A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ETA Systems ETA-ECS6RM, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ETA Systems ETA-ECS6RM one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ETA Systems ETA-ECS6RM. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ETA Systems ETA-ECS6RM should contain:
- informations concerning technical data of ETA Systems ETA-ECS6RM
- name of the manufacturer and a year of construction of the ETA Systems ETA-ECS6RM item
- rules of operation, control and maintenance of the ETA Systems ETA-ECS6RM item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ETA Systems ETA-ECS6RM alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ETA Systems ETA-ECS6RM, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ETA Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ETA Systems ETA-ECS6RM.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ETA Systems ETA-ECS6RM item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    – 1 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 ET A-ECS6RM Electrical Control Sequencer ET A-ECS6RM Electrical Control Sequencer[...]

  • Page 2

    – 2 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 T ABLE OF CONTENTS Safety .....................................................................................................................................................[...]

  • Page 3

    – 3 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this device near water . 6. Clean o[...]

  • Page 4

    – 4 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 CAUTION– WHEN INST ALLING THE PRODUCT  •  Pluggingin orunplugging thepower cordwith wet handsmay resultin electricsho[...]

  • Page 5

    – 5 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 INTRODUCTION Thank you for purchasing the ET A Systems ET A-ECS6RM Intelligent AC Power Sequencer . The ET A-ECS6RM (Electrical Controller Sequencer with Six T iming Sections [...]

  • Page 6

    – 6 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 ET A-ECS6RM KEY FEA TURES  • 6Sequencer T iming Sections,1,3, or6 SecondIntervals  • 6Independent ECMConnections  • 6?[...]

  • Page 7

    – 7 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 FRONT P ANEL 1. System Activation Switch – T o activate or deactivate the system sequence, press the momentary switch once. There must be at least one ECM (Electrical Contro[...]

  • Page 8

    – 8 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 4. Channel Selection Switches – These push button switches allow the selection of the channel to be viewed at the V oltage and Current Meter . 5. Channel Selected LEDs – T[...]

  • Page 9

    – 9 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 REAR P ANEL 1. ECM Control Ports – Up to 6 AC Main circuits can be activated or monitored by the ET A-ECS6RM. Each ECM control port connects to one of the following ECM modu[...]

  • Page 10

    – 10 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 4. T rigger Switches – Up to three ET A-ECS6RM units can be daisy chained together giving you 18 sequenced outputs. T o do so you need to set the timing sequence of each un[...]

  • Page 11

    – 11 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 ECM DA T A WIRE AND DIST ANCE There are four different types of ECM Modules that require the same interface connectivity to the ET A-ECS6RM. All ECM Modules can be interfaced[...]

  • Page 12

    – 12 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 ECM INDICA TOR AND P ART DESCRIPTION 1. T rigger / Status Port Pin Identification – all signals are of low voltage and current. DO NOT MISWIRE or damage may occur . + Requi[...]

  • Page 13

    – 13 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 ET A-ECS6RM ACCESSORY ITEMS AP-GNL18 – LED Gooseneck LAMP The Atlas Power AP-GNL18 is an optional LED Gooseneck Lamp and works with any of the ET A Systems 12VDC XLR base m[...]

  • Page 14

    – 14 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 ECM-RACEWY6 ECM Housing The ET A-ECM20 and ET A-ECM20M require an electrical housing. The ECM-RACEWY6 holds up to 6 ECM modules. There are standard ¾" and 1" elect[...]

  • Page 15

    – 15 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 ET A-ECM20 20A AC Control Module (No Current Monitoring) The ET A-ECM20 does not support the same Current monitoring or EMI/RFI Filter feature as the ET A-ECM20M, ET A-20SH a[...]

  • Page 16

    – 16 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 ET A-ECS6RM WIRING CONFIGURA TION Example 1 – ET A-ECS6RM wired to six ET A-ECM20 or ET A-ECM20M Modules using an ECS-KSW6 for remote activation. Example 2 – ET A-ECS6RM [...]

  • Page 17

    – 17 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 Example 3 – Three ET A-ECS6RM wired to 18 ET A-ECM20 or ET A-ECM20M Modules. Example 4 – ET A-ECS6RM wired to 4 ET A-ECM20 or ET A-ECM20M Modules that are in the ECM-RACE[...]

  • Page 18

    – 18 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 EXAMPLES ET A-ECM20/M20RW MODULE WIRING CONFIGURA TIONS The ET A-ECM20/M20RW is designed to be mated with the ECM-RACEWY6 housing and the ET A-ECS6RM controller . The specifi[...]

  • Page 19

    – 19 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 TROUBLESHOOTING Note: All troubleshooting should be done by a certified electrician. Issue 1 – ECM Module Incoming AC LED is not illuminated. Possible Cause #1 Incoming AC [...]

  • Page 20

    – 20 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 Issue 5 – ET A-ECS6RM Channel Activation Status LED is Flashing Green and AC Power and Active LED at the ECM Module is Illuminated. Possible Cause The AC Mains V oltage at [...]

  • Page 21

    – 21 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 ET A-ECS6RM SPECIFICA TIONS General T ype Power Sequencer Controller Sequencer Sections 6 Relay Sections 6 Sequence T iming Unit Settings of 1, 3 or 6 Seconds Unit Link 3 Pow[...]

  • Page 22

    – 22 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 NOTES ET A-ECS6RM Electrical Control Sequencer[...]

  • Page 23

    – 23 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 NOTES ET A-ECS6RM Electrical Control Sequencer[...]

  • Page 24

    – 24 – ET Asys.com Specifications are subject to change without notice. 1601 Jack McKay Blvd. • Ennis, T exas 75119 U.S.A. T elephone: 800-321-6699 • Fax: 800-996-3821 LIMITED W ARRANTY All products manufactured by ET A Systems are warranted to the original dealer/installer , industrial or commercial purchaser to be free from defects in mat[...]