[...]
-
Page 7
7 ENVISION RESIDENTIAL INST ALLA TION MANUAL Water Qualit y In ground water situations where scaling could be heav y or wh ere biologic al grow th such as iron bac teria will be pres - ent, a closed loop system is recommende d. The heat e xchanger coils in ground water s ystems may , ov er a perio d of time, lose heat ex change capabilities due to [...]
-
Page 8
8 ENVISION RESIDENTIAL INST ALLA TION MANUAL 1/2'' Pitch Drain 1.5" 1.5" 3/4” PVC tube stub 3/4" PVC Coupling V ent (if needed) 3/4" PVC 1/8" per foot Figur e 6: Unit Pit ch fo r Dra in Figur e 5: Hor iz ont al D rain C onn ec tio n F reez e Protecti on Set the freeze sensing switch SW2- 2 on the printed circ ui[...]
-
Page 9
9 ENVISION RESIDENTIAL INST ALLA TION MANUAL Figu re 7 : Clos ed Loo p Gro und S ourc e Ap pl ica ti on Closed Loop Ground Source S ystems Note: For closed loop systems with antifreeze protection, set SW2-2 to the “loop” position (see table on page 28). Once piping is completed between the unit, pumps and the ground loop (see fi gure below), ?[...]
-
Page 10
10 ENVISION RESIDENTIAL INST ALLA TION MANUAL Ope n Loop Ground W ater Systems T ypical open loop piping is shown below . Always maintain water pressure in the heat exchanger by placing water control valves at the outlet of the unit to prevent mineral precipitation. Use a closed, bladder-type expansion tank to minimize mineral formation due to air [...]
-
Page 11
11 ENVISION RESIDENTIAL INST ALLA TION MANUAL Desuper heater Connections To m a x i m i z e t h e b e n e fi ts of the desuper heater a minimum 50 - gallon water heater is recommended. For higher demand applications, use an 8 0 -gallon water heater or two 50 -gallon water heaters c onnected in a seri es as shown b e l o w. E l e c t r i c w a t e [...]
-
Page 12
12 ENVISION RESIDENTIAL INST ALLA TION MANUAL Plumbing Installation 1 . Inspect the dip tube in the water heater cold inlet for a check valve . If a check valve is present it must be remo ved or damage to the desuperheater circulator will oc cur . 2. Remove drain valv e and fi tti n g . 3. Thread the 3 /4- inch NPT x 3 - 1/2 -inc h brass nipple in[...]
-
Page 13
13 ENVISION RESIDENTIAL INST ALLA TION MANUAL Electrical Connections General Be sure the available power is the same voltage and phase as that shown on the unit serial plate. Line and low voltage wiring must be done in accordance with local codes or the National Electric Code, whichever is applicable. Unit P o wer Connection Connect the incoming li[...]
-
Page 14
14 ENVISION RESIDENTIAL INST ALLA TION MANUAL Auxiliar y Hea t Ra tings KW BTU/HR Min Envision Series Compatibility Model 208V 230V Stages 208V 230V CFM 022 026 - 030 036 - 049 060 - 072 EAM(H)5 3.6 4.8 1 12,300 16,300 450 •• EAM(H)8 5.7 7.6 2 19,400 25,900 550 •• EAM(H)10 7.2 9.6 2 24,600 32,700 650 • EAL(H)10 7.2 9.6 2 24,600 32,700 1 1[...]
-
Page 15
15 ENVISION RESIDENTIAL INST ALLA TION MANUAL Unit Electrical Da ta Single speed with ECM motor HWG Ext Fan T otal Min Max Pump Loop Motor Unit Circ Fuse/ MCC RLA LRA FLA FLA FLA FLA Amp HACR 14.0 9.0 48.0 0.4 5.4 4.0 18.8 21.0 30 20.0 12.8 58.3 0.4 5.4 4.0 22.6 25.8 35 22.0 14.1 73.0 0.4 5.4 4.0 23.9 27.4 40 22.0 14.1 73.0 0.4 5.4 7.0 26.9 30.4 40[...]
-
Page 16
16 ENVISION RESIDENTIAL INST ALLA TION MANUAL Setting F a n Speed - PSC CA UTIO N: Discon nec t all power b efor e per formi ng th is opera tion. F an P erfor mance Data - PSC PSC F AN MOTOR BODY HIGH LOW MEDIUM F A N S P E E D W I R E Fan Blower Motor Airflow (cfm) at External Static Pressure (in. wg) Model Spd Size HP 0 0.05 0.10 0.15 0.20 0.25 0[...]
-
Page 17
17 ENVISION RESIDENTIAL INST ALLA TION MANUAL Setting F a n Speed - ECM ECM2 fan motors have a 12-speed selector dip switch on the logic board (SW1) and are factory set for optimum perfor- mance. T o change speeds, select the appropriate speeds on dip switch SW1. Consult the ECM2 fan performance table below for speci fi c air fl ow and switch inf[...]
-
Page 18
18 ENVISION RESIDENTIAL INST ALLA TION MANUAL V er tical Dimensional Data T op Air Disc har ge LEFT RETURN RIGHT RETURN FRONT TOP 2ft [ 61cm ] Primary Service Access TOP A DEHF KJ I G 1.9in [4.8cm] 1.9in [4.8cm] M R Q N O L R N O L P Q RIGHT SIDE B C B LEFT SIDE S T S T C Overall Cabinet Water Connections Electrical Knockouts Return Connection V er[...]
-
Page 19
19 ENVISION RESIDENTIAL INST ALLA TION MANUAL Horizontal Dimensional Da ta 2ft [ 61cm ] Primary Service Access B C 2.1in [ 5.4cm ] H L O N M S R Q P MOUNT (2) HANGER BRACKET S AS SHOWN TO ALLOW ACCES S TO FILTER AS SHOW N LR UNIT (RR UN IT ON OPPOSITE SIDE—SAME DIMENSIONS) SIDE DISHCARGE VIEW END VIEW TOP VIEW A S FRONT VIEW DE F G KJ I 1.9in [4.[...]
-
Page 20
20 ENVISION RESIDENTIAL INST ALLA TION MANUAL V er tical Dimensional Data 2 f t [6 1 c m] Primary Service Access LEFT SIDE RIGHT SIDE B C S T B C S T LEFT RETURN RIGHT RETURN RQ L N O P A FRONT D E F G H I J K 1.90 (4.7 cm) 1.70 (4.3 cm) 1 2 3 4 5 RIGHT BOT TOM DISCHARGE FLOOR FOOT PRINT R O N L M LEFT BOTTOM DISCHARGE FLOOR FOOT PRINT Q Ret ur n C[...]
-
Page 21
21 ENVISION RESIDENTIAL INST ALLA TION MANUAL 022 030 036 042 048 060 070 Compressor (1 each) Factory Charge R410a, oz [kg] V ertical 62 [1.76] 62 [1.76] 82 [2.32] 82 [2.32] 98 [2.78] 1 10 [3.12] 146 [4.14] Factory Charge R410a, oz [kg] Horizontal 60 [1.70] 66 [1.87] 82 [2.32] 82 [2.32] 98 [2.78] 94 [2.67] 122 [3.46] Fan Motor & Blower ECM PSC [...]
-
Page 22
22 ENVISION RESIDENTIAL INST ALLA TION MANUAL Notes: Sizes 038, 049 available with 1HP blower motor (ICM only). 026 038 049 064 072 Compressor (1 each) Copeland 2-speed Scroll, UltraT ech Factory Charge R410a, oz [kg] V ertical 62 [1.76] 78 [2.21] 89 [2.52] 122 [3.46] 140 [3.97] Factory Charge R410a, oz [kg] Horizontal 60 [1.70] 76 [2.16] 89 [2.52][...]
-
Page 23
23 ENVISION RESIDENTIAL INST ALLA TION MANUAL C HWL HP Thermostat CO R C Y1 O L1 Y2 NOTE 4 G LP PS FP W Brn(15) Org(14) 1 2 3 P10 4 5 Envision - Single Speed Wiring Schematic - 208-230/60/1 97P774-06 9/27/06 PB2 Auxiliary Electric Heat Power 208-230/60/1 With optional ' EA' Series Auxiliary ElectricHeat Typical schematic shown 2 3 HE1 TS1[...]
-
Page 24
24 ENVISION RESIDENTIAL INST ALLA TION MANUAL W iring Sc hema tics En vision - Single Speed W iring Schematic - 208-230/60/1 - ECM C HWL HP Thermostat CO R C Y1 O L1 Y2 NOTE 4 G LP PS FP W Brn(15) Org(14) 1 2 3 P10 4 5 97P774-01 6/29/06 Org Brn NOTE 2 6 Blk/Wht(11) Gry/Wht(10) SL1 In SL1 Out Optional Remote Unit Without Loop Pump Status LED PCB SW4[...]
-
Page 25
25 ENVISION RESIDENTIAL INST ALLA TION MANUAL PB2 Auxiliary Electric Heat Power 208-230/60/1 Violet Blu With optional ' EA' Series Auxiliary ElectricHeat Typical schematic shown 2 3 HE1 TS1 HE2 TS2 HE3 TS3 HE4 TS4 P7 L4 L2 L2 NOTE 5 Pink Yel Blk Gray Pink Yel Blk Gray Gray Blk Yel Pink Gray Pink Blk Yel Pink Yel Blk Gray Pink Yel Blk Gray[...]
-
Page 26
26 ENVISION RESIDENTIAL INST ALLA TION MANUAL W iring Sc hema tics En vision - Dual Capacity W iring Schematic - 208-230/60/1- ECM C S R C HWL HP Thermostat CO R C Y1 O L1 Y2 NOTE 4 G LP PS FP W Brn(15) Org(14) 1 2 3 P10 4 5 Org Brn NOTE 2 6 Blk/Wht(11) Gry/Wht(10) SL1 In SL1 Out Optional Remote Unit Without Loop Pump Status LED PCB SW4 R R R R R G[...]
-
Page 27
27 ENVISION RESIDENTIAL INST ALLA TION MANUAL PB2 Auxiliary Electric Heat Power 208-230/60/1 Violet Blu With optional ' EA' Series Auxiliary ElectricHeat Typical schematic shown 2 3 HE1 TS1 HE2 TS2 HE3 TS3 HE4 TS4 P7 L4 L2 L2 NOTE 5 Pink Yel Blk Gray Pink Yel Blk Gray Gray Blk Yel Pink Gray Pink Blk Yel Pink Yel Blk Gray Pink Yel Blk Gray[...]
-
Page 28
28 ENVISION RESIDENTIAL INST ALLA TION MANUAL Star tup The unit will not operate until all the inputs and safety controls are checked for normal conditions. At fi rst power-up, a four-minute delay is employed before the compressor is energized. Component Sequencing Delays Components are sequenced and delayed for optimum space conditioning performa[...]
-
Page 29
29 ENVISION RESIDENTIAL INST ALLA TION MANUAL Micr opr ocessor Control (cont.) Heat, 3rd Stage (Y1,Y2,W) Dual Capacity Units The hot water pump is de-energized which directs all heat to satisfy the thermostat. The 1st stage of resistance heat is energized 10 seconds after “W” input, and with continuous 3rd stage demand, the additional stages of[...]
-
Page 30
30 ENVISION RESIDENTIAL INST ALLA TION MANUAL Green "POWER" LED - module has power Red "TRIP" LED - Thermostat "Y" demand signal is present, but the compressor is not running. Y ellow "ALERT" LED LED Description Cause Flash Code 1 Long Run Time Eighteen consecutive hours of compressor run time Flash Code 2 Sy[...]
-
Page 31
31 ENVISION RESIDENTIAL INST ALLA TION MANUAL The following tables show the codes that will be displayed on the different ComforT alk and FaultFlash thermostats. FaultFlash Thermostats ComforT alk Thermostats Thermostat Display Lockout Code Thermostat Display Lockout Code Lockout Description Lockout Description 2 Flashes High Pressure Fault "H[...]
-
Page 32
32 ENVISION RESIDENTIAL INST ALLA TION MANUAL DIP Switch Settings Prior to powering unit, ensure that all DIP switches on SW2 & SW3 are set properly according to the tables below . F ACTOR Y SETUP DIP SWITCHES (SW3) DIP SWITCH NUMBER DESCRIPTION OFF POSITION ON POSITION SW 3- 1 Dual Capacity/Single-Speed Con fi gures the control for single-spe[...]
-
Page 33
33 ENVISION RESIDENTIAL INST ALLA TION MANUAL High voltage is cor rect and matches nameplate. F uses, breakers and wire size cor rect. Low voltage wir ing complete. Piping completed and water sy stem cleaned and fl ushed. Air is purged f rom closed loop system. Isolation valv es are open, wat er co ntrol valv es or loop pumps wired. Condensate lin[...]
-
Page 34
34 ENVISION RESIDENTIAL INST ALLA TION MANUAL Oper a tion Logic Da ta OPE R A TI ON LO GI C HEA TING C OOLING F AN O N SL 1 - IN ON STG 1 STG2 STG3 EME RG STG1 STG2 SINGLE SP EED UNITS Compressor On On On Of f On On - - ECM2 No r mal Med High High H igh Med High Low - ECM2 D ehu mid if y Med High High High 8 5% Med 8 5% High Low - PSC On On On On O[...]
-
Page 35
35 ENVISION RESIDENTIAL INST ALLA TION MANUAL Suction Pressure PSIG Discharge Pressure PSIG 022-070 Superheat 022-070 Subcooling W ater T emp Rise °F Air T emp Drop °F DB 1.5 133 - 148 205 - 225 17 - 26 10 - 14 18 - 22 18 - 22 3.0 129 - 144 185 - 205 20 - 29 7 - 1 1 8 - 10 18 - 22 1.5 139 - 154 280 - 300 8 - 1 1 8 -12 18 - 22 18 - 22 3.0 137 - 15[...]
-
Page 36
36 ENVISION RESIDENTIAL INST ALLA TION MANUAL Suction Pressure PSIG Discharge Pressure PSIG Su p erheat Subcoolin g W ater T emp Rise °F Air T emp Drop °F DB 1.5 125-140 205-225 12-20 8-14 17-21 17-23 3.0 120-135 190-210 12-20 8-14 8-12 17-23 1.5 135-145 280-290 10-16 8-14 16-20 17-23 3.0 133-143 250-260 10-16 8-14 9-13 17-23 1.5 142-152 345-355 [...]
-
Page 37
37 ENVISION RESIDENTIAL INST ALLA TION MANUAL Pr essur e Drop Single Speed Models Dual Capacity Models 30°F 50°F 70°F 90°F 1 10°F 3.0 0.9 0.9 0.8 0.7 0.7 022 4.5 1.7 1.6 1.5 1.4 1.3 6.0 2.8 2.7 2.5 2.3 2.2 8.0 4.7 4.4 4.1 3.9 3.6 4.0 1.5 1.4 1.3 1.2 1.1 030 6.0 3.0 2.8 2.7 2.5 2.3 8.0 5.1 4.8 4.5 4.2 3.9 10.0 7.7 7.2 6.8 6.3 5.8 5.0 1.0 1.0 0.[...]
-
Page 38
38 ENVISION RESIDENTIAL INST ALLA TION MANUAL T roublesho oting Standard Microprocessor Controls T o check the unit c ontrol board for proper operation: 1 ) Disc onnect ther mostat wires at the control bo ard. 2 ) Jumper the desire d test input ( Y 1 , Y2, W , O or G ) to t he R terminal to simulate a thermost at signal. 3 ) If c ontrol functions p[...]
-
Page 39
39 ENVISION RESIDENTIAL INST ALLA TION MANUAL Preve nt i ve M a i nt e n a n c e Water Coil Maintenance 1. Keep all air out of the water . An open loop system should be checked to ensure that the well head is not allowing air to in fi ltrate the water line. Lines should always be airtight. 2. Keep the system under pressure at all times. It is reco[...]
-
Page 40
Manufactured by WFI 9000 Conservation W ay Fort W ayne, IN 46809 W aterFurnace has a policy of continuous product research and development and reserves the right to change design and speci fi cations without notice. ©2007 WFI. Product: Envision T ype: Geothermal/Water Source Heat Pumps Size: 2 thru 6 T on Single Speed 2 thru 6 T on Dual Capacity [...]