Ericsson SOLUTION DESCRIPTION EDA 1200 4.0 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ericsson SOLUTION DESCRIPTION EDA 1200 4.0, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ericsson SOLUTION DESCRIPTION EDA 1200 4.0 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ericsson SOLUTION DESCRIPTION EDA 1200 4.0. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ericsson SOLUTION DESCRIPTION EDA 1200 4.0 should contain:
- informations concerning technical data of Ericsson SOLUTION DESCRIPTION EDA 1200 4.0
- name of the manufacturer and a year of construction of the Ericsson SOLUTION DESCRIPTION EDA 1200 4.0 item
- rules of operation, control and maintenance of the Ericsson SOLUTION DESCRIPTION EDA 1200 4.0 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ericsson SOLUTION DESCRIPTION EDA 1200 4.0 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ericsson SOLUTION DESCRIPTION EDA 1200 4.0, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ericsson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ericsson SOLUTION DESCRIPTION EDA 1200 4.0.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ericsson SOLUTION DESCRIPTION EDA 1200 4.0 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TA SOLUTION DESCRIPTION EDA 1200 4.0[...]

  • Page 2

    2 Introduction Broadband access is known to be the fastest growing technology in th e telecommunicati ons history. With the EDA broadband access concept, Ericsson has for several years demonstrate d technology leadership on the broadband market — Fi rst, by introducing the world’s first Ethernet-based IP DSLAM, then by constantly adding new and[...]

  • Page 3

    3 EDA 1200 overview The EDA 1200 solution (previously ca lled EDA Box) deploys an access network with switched Ethernet and a number of access drop technologies. Th e following sections describe the compon ents of the EDA 12 00 solution with emphasis on the cornerston e of the system - the IP DSLAM. EDA components The EDA solution comprises a numbe[...]

  • Page 4

    4 Solutions with IP DSLAM EDN612 The 12-line IP DSLAM EDN612 is the cornerstone of the new EDA 1200 product line specia lized for VDSL2 rollout with a fallback option for ADSL/ADSL2/ADSL2+. EDN612 is supported by the 12-port Gigabit aggregation switch ESN212; a nd together they form an unmatched scalability and deployment opportuni ty. This new gen[...]

  • Page 5

    5 Solutions with IP DSLAM EDN312 The 12-line IP DSLAM EDN312x is the c ornerstone of the existing EDA 1200 product line (the “blue Box”) and it provides full support for ADSL, ADSL2 and ADSL2+. The 12-line IP DSLAM EDN312x aggre gates all the incoming ADSL links onto one or two 100Base -T Ethernet connections depe nding of the bandwidth demand.[...]

  • Page 6

    6 Solutions for fiber and Cat5 EFN324 is the cornerstone of Er icsson's fiber access portfolio, targeting residential end-users, small offices/home offices (SOH O), and small to mediu m enterprises (SME). EFN324 is a multi-functio nal, optical fiber access node that supports triple play services, including multi cast video streaming with IGMP [...]

  • Page 7

    7 The most significant featu re is the integrated EDA Management Proxy (EMP) functiona lity. EMP enables the Ethernet Controller N ode to reduce management of IP addresses to just on e management IP address per Ethernet Controller Node, indepe ndent of the number of subtended IP DSLAMs. Ethernet Controller Node ECN33 0 is a natural aggregation poin[...]

  • Page 8

    8 ESN108 is especia lly designed for EDA 1200 series for deployment in areas wi th low subscriber pen etration. The switch ESN108 has a built-in PoE for powering of the IP DSLAM. In conn ect ion with the IP DSLAM EDN312x, ESN108 makes it possible to build small remote sites of up to 96 end-users with 1 Gbps uplink. ESN108 can be installed directly [...]

  • Page 9

    9 In this way, there is only one management i nterface and one static IP address. For provisioning, the EMP is managed via standard MIBs, and for system maintenance via EDA SNMP MIBs. All SW images an d configurations are stored i n local non-volatile memory to secure full operati on, even if access to th e management system is unavailable. EMP sec[...]

  • Page 10

    10 Traffic mapping End-user traffic is mapp ed to service VLANs. These VLANs may be end-user specific or common to multiple end-users. Through such VL ANs a single or multiple application services, e.g. voice, video or dat a, may be accessible. The traffic mapping to serv ice VLAN may be based on: • PVC or PVC bundle • VLAN • Line • Etherty[...]

  • Page 11

    11 ATM-based QoS The ATM-based QoS takes advan tage of the fine- grained segmentation into ATM cells, further minimizing latency and jitter. This ATM-based QoS can be combined with packet-based QoS. In the traditional setup, ther e is a fixed r elation between PVCs and VLANs for traff ic separation. The VLAN s are differentiated by priority and the[...]

  • Page 12

    12 Multicasting EDA supports the increasing demand f or streaming and high quality broadcast vid eo services by offerin g multicast for video streams b oth in the IP D SLAM (using IGMP Snooping) and in the aggregation layer. With Internet Group Mana gement Protocol (IGMP) multicast, parallel transmission of the same video stream is avoided. Snoopin[...]

  • Page 13

    13 The following VL ANs are depicted in the figure below, as an example of using VLANs per s ervice: • Voice VLAN for voi ce ToIP service • Video VLAN for video broadcast • Data VLAN for Intern et access service • Management VLAN used for all O&M Access methods Access methods are used to define rules suitable for specific end-user h ost[...]

  • Page 14

    14 DSL deployment and maintenance EDA supports VDSL2 ITU 993.2, ADSL2+ ITU G.992.5, ADSL2 ITU G.992.3 and ADSL ITU G.992.1. VDSL2 opens for up to 100/50 Mbps downstream/upstream bandwidth that enables the possibility for bandwidth demanding services in the ne twork. ADSL2+ also offers high bandwidth of up to 24 Mbps downstream. Single Ended Line Te[...]

  • Page 15

    15 It is, of course, also possibl e to use flexibl e topologies when adding VDSL2 to an already existing site with ECN330. With EDA 1200 ther e is always an efficient upgrade path at hand when introducing new technologies and solution s. Transport Ethernet over SDH Operators with an Ethernet-based core n etwork might still have an existing Sonet/SD[...]

  • Page 16

    16 Mechanical enclosures The EDA solution offers a n umber of mechani cal enclosures for easy an d trouble-free install ation. The enclosures are available in Eur opean and US variants. The US variants inclu de Telco connectors and NEBS approved protection for the ED N312x. The following en closures are a vailable: • Subrack for up to 36 ADSL sub[...]

  • Page 17

    17 288-line subrack The 288-line subrac k is equipped with 24 12-line IP DSLAMs (EDN312x); the height is 11 HU covering up to 288 lines. The subrack include s the 24-port Ethernet Controller Node ECN330. 288-line subrack 1152-line cabinet solutio n This solution consists of an Ericsson BYB501 cabinet. Housing up to four 288-line EDN288x IP DSLAMs, [...]

  • Page 18

    18 Outdoor cabinet wi th up to 96 subscribers EDA RSC96m The environmental cont rolled cabinet offers a compl ete solution for remote outdoor installatio n of EDA 1200: • 12 to 96 line VDSL2/ADSL2+ based on EDN612, ESN212 and optional EPN2 10 The EDA RSC96m solution can use direct air coolin g in the cabinet instead of the mo re traditional heat [...]

  • Page 19

    19 Outdoor cabinet wi th up to 24 subscriber EDA RSC96c The EDA RSC96c is specifical ly designed to h ouse temperature hardened ED A 1200 equipment. It uses direct air cooling in the cabinet instead of m ore traditional heat exch anger unit. Thi s means lower environmental load reg arding noise emission and powe r consumption. The cabinet can be u [...]

  • Page 20

    20 Technical specifications SUPPORTED STANDARD S xDSL standards : • ITU-T G.992.1 Annex A (ADSL over POTS) • ITU-T G.992.1 Annex B (ADSL over ISDN) • ITU-T G.992.3 Annex A (ADSL2 over PO TS) • ITU-T G.992.3 Annex B (ADSL2 over ISD N) • ITU-T G.992.3 Annex L (ADSL2 Reach Extended) • ITU-T G.992.3 Annex M (ADSL2 Symmetrical AD SL) • ITU[...]

  • Page 21

    21 IP DSLAM EDN288X WITH EXTRA ECN330 • Additional ECN330 c onfigured as switch on top of EDN288x • Fully assembled unit housed in 12 HU chassis • 2 x 10/100/1000 electrical or 2 x 100/1000 Mbps optical SFP uplinks and one additional elect rical 10/100/1000 Mbps uplink for each ECN330-switch • Power consumption (288 lines; tw o ECN330): Cab[...]

  • Page 22

    22 Ericsson AB www.ericsson.com 221 05-FAV 901 101/1 Uen C © Ericsson AB, Aug ust 2007[...]