Extron electronic MKP 2000 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Extron electronic MKP 2000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Extron electronic MKP 2000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Extron electronic MKP 2000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Extron electronic MKP 2000 should contain:
- informations concerning technical data of Extron electronic MKP 2000
- name of the manufacturer and a year of construction of the Extron electronic MKP 2000 item
- rules of operation, control and maintenance of the Extron electronic MKP 2000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Extron electronic MKP 2000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Extron electronic MKP 2000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Extron electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Extron electronic MKP 2000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Extron electronic MKP 2000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    User ’ s Manual Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Extron Electronics, E urope Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 Extron Electronics, Asia 135 Joo Seng R oad, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6[...]

  • Page 2

    Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read In[...]

  • Page 3

    MKP 2000 Remote Control Panel • Quick Start Guide QS-1 Install and set up the MKP 2000 as follows: Step 1 T urn all of the equipment of f and disconnect it from the power source. Step 2 Install the cables to and from the control panel in a wall, podium, or desk. See Rear Panel and Side Panel Connections in chapter 2, Installation , for guidelines[...]

  • Page 4

    MKP 2000 Remote Control Panel • Quick Start Guide Quick Start Guide — MKP 2000, cont’d i MKP 2000 Remote Control Panel• Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the MKP 2000 Remote Control Panel ........... 1-2 RS-232 connection to the switcher ........................[...]

  • Page 5

    ii MKP 2000 Remote Control Panel • Table of Contents T able of Contents, cont’d MKP 2000 Remote Control Panel 1 Chapter One Intr oduction About the MKP 2000 Remote Control Panel 68-971-01 A 01 05 All trademarks mentioned in this manual are the pr operties of their r espective owners. Symbol definitions for MKP SIS commands .....................[...]

  • Page 6

    MKP 2000 Remote Control Panel • Introduction MKP 2000 Remote Control Panel • Introduction Introduction This manual provides installation and operation instructions for the Extron MKP 2000. About the MKP 2000 Remote Control Panel The MKP 2000 is a network-r eady remote contr ol panel that can control any Extr on matrix switcher . The MKP’s RS-[...]

  • Page 7

    MKP 2000 Remote Control Panel • Introduction MKP 2000 Remote Control Panel • Introduction Introduction 2 Chapter T wo Installation MKP Installation Overview UL Requirements for Wall Box Installation Installation Procedures Rear Panel and Side Panel Connections 1-4[...]

  • Page 8

    MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation 2-3 UL Requirements for W all Box Installation The following Underwriters Laboratories (UL) requirements pertain to the installation of the MKP 2000 into a wall or furniture (figure 2-1). MKP 200 0 4 5 6 1 23 7 8 9 B A C K 0 CANC EL INPUT OUTP[...]

  • Page 9

    MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d Preparing the site, installing the mud ring or wall box Choose a location that allows cable runs without interference. Allow enough depth for both the wall box and the cables. Y ou may need to install the cables into the wall, furnit[...]

  • Page 10

    MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d 2-6 7a . If you are using a mud ring , follow the directions, if any , that came with the mud ring to attach the clips that fasten the ring to the wall or furniture (figur e 2-3). T o meet the UL listing requir ements, this device mu[...]

  • Page 11

    MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d 3 . Mount the MKP’s faceplate to the mud ring or wall box with machine screws (figure 2-5). M K P 200 0 4 5 6 1 23 7 8 9 B A C K 0 CANC EL INPUT OUTPUT TAKE R Figure 2-5 — Mounting the MKP to the wall box 4 . Reconnect the power [...]

  • Page 12

    MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d Contr ol connections The MKP has two RS-232 ports; a Host port ( 1 ) and a Switcher port ( 2 ); and an Ethernet (LAN) port ( 3 ). An MKP contr ol panel can be dir ectly connected to any Extr on matrix switcher through the switcher ?[...]

  • Page 13

    MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d TP cable termination It is vital that your Ethernet cables be the correct cables, and that they be pr operly terminated with the correct pinout. Ethernet links use Category (CA T) 5e or CA T 6, unshielded twisted pair (UTP) or shield[...]

  • Page 14

    MKP 2000 Remote Control Panel • Installation Installation, cont’d MKP 2000 Remote Control Panel 3 Chapter Thr ee Local Operation Front Panel Controls and Indications Front Panel Operations Rear Panel Resets 2-14 Power supply wiring Figure 2-12 shows how to wir e the connector . P ower Supply Output Cord Direct Inser tion Connector 0.2” (5 mm)[...]

  • Page 15

    MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation 3-2 Front Panel Controls and Indications MKP 2000 456 123 789 BACK 0 CANCEL INPUT OUTPUT T AKE 2 6 3 5 4 1 7 BACK 0 CANCEL Figure 3-1 — MKP 2000 controls and indicators 1 0, 1 through 9 buttons — These buttons allow you to enter a[...]

  • Page 16

    MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d When an input or output outside the available range for this MKP or the connected matrix switcher is selected, the LED display shows N - A . V iewing the last input or output tied from the MKP Pr ess either the Input button [...]

  • Page 17

    MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d 1 9 21 6 8 .2 5 42 5 3 .. 2 5 52 5 5 .0 0 00 0 0 .. 0 0 00 0 0 .0 0 00 0 0 .. 0 0 00 0 0 . . . . . . . . . . . . . 0 0 00 0 0 .. SEC Pri INPUT OUTPUT TA K E OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT INPUT INPUT INPUT INPUT I[...]

  • Page 18

    MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d 3-8 Control panel security lockout (executive mode) The front panel security lockout limits the MKP’s front panel operation to input and output selection only (IP addr ess modification is locked). T o toggle the lock on an[...]

  • Page 19

    MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d MKP 2000 Remote Control Panel 4 Chapter Four SIS Operation RS-232 Links Ethernet Link Host-to-MKP Instructions MKP-Initiated (Unsolicited) Messages MKP Error Responses Using the Command/Response Table 3-10 Performing a hard r eset The hard reset function r estor es the MKP [...]

  • Page 20

    MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation RS-232 Links The MKP’s rear panel 3-pole, 3.5 mm, Host RS-232 connector (figur e 4-1) can be connected to the RS-232 serial port output of a host device such as a computer running the HyperT erminal utility , an RS-232 capable PDA, or a c[...]

  • Page 21

    MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d This message means that the switcher requires an administrator or user level passwor d before it will perform the commands entered via this link. The switcher r epeats the password message response for every entry other than a val[...]

  • Page 22

    MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d Symbol definitions for MKP SIS commands = CR/LF (carriage return/line feed) (0x0D 0A) • = space X1 = On/off status 0 = off/disable 1 = on/enable X2 = RS-232 port number 1 = host 2 = switcher X3 = n=–1= redirect serial port dat[...]

  • Page 23

    MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d Command/response table for MKP SIS commands (continued) Command ASCII Command Response Additional description (host to M K P ) (M K P to host) 4-8 Command/response table for MKP SIS commands Command ASCII Command Response Addition[...]

  • Page 24

    MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d Command/response table for MKP SIS commands (continued) Command ASCII Command Response Additional description (host to M K P ) (M K P to host) Command/response table for MKP SIS commands (continued) Command ASCII Command Response [...]

  • Page 25

    MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d MKP 2000 Remote Control Panel 4-14 5 Chapter Five HTML Operation Download the Startup Page System Status Page System Settings Page Port (RS-232) Settings Page Passwords Page Firmware Upgrade Page File Management Page Special Characters[...]

  • Page 26

    MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation 5-3 5-2 5 . Press the keyboard Enter key . The MKP checks to see if it is password protected. If the MKP is not password pr otected, proceed to step 7 . If the MKP is password pr otected, the MKP downloads the Enter Network Password page[...]

  • Page 27

    MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-5 5-4 System Status Page The System Status page (figure 5-2) provides an overall view of the status of the MKP , including various IP addresses, the status of the Host and Switch RS-232 ports, and the voltage. The System Stat[...]

  • Page 28

    MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-7 5-6 IP Settings section Unit Name field The Unit Name field contains the locally-assigned name of the MKP . This name field can be changed to any valid name, up to 24 alphanumeric characters. The following characters are in[...]

  • Page 29

    MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-9 5-8 Authorized inputs and authorized outputs Y ou can use the Authorized Inputs and Authorized Outputs drop boxes to narr ow the number of inputs and outputs that are controllable fr om the MKP . When creating ties fr om th[...]

  • Page 30

    MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-11 5-10 Passwords Page Access the Passwords page (figure 5-5) by clicking the Configuration tab and then the Passwords link on the left side of the System Settings page. System (IP) Settings Firmware Upgrade P or t Settings F[...]

  • Page 31

    MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-13 5-12 7 . Click the Browse button. An open file window appears (figure 5-7). Figure 5-7 — Firmware upgrade open file window 8 . Navigate to the folder where you saved the firmware upgrade file. Select the file. V alid fir[...]

  • Page 32

    MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d MKP 2000 Remote Control Panel 5-14 Special Characters The HTML language reserves certain characters for specific functions. The MKP will not accept these characters as part of its name, passwords, or locally cr eated file names. V alid file names: • Are a maximum of 24 uppe[...]

  • Page 33

    MKP 2000 Remote Control Panel • Reference Data MKP 2000 Remote Control Panel • Reference Data Reference Data A-3 A-2 Specifications Control/remote — keypad Extron remote key pad control . . (2) 3.5 mm, 3-pole captive screw connectors General External power supply ............... 100 VAC to 240 VAC, 50/60 Hz, external, autoswitchable; to 12 VD[...]

  • Page 34

    MKP 2000 Remote Control Panel • Reference Data MKP 2000 Remote Control Panel • Reference Data Reference Data , cont’d A-5 A-4 Mounting and Cabling Specifications Electrical box cutout Any standard box that meets the local electrical codes can be used, but boxes from dif ferent manufacturers can have differ ent size openings. Extr on recommend[...]

  • Page 35

    MKP 2000 Remote Control Panel • Reference Data Reference Data , cont’d Extron Comm-Link cable W i re specifications for Extron Comm-Link cable (figur e A-2) are as follows: A (red) = 18 A WG B (violet or blue) = 22 A WG (grouped and shielded) C (white) = 22 A WG D (Drain) = 24 A WG E (black) = 18 A WG Comm-Link cable was designed for use with M[...]