Essick Air ADA71 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Essick Air ADA71, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Essick Air ADA71 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Essick Air ADA71. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Essick Air ADA71 should contain:
- informations concerning technical data of Essick Air ADA71
- name of the manufacturer and a year of construction of the Essick Air ADA71 item
- rules of operation, control and maintenance of the Essick Air ADA71 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Essick Air ADA71 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Essick Air ADA71, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Essick Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Essick Air ADA71.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Essick Air ADA71 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Circle the model of your cooler and record the serial number below . Read Carefully All Of This Manual Before Installing The Unit Encierrre con un circulo el modelo de su enfriador y escribe el número de série abajo. Lea Con Cuidado T odo Este Manual Antes De Instalar La Unidad Serial # Número De Série Safety Rules 1. Read instructions carefull[...]

  • Page 2

    2 1 10498-2 Electrical Installation W ARNING: Disconnect all electrical service that will be used for this unit befor e you begin the installation. • Remove junction box. The elec- trical junction box is located in the upper inside of the left center post. Remove the two screws and pull box out from panel for access to plug wiring (Fig. 4). • H[...]

  • Page 3

    3 1 10498-2 will protect you from someone turning on unit while you are working inside. This should be done for your safety . Adjust pulley to a larger diameter and readjust belt tension, plug motor in, install inspection panels, and retest amperage draw . Repeat this process until correct amperage draw is attained. Increasing motor pulley diameter[...]

  • Page 4

    4 1 10498-2 • Check belt tension. A 3 lb. force should de fl ect the belt 3/4 inches (see Fig. 1 1). Readjust belt if needed. • Oil bearings. The blower bearings and cooler motor in this unit should be oiled with a few drops of non-detergent 20/30 weight oil once each year . The motor does not need oil if it has no oil lines for oiling. Motors[...]

  • Page 5

    5 1 10498-2 Limited W arranty This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover damages in- curred through accident, neglect, or abuse by the owner . W e do not authorize any person or representative to assume for us any other or different liability in connecti[...]

  • Page 6

    6 1 10498-2 No. N° Description / Descripción ADA35 ASA35 1. T op, Blower Section / T apa De La Sección De La Rueda ...........................................................................222130-028 222130-028 2. T op, W et Section / T apa De la Sección De Agua ..................................................................................[...]

  • Page 7

    7 1 10498-2 Parts Drawing / Dibujo De Piezas ADA35, ASA35[...]

  • Page 8

    8 1 10498-2 No. N° Description / Descripción ADA51 ADA51 12 ADA71 ADA71 12 1. T op, Cabinet / T apa De La Caja ......................................................................... 222130-070 222130-070 222140-053 222140-053 2. T op Access Panel / Panel Superior De Acceso .................................................... 222130-074 222130-[...]

  • Page 9

    9 1 10498-2 Parts Drawing / Dibujo De Piezas ADA51 / ADA51 12 ADA71 / ADA71 12[...]

  • Page 10

    10 1 10498-2 No. N° Description / Descripción ASA51 ASA51 12 ASA71 ASA71 12 1. T op, Cabinet / T apa De La Caja .....................................................................222130-070 222130-070 222140-053 222140-053 2. T op Access Panel / Panel Superior De Acceso ................................................222130-074 222130-075 22213[...]

  • Page 11

    11 1 10498-2 Parts Drawing / Dibujo De Piezas ASA51 / ASA51 12 ASA71 / ASA71 12[...]

  • Page 12

    12 1 10498-2 No. N° Description / Descripción AUA51 AUA51 12 AUA71 AUA71 12 1. T op, Cabinet / T apa De La Caja ......................................................................... 322130-071 322130-071 322140-054 322140-054 2. T op Access Panel / Panel Superior De Acceso .................................................... 222130-074 222130[...]

  • Page 13

    13 1 10498-2 Parts Drawing / Dibujo De Piezas AUA51, AUA51 12, AUA71, AUA71 12 Lea Y Conserve Estas Instrucciones Reglas De Seguridad 1. Lea las instrucciones con cuidado. 2. Las conexiones eléctricas deben ser hechas por un electricista com- petente, para que todo el cableado eléctrico cumpla con los requisitos establecidos en su localidad. 3. S[...]

  • Page 14

    14 1 10498-2 • Quite la caja de empalme. La caja de empalme se encuentra en el poste izquierdo central en la parte superior del interior del enfriador . Quite los dos tornillos de la caja y aparte la caja del panel para tener acceso al cableado (véase fi g. 4). • Conecte el cableado eléctrico. Las conexiones eléctricas deben ser hechas por [...]

  • Page 15

    15 1 10498-2 Puesta En Marcha En La Primavera • Limpie el medio evaporativo. Un fi ltro limpio es más absorbente y e fi - ciente y producirá un mayor volumen de aire frío. Cada año o cuando sea necesario, limpie con una manguera de jardín las aberturas. Luego limpie el lado de adentro de cualquier escama u otra obstrucción a las aberturas[...]

  • Page 16

    16 1 10498-2 Preparar La Unidad Para El Invierno • Drene el agua. Drene siempre toda el agua de la unidad y del tubo de abas- tecimiento de agua cuando no use el enfriador durante períodos prolongados, especialmente al fi n de la temporada. El tubo debe quedarse desconectado del enfriador y del abastecimiento de agua para que no lo congele. •[...]