Go to page of
Similar user manuals
-
DVR
EverFocus ECOR264-4F1
2 pages 0.55 mb -
DVR
EverFocus EDR HD-4H4
2 pages 0.14 mb -
DVR
EverFocus ECOR264-4D1
128 pages 4.26 mb -
DVR
EverFocus EDSR 400F
112 pages 5.9 mb -
DVR
EverFocus 16D3
6 pages 1.85 mb -
DVR
EverFocus ECOR264-16X1
147 pages 4.86 mb -
DVR
EverFocus EDR920
77 pages 1.14 mb -
DVR
EverFocus TRUE
2 pages 0.55 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of EverFocus EDSR-600, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of EverFocus EDSR-600 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of EverFocus EDSR-600. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of EverFocus EDSR-600 should contain:
- informations concerning technical data of EverFocus EDSR-600
- name of the manufacturer and a year of construction of the EverFocus EDSR-600 item
- rules of operation, control and maintenance of the EverFocus EDSR-600 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of EverFocus EDSR-600 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of EverFocus EDSR-600, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the EverFocus service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of EverFocus EDSR-600.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the EverFocus EDSR-600 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INSTRUCTION MANUAL V1.05 2004/3/25 EDSR - 400 4 Channel Duplex Digital Video Recorder EDSR - 600 6 Channel Duplex Digital Video Recorder[...]
-
Page 2
? Refer all work related to the installation of this product to qu alified service personnel or system installers. ? Do not block the ventilation opening or slots on the cover. ? Do not drop metallic parts through slots.This could permanently damage the appliance. Turn the power off immediately and contact q ualified service personnel for service. [...]
-
Page 3
The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance(servicing)instructions in the literature accompanying the appliance. Safety Precautions Warning : To prevent fire or shock hazard, do not expose units not specifically designed for outdoor use to rain or moisture. Th[...]
-
Page 4
Important Safeguards Read Instruction --- All the safety and operating instructions should be read before the init is operated Retain Instructions --- The safety and operating instructions should be retained for fut ure reference. Heed Warnings — All warnings on the unit and in the operating instructions shoul d be adhered to. Follow Instructions[...]
-
Page 5
Table of Contents 1. Product Overview …………………………………… . ……………… .. … .. … ..Page 1 1.1 Main features ………………………………………………………………… ..... … .. … .1 1.2 Specifications ……………………………………………………………… .. ………… ..2[...]
-
Page 6
1. Product Overview The EDSR400/EDSR600 Duplex Digital Video Recorder (DVR) a full - featured DVR designed specifically for use in security industry. The DVR incorporates all the benefits of digital video recording , is simple to install, and operates just like a VCR. Highly efficient compression technology and superior resolution of recorded image[...]
-
Page 7
Specifications 2 1.2 Specifications 4 ( EDSR400) / 6 (EDSR600) camera inputs (BNC),1Vp - p/75ohm 430 mm (W) x 88mm (H) x 300 (D) Dimension AC100~240V Power Source 100 W max. Power Consumption Video Input M - JPEG Video Compression 0 ° C ~ 40 ° C; 20~80% Operating Temperature 2 x RJ45 Socket RS485 9 - pin female D - Sub RS - 232 Yes Watch Dog Time[...]
-
Page 8
Back Panel Connections 2. Back Panel Connections 1 ON/OFF: Main on/off switch. 2 AC100~240V power socket . 3 VIDEO IN: BNC - sockets for composite signal video inputs, automatic 75 Ohm termination. (EDSR400:1~4, EDSR600: 1~6) 4 VIDEO OUT: Loop through video outputs for each input channel. (EDSR400:1~4, EDSR600: 1~6) 5 6 CALL MONITOR: BNC - socket C[...]
-
Page 9
4 10 ALM - OUTPUT : Two - way contact relay alarm output. In normal condition, this N.C. c ontact shorted to ALM - COM. In alarm status, it is open between ALM - NC and ALM - COM, N.O. is shorted to ALM - COM. ALM - INPUT : Normally Open (N.O) or Normally Close (N.C) type alarm sensor in put. The Alarm Input can be selected as N.O or N.C input in t[...]
-
Page 10
System Connection 5 3. System Connection The installations described below should be made by qualified se rvice personnel or system installers. Before Installation Please refer to the following diagram for the system connections . EDSR 400: Camera 1~4 / EDSR - 600: Camera 1 ~ 6 CALL Monitor Audio Input (camera Audio Out) Audio Out (To Speaker) MAIN[...]
-
Page 11
Front Panel Keypads 4. Front Panel Keypads SHUTTLE : In Playback mode, turn the shuttle ring to fast forward/rewind the picture (600X maximum). In Pause mode, turn the shuttle dial to slo w forward/rewind the picture (1/32 maximum). JOG : In Pause mode, turn the jog dial to step forward/rewind the Pict ure. In Menu mode turn the jog dial to select [...]
-
Page 12
LEDs: LEDs for HDD1, HDD2 , ALARM and LAN access (from left to right) . IR Remote Controller receiver 7 Display: Press this key to switch ON/OFF for camera title, date/time and HDD status. Hold this key longer than 2 seconds for displaying the event log list. 9 10 Compact Flash Card Slot: Insert a Compact Flash Card for archiving video. Hard Disk T[...]
-
Page 13
Operation 8 (1) Insert a HDD (IDE) for Video Storage (2) Connect cable for video/audio input and video/audio out, The detail connection is described in SYSTEM CONNECTION . (3) Switch Power On (4) Press MENU key to enter SET UP MENU. Once inside the main menu you will find there are 14 set up page s as below: Selected item will be surrounded by a wh[...]
-
Page 14
MENU flow 6. MENU FLOW CLOCK ( See page 11 ) : 2004/2/27 FRI : 13:01:02 CLOCK SETTING MENU DATE TIME MENU LANGUAGE: ENGLISH VIDEO SYSTEM: NTSC VERSION: 1.05 TIMER SETTING MENU WEEK START STOP SPEED SET SUN 00:00 23:59 60 IPS OFF SUN 00:00 23:59 60 IPS OFF SUN 00:00 23:59 60 IPS OFF SUN 00:00 23:59 60 IPS OFF SUN 00:00 23:59 60 IPS OFF SUN 00:00 23:[...]
-
Page 15
BUZZER ( See page 22 ) BUZZER SETTING MENU BUZZER : ENABLE RECORD - IN : ON ALARM - IN : ON MOTION - IN : ON DISK FULL : ON VIDEO LOSS: ON TIMER : ON ARCHIVE ( See page 23 ) PICTURE SIZE TIME STAMP TIME STAMP POS WATER MARK WATER MARK POS ARCHIVE SETTING MENU : 720 X 480 : ON : TOP : ON : TOP CALL ( See page 24 ) CH DWELL EVENT 1 07 SECS NONE 2 07 [...]
-
Page 16
MENU 11 In CLOCK/LANGUAGE SETTING MENU , we define: (1) DATE : Current date, format: YYYY/MM/DD Year: 2000 ~ 2099, Month: 01~ 12, Date: 01~31, Week: Sunday~Saturday (2) TIME : Current time, format: HH:MM:SS Hour: 00 ~ 23, Minute : 00 ~ 59, Second: 00 ~ 59 (3) MENU LANGUAGE: ENGLISH or Others (4) VIDEO SYSTEM : Factory default setting depend on mach[...]
-
Page 17
MENU 6 .2 TIMER SETTING MENU 12 Timer records can be defined for 12 individual start and end tim es. (1) WEEK: This select the week day for the timer to record on schedule. DLY means daily record. (2) START: Enter the start time for timer recording. (3) STOP: Enter the end time for timer recording. NOTE: The recorder records till the end of the min[...]
-
Page 18
MENU (1) CH (Channel): Input channels 1~4 for EDSR400, 1~6 for EDSR600. (2) OP (Operation): ON includes the camera in the sequence, OFF skips the camera in the sequence. (3) DWELL (DWELL TIME) : Dwell Time is individual adjustable for each channel. The dwell ing time for the sequencer can be set between 0 - 99 seconds. 13 6 .3 SEQUENCE SETTING MENU[...]
-
Page 19
MENU 14 6 .4 TITLE SETTING MENU In TITLE SETTING MENU , we define: The Title Setting Menu allows you to assign a title to each came ra input. Title with up to 12 characters is supported in each channel. The available alphanumeric characters are: 0,1,2,3,4,5,6,7,8,9, A,B,C,D, … X,Y,Z. / ( ) . - * & @ : ” Default setting is CH01~CH04 for EDSR[...]
-
Page 20
6 .5 COVERT SETTING MENU COVERT SETTING MENU CH OP 1 OFF 2 OFF 3 OFF 4 OFF (5 OFF) (6 OFF) In COVERT SETTING MENU , we define: The covert setting menu allows you hide the desired camera on th e display in a blue background. Change setting to ON for covering camera. Camera is not visible in Live and Playback mode, unless this fun ction is deactivate[...]
-
Page 21
In ALARM RECORDING MENU, we define (1) CH (Alarm input) : Select alarm input or RST for alarm reset input. (2) OP (OPERATION) : ON : Records when alarm occurs. OFF : No reaction when alarm occurs. (3) TYPE : Select alarm type: N.C. : Normally Closed with time out function counting from alarm start (set in DURATION) N.C. + TRANS : Normal Closed, ala[...]
-
Page 22
MENU (1 ) CH (Channel) : Video input channel (2) OP (Operation) : Default: OFF ON: The device will respond recording when motion occurs. OFF: The device will not respond recording when motion occurs . (3) SEN (Sensitivity) : HIGH, MIDDLE or LOW adjustable. Default: MIDDLE. (4) DURATION: Duration time for motion record and Alarm Out relay. 0~99 seco[...]
-
Page 23
MENU ( 5) Press 1 - 4/6 TO MANUAL EDIT: Use the numeric keys (1~4 for EDSR - 400 / 1~6 for EDSR - 600) to select a camera for setting the detection areas. The selected camera appears with a 16 x 12 grid (detection zones ): Follow the Dialog for further operation. PRESS ENTER TO SELECT NODE USE JOG TO TOGGLE ON/OFF PRESS MENU TO EXIT 18 Turn the JOG[...]
-
Page 24
MENU 19 In NORMAL RECORDING MENU, we define (1) NORMAL RECORD: SPEED : To set the normal recording speed. Maximum 60 (NTSC) / 50 (PAL) . QUALITY: Video recording quality setup for setting the quality of the vi deo picture by selecting a compression rate. There are six quality levels for r ecording LOWER : 15 KB LOW : 19 KB BASIC : 23 KB STANDARD : [...]
-
Page 25
6 .9 NETWORK SETTING MENU IP ADDRESS NET MASK ADDRESS GATEWAY ADDRESS MAC ADDRESS USER - NAME PASSWORD LEVEL NETWORK SETTING MENU : 192 .168.010.005 : 255 .255.255.000 : 192 .168.010. 001 : 00:5 A:56:A3:87:1A GUEST --- GUEST --- GUEST --- GENERAL - GENERAL - GENERAL - ADMIN --- ADMIN --- ADMIN --- (1) IP ADDRESS : Assign an fixed IP address for thi[...]
-
Page 26
MENU (1) RS232 BAUD RATE: There are 6 different speeds that can be used to transmit inst ruction or information through the RS232 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud, 19200 baud,and 3840 baud. The default setting from the factory i s 9600 baud. (2) RS232 STOP BIT: Select stop bit: 1 or 2 (3) RS232 PARITY: Select parity mode:[...]
-
Page 27
In BUZZER SETTING MENU, we define the buzzer ON/OFF for following event: RECORD - IN, ALARM - IN, MOTION - IN, DISK FULL, VIDEO LOSS AND TIMER MENU 22 6 .11 BUZZER SETTING MENU BUZZER SETTING MENU BUZZER : ENABLE RECORD - IN : ON ALARM - IN : ON MOTION - IN : ON DISK FULL : ON VIDEO LOSS : ON TIMER : ON Turn the JOG dial clockwise or counter - cloc[...]
-
Page 28
MENU 6 .12 ARCHIVE SETTING MENU (1) PICTURE SIZE : Selects picture size for copying image to CF card: Big size:720x480 / 720x576 for NTSC / PAL. Small size:352x240 / 352x288 for NTSC / PAL. (2) TIME STAMP : ON : Shows the time stamp on the picture when copying image to CF c ard. OFF : This erases the time stamp on the picture when copying image t o[...]
-
Page 29
6 .13 CALL MONITOR SETTING MENU 24 CH DWELL EVENT 00 07 SECS NONE 00 07 SECS NONE 00 07 SECS NONE 00 07 SECS NONE (00 07 SECS NONE) (00 07 SECS NONE) CALL MONITOR SETTING MENU In the CALL MONITOR SETTING MENU, we define the sequences of each CH for call monitor . CH, DWELL, EVENT: (1) CH (Channel): Select the camera to be shown in the standard sequ[...]
-
Page 30
MENU 25 6 .14 DISK SETTING MENU (1) DISK USAGE: HDD - 1, HDD - 2 (2) SIZE: Applied HDD size. (3) RECORD POS: HDD usage rate, record position, “ * ” shows the active HDD (4) PLAY POS: current playback position, “ * ” shows the active HDD (5) DISK RENEW: Erase HDD - 1, HDD - 2 In the DISK SETTING MENU, we define DISK SETTING MENU DISK USAGE H[...]
-
Page 31
MENU 26 6 .15 SYSTEM SETTING MENU (1 ) PLAY WITH AUDIO: AUDIO - 1, AUDIO - 2 ON/OFF: Play back with or without audio. (2) PLAY SPEED: Set the playback speed. Maximum 60 (NTSC) / 50 (PAL). (3) PASSWORD ENABLE: Enable/Disable the password protection. Once you enable the password, the default value is Level - 1 (Lowest level) for live view only (CH ke[...]
-
Page 32
7 .1 INSTANT RECORDING Press REC key to start continuous recording with setting of “ NORMAL RECORD ” . The recording rate and recording quality are set in the RECORD S ETTING MENU. The LCD screen on the front panel of DVR will display as follows : Recording REC Press STOP key to stop recording. Since the DVR had Duplex feature, STOP key can be [...]
-
Page 33
8 .1 NORMAL PLAYBACK Press the PLAY key to start playing back the stored image/audio from the last SEGMENT. (1) Playback (2) Fast Forward/Reverse Playback During playing back, turn the SHUTTLE ring clockwise to start fast forward playing back. The speed will be shown on the screen at the bottom of the scree n. >> 2X, 4X, 8X, 16X, 32X, 600X Tu[...]
-
Page 34
8 .2 SEARCH PLAYBACK Press SEARCH key to enter the SEARCH MENU dialog. Search Playback SEARCH 29 SEGMENT SEARCH 0001 0002 0003 2003/04 /24 19/03 /29 HDD1 2003/04/25 12/30/30 HDD1 2003/05/20 12/00/00 HDD2 SEARCH MENU BY SEGMENT LIST BY ALARM LIST BY DATA TIME Turn the JOG dial to select BY SEGMENT LIST and press ENTER key. A segment is a range on th[...]
-
Page 35
(2) Alarm List search playback 30 A01 : Alarm recording by Alarm - in 1. M03: Motion recording by camera 3. T : Timer recording. PL: automatic record restart after end of power loss : The icon means there is more than one page list. Use “ SHTTLE ” to change between pages or use “ JOG ” to select one list. Press SEARCH key to enter the SEARC[...]
-
Page 36
(3) Date/Time Search Playback DATE/TIME SEARCH YEAR/MM/DD HH:MM:SS HDD 2003 /01 /01 21: 33: 26 1 PRESS SEARCH TO START SEARCH PRESS MENU TO EXIT 31 Notice: If there is no image stored in the date/time specified then the machine will start playing back from the nearest set time automatically. Press SEARCH key to enter the SEARCH MENU dialog. SEARCH [...]
-
Page 37
DATA EXPORT Insert a Compact Flash card into the Compact Flash slot on the f ront panel of DVR. When inserting the Compact Flash card, make sure that insert dir ection is correct. NOTE: COPY function is not possible during RECORD. Stop recording to enable COPY function! Turn the JOG Dial clockwise to choose your desired image. PAUSE The still image[...]
-
Page 38
COPY Press COPY key and then the copy menu and instruction appears. The main monitor switches to full screen display with following OSD: 33 Press the PLAY key to start playing back. PLAY 9 .2 COPY TO MOVIE FILE CH01 COPY TO MOVIE FILE USE JOG TO SELECT PICTURE PRESS COPY TO START COPY PRESS PAUSE TO PAUSE COPY PRESS STOP TO CLOSE FILE PRESS MENU TO[...]
-
Page 39
9 .3 EXPORT EVENT LOG LIST DATA EXPORT This function allows to export the event log list to CompactFlas h – Card. The generated text file is in *.txt format. DISPLAY Press „ DISPLAY “ key and hold key for about 2 seconds. EVENT LOG TYPE ID TIME MOTION 2 2004/01/02 12:12:54 VL 1 2004/01/02 12:12:54 VL 3 2003/12/29 12:12:54 VL 1 2003/12/28 12:1[...]
-
Page 40
MONITOR VIEWS / OPERATION 10. MONITOR VIEWS / OPERATION 10.1. MAIN MONITOR The EDSR400/EDSR600 digital recorders provide 1 main monitor and 1call monitors. These monitors have different functionalities: Main monitor: - Full screen and multi screen display EDSR400: F ull screen , 4, PIP, and 2x zoom EDSR600: F ull screen , 4, 6, PIP, and 2x zoom - L[...]
-
Page 41
Press CALL to change settings for CALL monitor. The Main monitor shows following dialogue: MONITOR VIEWS / OPERATION 10.2. CALL MONITORS 36 CALL SETTING CALL MONITOR... SPOT 03 OSD ON HIT 1~4 (1~6) TO SELECT SPOT CAMERA PRESS SEQ FOR SEQUENTIAL CAMERA PREE DISPLAY TO TURN OSD ON/OFF PRESS MENU TO EXIT Please follow the instruction on the display fo[...]
-
Page 42
RJ45 (RS485) pin assignment 11. REMOTE CONTROL 11.1 RS - 485 REMOTE CONTROL The new standard EverFocus EDSR remote protocol allows challengi ng installations with DVR remote control at different installation sites. EDSR remote control is supported by the optional keyboards KS - KBJ (with 3 - axis joystick and 2 additional RS - 485 – Ports for tel[...]
-
Page 43
IR Remote Controller The remote controller (RC - 200, Figure 1) is an accessory to enhance the handy operations o f the DVR. You can perform all the settings and operations by the rem ote controller. The effective distance is up to 10 meters without any obstacle. The keypad fun ctions are same as the front panel key button of the DVR. There are som[...]
-
Page 44
12. View From Internet/Intranet Basic Operations and Login Display: Go to the Internet Explorer, key in the network IP address, for example, http://192.168.10.5 (must be the same IP address as the one assigned to the unit from the Network Setting Menu. You need a FIXED IP Address, please contact your ISP for the IP) The LOGIN dialog will show on th[...]
-
Page 45
Main Screen Above diagram is the main screen display. The icons on the lower corner of the screen are mainly for contr ol and Configuration, those on the right corner are for status indication. If any icon is grayed, it means that the specific function is no t accessible in the current mode. The followings are a brief description for each of the ic[...]
-
Page 46
10. The system allows up to 3 ways playback video, by SEGMENT, ALARM LIST and DATE TIME . ( Playback by SEGMENT LIST, click Refresh to show list) ( Playback by Date time) 41 ( Playback by ALARM LIST, click Refresh to show list) View From Internet/Intranet Above pictures are sampling from EDSR900 9 CH DVR for reference.[...]
-
Page 47
11. All available segments are shown in the list. Click to select an d highlight. 12. Click to playback selected video segment. 13. Press this icon to show the segment or list. 14. Current connection and playback status is shown along with date and time. 15. Full screen view. 16. Quad screen view. 17. Nine split screen view. (only for 9 CH DVR). 18[...]
-
Page 48
Appendix - A LAN Functional Specification Specifications: Network Interface: 10Mbits/s Ethernet (10Base T) LAN controller Chip: RealTek 8019 LAN Connector: RJ - 45 Protocol: HTTP,TCP/IP.ICMP,ARP Remote Access: Standard browser such as inte rnet Explorer / Netsca pe with JAVA support Image Compression: JPEG Used Ports: 80, 1111, 2222, 3333, 4444, 66[...]
-
Page 49
Appendix - B ? When Recording with 160GB HDD 44 Lower Low Basic Standard High Superior : 15 kB : 19 kB : 23 kB : 27 kB : 31 kB : 35 kB ( Estimated with typical image - low noise level) Time Lapse Mode Recording Time Table Reference:24H=1 day.168H=1 week, 720H=1 month,8760H=1 year NTSC Unit: Hour system storage(GB): 160 Recording Speed LOWER LOW BAS[...]
-
Page 50
? When Recording with 320GB HDD Lower Low Basic Standard High Superior : 15 kB : 19 kB : 23 kB : 27 kB : 31 kB : 35 kB Appendix - B 45 ( Estimated with typical image - low noise level) Reference:24H=1 day.168H=1 week, 720H=1 month,8760H=1 year NTSC Unit: Hour system storage(GB): 320 Recording Speed LOWER LOW BASIC STANDARD HIGH SUPERIOR (fps) 15 19[...]
-
Page 51
Appendix C: Serial Interface Specifications 2. Transmission setting PIN # NAME PIN # NAME 1 NOT CONNECTED 1 NOT CONNECTED 2 TXD 2 RXD 3 RXD 3 TXD 4 NOT CONNECTED 4 NOT CONNECTED 5 GROUND 5 GROUND 6 NOT CONNECTED 6 NOT CONNECTED 7 NOT CONNECTED 7 NOT CONNECTED 8 NOT CONNECTED 8 NOT CONNECTED 9 NOT CONNECTED 9 NOT CONNECTED DVR HOST 1 5 3 9 2 8 4 7 6[...]
-
Page 52
3. Remote Control Protocol A computer or a terminal can be used to control the unit by send ing the packet as following. 47 1 - 1. Sample control code packets Example1 : A packet that send "REC" key to DVR (ID=5) 0x85 (length) 0x00 (Receiver ID high byte) 0x05 (Receiver ID low byte) 0x4B (OPcode = key ) 0x08 (DATA1 = "Rec " keyc[...]
-
Page 53
48 2 - 1. The format of message packet is as follows: Length Byte (Prefix: 0x86, 0x87, or 0 x88 ..... ) Receiver ID high byte Receiver ID low byte Opcode Byte Data Byte1 Data Byte2 Data Byte3 Checksum Byte 2 - 2. Length Byte This Length Byte is also a prefix. Bit7 must be 1. EX: 0x87 ==> this packets has 7 bytes length. ( not include d Length by[...]
-
Page 54
49 2 - 3. Receiver ID 2 - 3. Receiver ID 1). Individual receiver ID Decimal 14bit binary value Hbyte Lbyte Receiver ID (EDSR) 0 0000000 0000000 00 00 ID = 0 1 0000000 0000001 00 01 ID = 1 2 0000000 0000010 00 02 ID = 2 .... 126 0000000 1111110 00 7e ID = 126 127 0000000 1111111 00 7f ID = 127 128 0000001 0000000 01 00 ID = 128 129 0000001 0000001 0[...]
-
Page 55
50 2 - 4. Opcode Byte & Data bytes 2 - 4 - 1. OPcode OPcode Data1 Function 0x4B Keycode A remote key pressed 0x4D command Matrix command 2 - 4 - 2. Remote keys (OPcode =0x4B) ---------------------------------------------------------------- ------------------------------------ Data1 Key Data1 Key 0x00 CH1 0x01 CH2 0x02 CH3 0x03 CH4 0x04 MODE 0x0[...]
-
Page 56
Appendix - D 51 Alarm I/O pin assignment T he alarm connector, Figure 1 , is used to provide one sensor alarm input for each camera inpu t. For easy operation, an alarm extension board, Figure 2 , is provided to connect to the alarm connector. Each alarm input requires two wires, one wire connects to the de sired alarm input pin, the second wire co[...]
-
Page 57
EverFocus Electronics Corp. Head Office: 12F, No.79 Sec. 1 Shin - Tai Wu Road, Hsi - Chi, Taipei, Taiwan TEL: +886 - 2 - 26982334 FAX: +886 - 2 - 26982380 www.everfocus.com.tw USA Office: 2445 Huntington Drive, San Marino, CA 91108, U.S.A. TEL: +1 - 626 - 844 - 8888 FAX: +1 - 626 - 844 - 8838 www.everfocus.com Japan Office: 1809 WBG Maribu East 18F[...]