Go to page of
Similar user manuals
-
Humidifier
Essick Air 696 400
45 pages 1.09 mb -
Humidifier
Essick Air ED11 800
24 pages 1.96 mb -
Humidifier
Essick Air ECR 5200
16 pages 0.82 mb -
Humidifier
Essick Air 526 300
10 pages 0.17 mb -
Humidifier
Essick Air 447 401
15 pages 0.38 mb -
Humidifier
Essick Air 496 800
15 pages 0.38 mb -
Humidifier
Essick Air 726 series
10 pages 0.28 mb -
Humidifier
Essick Air 526 302
10 pages 0.17 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Essick Air ECR 4500, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Essick Air ECR 4500 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Essick Air ECR 4500. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Essick Air ECR 4500 should contain:
- informations concerning technical data of Essick Air ECR 4500
- name of the manufacturer and a year of construction of the Essick Air ECR 4500 item
- rules of operation, control and maintenance of the Essick Air ECR 4500 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Essick Air ECR 4500 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Essick Air ECR 4500, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Essick Air service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Essick Air ECR 4500.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Essick Air ECR 4500 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
ESSICK AIR PRODUCTS LITTLE ROCK, ARKANSAS 72209 50209-3 O WNERS MANU AL MODEL NO . ECR 3301 ECR 4000 ECR 4500 ECR 5200 ECR 6600 ECR 7200 CA UTION: Read All Instructions Carefully Bef ore Star ting The Installation. ESSICK CONVER TIBLE DO WN/FR ONT OUTLET EV APORA TIVE AIR COOLER[...]
-
Page 2
2 INST ALLA TION T ools and Supplies Y ou Need ......................................... 3 Saf ety Rules ................................................................... 3 Data ................................................................................ 3 Locating Y our Cooler ...................................................... 4 Conv er [...]
-
Page 3
3 T OOLS AND SUPPLIES Y OU WILL NEED • Pliers • Screwdriv ers • Adjustable Wrenches • T ubing Cutter • 5 / 32 He x Ke y Wrench • Electric Dr ill • Drill Bits • Hammer • Duct Caulking • #10 Sheet Metal Screws • Wiring Supplies, as Required by Local Electrical Code •L e v e l • Duct. As Required (a local sheetmetal shop can [...]
-
Page 4
4 LOCA TING Y OUR COOLER This new design Essic k cooler may be installed as a bot- tom or side air outlet cooler . The cooler must be securely f astened to a frame or pad mount. A roof kit is av ailable from Essick. A duct must be attached to the cooler outlet. The duct must be the same size as the cooler outlet. Sudden duct size changes will decre[...]
-
Page 5
5 1. Remove both louv ers and set them where they will not fall. See pg. 11. 2. Remove f our louver clips on side opposite motor . 3. Remov e a reser voir b y pushing the water crossov er tube from the grommet and lifting out the reservoir . 4. Remov e the second reser voir as abov e. 5. Remove the scre w that holds the wir ing box. 6. Remov e 1 / [...]
-
Page 6
6 INST ALLA TION Lift at cabinet cor ners. The cooler may be lifted by putting a bar or strap through the panel hole and lifting by means of the bar or strap . LIFTING COOLER CA UTION: DO NO T LIFT ON THE LOUVERS. REMO VE THE LOUVERS BEFORE LIFTING. DO NO T LIFT ON THE CENTER OF THE CABINET FLANGES. MOUNTING COOLER 1. Prepare duct to fit model used[...]
-
Page 7
7 INST ALLA TION ELECTRICAL CONNECTIONS The wiring must comply with local codes. If you are not f amiliar with the codes or wiring practices, get prof essional help. Use only an Essick ECR-5 or ECR-7 w all mounted switch. This new cooler does not require pre wetting the pads bef ore star ting cooling and does not hav e a pump . Existing switches wi[...]
-
Page 8
8 INST ALLA TION FINAL ASSEMBL Y AND ADJUSTMENT PUT FLO A T V AL VE IN COOLER Put the float valv e through the spout hole and cabinet hole. Tighten the ring nut. Be sure the float mov es straight up and do wn. TURN THE FLO A T UNTIL A NARRO W SIDE IS UP . Snap the Splash Guard Cov er into the W ater Spout as shown. The W a ter Spout and Splash Guar[...]
-
Page 9
9 IMPOR T ANT NO TE: When checking amperage with the ampmeter , all louv ers must be in place in the cooler , otherwise incorrect setting of the drive pulle y will occur . MO T OR PULLEY ADJUSTMENT NO TE: ALL DUCT CONNECTED COOLERS MUST BE ADJUSTED . Long or small air ducts hav e e xcessive air resistance which decreases air output and motor ampera[...]
-
Page 10
10 HO W Y OUR COOLER WORKS Y our cooler evaporates water to cool air . Evaporative air cooling is the same natural cooling that happens when a breeze springs up after a summer shower . Y ou f eel cool because the rain water e vaporates and carries aw ay heat. Y our new cooler has a motor (1) driv en blower (2) which dra ws outside air through pads [...]
-
Page 11
11 CARE OF Y OUR COOLER NEVER WEAR SHOES WITH SLICK SOLES WHEN Y OU W ORK ON A ROOF . Y OU MA Y SLIP WHEN Y OU LEAST EXPECT IT . NEVER DRAIN W A TER ONTO A R OOF . W A TER RESIDUE MA Y CA USE Y OU T O SLIP OR MA Y ST AIN Y OUR ROOF . USE A DRAIN HOSE T O R UN W A TER TO A RAIN GUTTER OR T O THE GROUND . F ALL CARE: Drain the cooler and water line t[...]
-
Page 12
12 Operation of Roto Belt Coolers in “Hardwater” Areas. 1. Clean the cooler frequently . 2. Remov e mineral buildup from water troughs and Roto Belt to prev ent clogging. 3. A water analysis will determine: mineral content, what water treatments can be used, what cleaning agents should be used. 4. A “ bleed-off ” kit (Stock No . 8C190) shou[...]
-
Page 13
13 REPLA CEMENT P ADS MODEL NUMBER P AD NUMBER ECR 3301 EP-30 ECR 4000 EP-40 ECR 4500 EP-40 ECR 5200 EP-50 ECR 6600 EP-60 PUTTING ON NEW P AD (Fig. 20) THE P ADS NEED NO PREWETTING. 1. Put the lower roller in pad. 2. Fit the low er roller into the bottom slots in the frame. 3. Push the top roller through the pad. Fit the roll end ov er the pad moto[...]
-
Page 14
14 ESSICK CONVERTIBLE DO WN/FRONT OUTLET EV APORA TIVE AIR COOLER MODEL NOS. ECR 3301, ECR 4000, ECR 4500, ECR 5200, ECR 6600, ECR 7200 REP AIR P ARTS[...]
-
Page 15
15 ESSICK CONVERTIBLE DO WN/FRONT OUTLET EV APORA TIVE AIR COOLER MODEL NOS. ECR 3301, ECR 4000, ECR 4500, ECR 5200, ECR 6600, ECR 7200 NO TICE: Order by P AR T NUMBER, not by K ey Number . Refer to the bac k cover of this man ual for par ts ordering information. KEY P ART NUMBER NO. ECR 3301 ECR 4000/4500 ECR 5200 ECR 6600/7200 P ART NAME 1 30439 [...]
-
Page 16
ESSICK AIR PRODUCTS 5800 MURR Y • LITTLE ROCK, ARKANSAS 72209 501-562-1094 owners manual MODEL NO . ECR 3301 ECR 4000 ECR 4500 ECR 5200 ECR 6600 ECR 7200 HO W T O ORDER REP AIR P ARTS ESSICK CONVER TIBLE DO WN/FR ONT OUTLET EV APORA TIVE AIR COOLER The model number of y our cooler will be found on a label fastened to the housing. WHEN ORDERING RE[...]