Go to page of
Similar user manuals
-
Switch
Extron electronic 100
2 pages 1.08 mb -
Switch
Extron electronic MLS 100 A
27 pages 1.85 mb -
Switch
Extron electronic ISS 108
104 pages 3.62 mb -
Switch
Extron electronic MLS 304MA
62 pages 3.04 mb -
Switch
Extron electronic RGB 103
17 pages 0.57 mb -
Switch
Extron electronic DTP DVI 230
19 pages 3.16 mb -
Switch
Extron electronic 1616
104 pages 4.67 mb -
Switch
Extron electronic DXP DVI
137 pages 9.52 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Extron electronic DMS 3600, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Extron electronic DMS 3600 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Extron electronic DMS 3600. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Extron electronic DMS 3600 should contain:
- informations concerning technical data of Extron electronic DMS 3600
- name of the manufacturer and a year of construction of the Extron electronic DMS 3600 item
- rules of operation, control and maintenance of the Extron electronic DMS 3600 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Extron electronic DMS 3600 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Extron electronic DMS 3600, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Extron electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Extron electronic DMS 3600.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Extron electronic DMS 3600 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Setup Guide 68-1829-50 Rev . C 09 13 DMS 1600, DMS 2000, DMS 3200, DMS 3600 Configurable Digital Video Matrix Switchers Matrix Switchers[...]
-
Page 2
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the FCC rules. The ClassA limits provide r easonable protection against harmful interference when the equipment is operated in a commercial envir onment. This equipment generates, uses, and can radiate radi[...]
-
Page 3
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents v Software Commands Commands are written in the fonts shown her e: ^A R Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C [01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03] E Y! * Y1& * Y2) * Y2# * Y2! CE } NOTE: For commands and examples of computer or device responses mentioned in this guide, the cha[...]
-
Page 4
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction 1 vi DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Contents Intr oduction WARNING : Risk of serious physical injury — The DMS ber optic I/O boards output continuous invisible light, which may be harmful to the eyes; use with caution. • Do not look into the ber optic cable connectors or [...]
-
Page 5
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction 2 3 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction About the DMS Matrix Switchers The DMS 1600, DMS 2000, DMS 3200, and DMS 3600 (see gure 1) are congurable matrix switchers that distribute DVI signals and DFX transmitter and receiver outputs and inputs. I/O boar ds route signal[...]
-
Page 6
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 5 4 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Introduction Installation This section describes installation of the DMS matrix switchers, including connections and features. T opics that are covered include: • Rear Panel • Front Panel Rear Panel I/O Board Configuration Overview See gur[...]
-
Page 7
6 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 7 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation ANAHEIM, CA RESET RS232/RS422 REMOTE LAN ACT LINK REDUNDANT PRIMARY PRIMARY POWER SUPPL Y REDUNDANT POWER SUPPL Y FAN ASSIMB LY FAN ASSIMB LY 100-240V 50-60Hz 2.5A MAX. 100-240V 50-60Hz 2.5A MAX. DISCONNECT BOTH POWER CORDS BEFORE SER[...]
-
Page 8
8 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation 9 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation e Remote port — If desired, connect a contr ol system or computer to the rear panel Remote RS-232/RS-422 port. RS-232 Function Pin Function 1 2 3 4 5 6 7 8 9 — Tx Rx — Gnd — — — — Not used Tr ansmit Receive Not used Grou[...]
-
Page 9
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations 11 10 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Installation Fr ont Panel Operations This section describes simple DMS matrix switcher operation from the front panel. T opics that are covered include: • Creating a Tie • Viewing Ties (and Muting Outputs) • Saving or Recalling a[...]
-
Page 10
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 13 12 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations Remote Contr ol This section describes using the remote contr ol features of the DMS matrix switchers to control the devices. T opics that are covered include: • Selected SIS Commands • Installing and Starting the Co[...]
-
Page 11
14 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 15 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Number of connections A switcher can have up to 200 simultaneous TCP connections, including all HTTP sockets and T elnet connections. When the connection limit is reached, the switcher accepts no new connections until some have [...]
-
Page 12
15 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command and Response T able for SIS Commands Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description NOTES : • Commands can be entered back-to-back in a string, with no spaces. For example: 1*1!02*02&003*003% . • The matrix switchers support 1-, 2-, and[...]
-
Page 13
16 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 17 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description EDID NOTE: In the commands below , the EDID data can come from either an active output or be set to a specied value. Assign EDID data to an i[...]
-
Page 14
18 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 19 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command ASCII Command (Host to Unit) Response (Unit to Host) Additional Description Channel mute commands Channel mute X@ *1B Vmt X@ *1 ] Mute output X@ (no signal is output). Channel unmute X@ *0B Vmt X@ *0 ] Unmute output X@ ([...]
-
Page 15
20 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control NOTE: X1! = Address nnn . nnn . nnn . nnn X1@ = DHCP 0 = off, 1 = on Command ASCII Command (host to unit) Response (unit to host) Additional Description IP and serial port setup Set IP address EX1! CI } Ipi X1!] Default: 192 . 168 . 254 . 254 Read IP address E CI } X1!] Set subnet mask EX[...]
-
Page 16
21 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Installing and Starting the Control Pr ogram Another way to operate the switcher is via the Windows ® -based Matrix Switchers Control Pr ogram. This program is contained on the Extr on Software Pr oducts DVD (included with the switcher) or on the website. Run this program on a PC connect[...]
-
Page 17
22 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 23 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 4. Follow the on-screen instructions. The installation program cr eates a C:Program FilesExtr onMatrix_Switchers directory and an “Extr on ElectronicsMatrix Switchers” gr oup folder . It installs the following four progr[...]
-
Page 18
24 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 25 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 4. If you selected IP [LAN] in step 2, the IP Connection window appears. Figure 12. IP Connection Window a. Examine the Matrix IP Address eld, which displays the last Matrix IP address enter ed. If necessary , enter the corre[...]
-
Page 19
26 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 27 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 5. Execute a ping command by entering ping followed by a space and the new IP address at the command pr ompt. For example: ping 10 . 13 . 197 . 7 C:>ping 10.13.197.7 Pinging 10.13.197.7 with 32 bytes of data: Reply from 10.1[...]
-
Page 20
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 29 28 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Maintenance and Modifications This section describes repairing and r econguring the DMS matrix switchers by replacing components. T opics that are covered include: • Removing and Installing an I/O Board or [...]
-
Page 21
30 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 31 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications ANAHEIM, CA RESET REMOTE RS-232/RS-422 LAN BI-LEVEL TRI-LEVEL ACT LINK 100-240V 50/60Hz 1.2A MAX. 100-240V 50/60Hz 1.2A MAX. REDUNDANT PRIMARY DISCONNECT BOTH POWER CORDS BEFORE SERVICIN G SWITCH [...]
-
Page 22
32 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 33 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications 3. Slide the power supply out of the chassis. 4. Orient the power supply module to be installed with the LED to the right. 5. Align the anges on the power supply module with the left and right [...]
-
Page 23
34 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Maintenance and Modifications[...]
-
Page 24
Extron W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of three years fr om the date of purchase. In the event of malfunction du ri ng the warranty period attributable directly to faulty workmanship and/or materials, Ext ron Electronics will, at its option, r epair or replace said produc[...]
-
Page 25
Extron USA Headquarters +800.633.9876 (Inside USA/Canada Only) Extron USA - W est Extr on USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 F AX +1.919.850.1001 F AX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.4050 F AX E xtron India 1800.3070.3777 (Inside India Only) +91-80 3055.3777 +91 80 3055 3737 F AX [...]