Ericsson IP DSLAM manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ericsson IP DSLAM, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ericsson IP DSLAM one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ericsson IP DSLAM. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ericsson IP DSLAM should contain:
- informations concerning technical data of Ericsson IP DSLAM
- name of the manufacturer and a year of construction of the Ericsson IP DSLAM item
- rules of operation, control and maintenance of the Ericsson IP DSLAM item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ericsson IP DSLAM alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ericsson IP DSLAM, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ericsson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ericsson IP DSLAM.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ericsson IP DSLAM item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EDN312 Installation Guide Ethernet DSL Access IP DSLAM[...]

  • Page 2

    EDN312 Installation Guide Ethernet DSL Access IP DSLAM . ii 1/1531-HSD 101 41 Uen A 2004-01-30 Copyright  Ericsson AB - 2004 All Rights Reserved Disclaimer No part of this document may be reproduced in any form without the written permission of the copyright owner. The contents of this document are subject to revision without notice due t o cont[...]

  • Page 3

    . 1/1531-HSD 101 41 Uen A 2004 -01-30 iii Contents 1 Introduction 1 1.1 Revision History 1 2 Environmental and Space Requirements 2 3 Cabling 4 3.1 Cabling of Subscriber Lines 4 3.1.1 Cabling Lines 4 3.1.2 Wiring EDGE Connectors 5 3.2 Cabling of Ethernet Connections 8 4 Mounting the IP DSLAM 9 5 Verifying the Installation 10 5.1 Verification withou[...]

  • Page 4

    [...]

  • Page 5

    Introduction 1/1531-HSD 101 41 Uen A 2004 -01-30 1 1 Introduction This guide describes how to install t he Ethernet DSL Access (EDA) IP DSLAM EDN312. The guide is intended for installation and maintenance personnel. An overview of the installation process of a complete Access Domain is described in the Access Domain Installation Guid e . The reader[...]

  • Page 6

    Environmental and Space Requirements 2 1/1531-HSD 101 41 Uen A 2004 -01-30 2 Environmental and Space Requirements The 12-line IP DSLAM (EDN312) complies with the following standards regarding storage, transportation and operation. The operation category is also designated stationary in-use at weather-protected locations. • ETS 300 019-2-1: Storag[...]

  • Page 7

    Environmental and Space Requirements 1/1531-HSD 101 41 Uen A 2004 -01-30 3 The distance between the IP DSLAMs must be at least 20 mm so that an IP DSLAM can be dismounted without interfering with the adjacent IP DSLAMs. Figure 1 Space Requirem ents when Mounting in Rack or Cabinet[...]

  • Page 8

    Cabling 4 1/1531-HSD 101 41 Uen A 2004 -01-30 3 Cabling 3.1 Cabling of Subscriber Lines Before the IP DSLAM is mounted the connections between the Line MDF and the Exchange MDF have to be rewired. The wires are disconnected, and then reconnected through typically a Broadband MDF and the EDA System according to planning. 3.1.1 Cabling Lines The foll[...]

  • Page 9

    Cabling 1/1531-HSD 101 41 Uen A 2004 -01-30 5 3.1.2 Wiring EDGE Connectors It is recommended to follow the “Best practice” wiring procedure when wiring the EDGE connectors. The EDGE connector can be mounted by using a Tool Kit. The kit consists of a wiring bracket-tool and an LSA+ inserter-tool. Figure 3 on page 5 shows how to mount the wiring [...]

  • Page 10

    Cabling 6 1/1531-HSD 101 41 Uen A 2004 -01-30 Figure 4 Mounting the EDGE Connectors Strip approximately 20 cm off the new cable and tie it up with a cable tie to the existing cable as illustrated in Figure 5 on page 7. Alternatively, make a loop around the cable guide. Note: It is recommended to use 0.4 mm thick wiring cables[...]

  • Page 11

    Cabling 1/1531-HSD 101 41 Uen A 2004 -01-30 7 Figure 5 Tie Up the New cable Connect and cut the wires (one action using the KRONE LSA+ Insertion- Tool S, see Figure 6 on page 7) by placing the Insertion tool above the slit (place the cutting end towards the connector’s center), and firmly press towards the connector. Repeat this step for all wire[...]

  • Page 12

    Cabling 8 1/1531-HSD 101 41 Uen A 2004 -01-30 Figure 7 Tie Up and Label the EDGE Connectors 3.2 Cabling of Ethernet Connections The EDN312 IP DSLAM is connected to the network with cat. 5 straight through standard LAN cables. The total cable length from a switch to the IP DSLAM must not exceed 100 m and must conform to category 5 standard for LAN c[...]

  • Page 13

    Mounting the IP DSLAM 1/1531-HSD 101 41 Uen A 2004 -01-30 9 4 Mounting the IP DSLAM The illustration below shows how to mount the EDN312 after the subscri ber lines, exchange lines through the EDGE connector have been pulled. The EDGE connector is removed from the bracket-tool and inserted in the rear of the IP DSLAM. The IP DSLAM has been labelled[...]

  • Page 14

    Verifying the Installation 10 1/1531-HSD 101 41 Uen A 2004 -01-30 5 Verifying the Installation The purpose of the verification is to ensure the following: • No errors in the rewiring of the subscriber lines • The old services (POTS or ISDN) function • The physical installation of the EDA Access Domain nodes was done correctly • The power an[...]

  • Page 15

    Verifying the Installation 1/1531-HSD 101 41 Uen A 2004 -01-30 11 5.2 V erification with the Local Craft T ool The LCT can be used without a connection to PEM or to any backbone network as described in section sect ion Error! Reference source not found. on page Error! Bookmark not defined. . The LCT activates the IP DSLAMs (as well as providing an [...]

  • Page 16

    Verifying the Installation 12 1/1531-HSD 101 41 Uen A 2004 -01-30 2. Copy 24 configuration files with line configurations from the LCT tool to the ECN320 flash disk. 3. Restart the embedded IP DSLAMs by using the Command Line Interface (CLI) 4. Test the ADSL lines by connecting a CPE modem to each line one at a time. The LCT has an SNMP Notificatio[...]

  • Page 17

    Verifying the Installation 1/1531-HSD 101 41 Uen A 2004 -01-30 13 This method is similar to activating real subscribe rs. In order to use this method the following preconditions have to be fulfilled: • The PEM installation has succeeded • The PEM configuration of the network has been done • The servers in the network are running • All regis[...]

  • Page 18

    Reference List 14 1/1531-HSD 101 41 Uen A 2004-01-30 Reference List System Overview, 1/1551-HSC 901 26/4, Ericsson AB 2004 PEM User’s Guide, 1553-AOM 901 018/3, Ericsson AB 2004 EDN312 User’s Guide,1/1553-HSD 101 41, Ericsson AB 2004 Subrack Installation Guide, 1/1531-HSC 901 026/4, Ericsson AB 2004 Outdoor Cabinet Installation Guide, 1531-1/BF[...]

  • Page 19

    [...]

  • Page 20

    Ericsson AB  Ericsson AB - 2004 All Rights Reserved www.ericsson.com 1/1531-HSD 101 41 Uen A 20 04-01-30[...]